This article reports the experimental study on a concentrated photovoltaic thermal (PV/T) solar system. A nonimaging linear Fresnel lens was used as a solar concentrator to improve the density of solar energy on a PV/T collector surface. The PV/T collector consisted of a top copper cover and a serpentine channel in which water flowed. Eight pieces of monocrystalline PV cells were connected to one another in series and stuck on the top of the copper cover to produce electrical power. Water from a water storage tank flowed through the lower serpentine channel and removed heat to cool PV cells. The experimental studies were carried out on March 2016 in Shanghai, China. Results showed that the total effective utilization of solar energy was approximately 53% for the concentrated PV/T system. Although the electrical efficiency of PV cells decreased by approximately 34.7% for the PV/T system with a nonimaging linear Fresnel lens on March 4, 2016, the output power increased by 29% at the peak point. Another benefit was that the water storage tank can obtain high water temperature because the PV/T collector received high solar energy density by the linear Fresnel lens. The temperature increment in the water tank can reach 20°C, which was remarkably good to satisfy the daily demand of hot water.
16 July 2013 in Journal of Solar Energy Engineering
In order to create interior multiclimate zones suitable for plant cultivation in a solar chimney project proposed for the World Horticultural Exposition 2016 in China, the numerical investigation is performed to a solar chimney with 2 km radius and 1 km height. The simulation methodology is validated by experimental data. The impacts of inlet height and radius to interior thermal characteristics are evaluated. It is found that the temperature field is much similar when the inlet height decreases from 3.8 m to 0.5 m. With further decrease of the inlet height to 0.2 m, its impact to temperature field is significant. The temperature field is similar though the radius of solar chimney decreases from 2.0 km to 1.725 km. Further decrease to 1.13 km results in much lower temperature field as less radiate heat is obtained. The procedure of soil surface temperature calculation is also proposed to obtain the supplementary heat amount maintaining the required temperature for plant cultivation.
Reasonable flow channel designs play a significant role in improving the performance of proton exchange membrane fuel cells (PEMFC). The effect of the zigzag flow channels with three different numbers of turns on the performance of PEMFC was investigated in this paper. The polarization curves, molar concentration of oxygen and water, and power density were analyzed, and the numerical results showed that the overall performance of the zigzag flow channels was significantly better than that of the conventional parallel flow channel. With the increase of the number of turns from 3 to 9, the performance of PEMFC was gradually improved, the diffusion capacity of oxygen to the interface of the electrochemical reaction was also promoted, and the low oxygen concentration regions were gradually reduced. When the number of turns was 9, the current density of PEMFC was 8.85% higher than that of the conventional parallel channel at the operating voltage of 0.4 V, and the oxygen non-uniformity at the between gas diffusion layer (GDL) and catalyst layer (CL) interface was the minimum with a value of 0.51. In addition, the molar concentration of water in the channel also decreased. Due to the relatively large resistance of the zigzag flow channels, the maximum pressure drop of the zigzag flow channel was 263.5 Pa, which was also conducive to the improvement of the drainage effect of the conventional parallel flow channel. With the increase of the number of turns in the zigzag channel, the pressure drop and parasitic power density gradually increased. The 9-zigzag flow channel obtained the maximum pressure drop and net power density, which were 263.5 Pa and 2995.6 W/m2, respectively.