Yangyang Gao

Yangyang Gao


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2024 in Materials Research Express
Verified
Journal Article
Open access
YGYangyang Gao
Yangyang Gao
HLHuanjun La
Huanjun La
HMHaonan Min
Haonan Min
ZHZhenzhong Hou
Zhenzhong Hou
Hydrogels have demonstrated significant potential in wound dressings, owing to their adjustable water content, excellent biocompatibility, and other advantages. An ideal wound dressing requires absorbing exudate while maintaining mechanical properties to prevent secondary damage to the wound under external pressure. In this study, Polyacrylic Acid (PAA)/Chitosan (CS) double network hydrogels were prepared via radical polymerization, and the swelling ratio, compressive modulus, and other parameters were experimentally measured. A hyperelastic finite element model of the hydrogel was then established, and its rationality was validated by experiments. Based on the model, the impacts of CS content and dynamic water content on the compressive properties of PAA/CS hydrogels were analyzed. Tetracycline hydrochloride was loaded into PAA/CS hydrogels, the drug release performance and adhesion experiments were carried out. The results indicated that, compared with the hydrogels with 2.5% and 5% CS content, the hydrogel with 1% CS content had the highest swelling ratio, which was 1774%. Meanwhile, its equilibrium water content could attain 94.6%. When the water content varied within the range from 45% to 75%, the compressive strength of the hydrogel with 5% CS content ranged from 0.33 MPa to 1.22 MPa, similar to that of skin tissue. Additionally, the prepared drug-loaded PAA/CS hydrogels exhibited a drug release pattern approximately following the Korsmeyer-Peppas model within 7 days. They also exhibited remarkable adhesion to porcine skin and different substrate surfaces. This study provides a basis for the clinical application of PAA/CS double network hydrogels as wound dressings in the repair of infected wounds.

28 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
YGYangyang Gao
Yangyang Gao
TLTan Li
Tan Li
FMFanshu Meng
Fanshu Meng
ZHZhenzhong Hou
Zhenzhong Hou
CXChao Xu
Chao Xu
LYLaixia Yang
Laixia Yang
Personalised controlled drug delivery systems (CDDSs) can adjust drug concentration levels according to patient needs, which has enormous research prospects in precision medicine. In this study, the topological optimisation method was utilised in the structural design of a hydrogel CDDS to achieve a parameter-based adjustment of the drug average concentration in the hydrogel. A polyacrylamide/sodium alginate dual-network hydrogel was selected as a drug carrier, and tetracycline hydrochloride was used as a model drug. The topological optimisation model of the hydrogel CDDS was developed. The effects of the mesh size, target concentration, and volume factor on the optimised results were investigated. Hydrogel flow channel structures were obtained, which satisfied the different target concentrations. To verify the rationality of the optimisation model, in vitro drug release experiments were carried out. The results show that the hydrogel CDDS can control drug release within 7 days, and the drug release tends to follow zero-order release behaviour. The adjustable average concentration of tetracycline hydrochloride in hydrogel CDDS is recommended in the range of 20.79 to 31.04 mol/m3. This novel method provides a reference for personalised structure design of CDDS in the context of precision medicine.

18 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
KDKang Du
Kang Du
LYLaixia Yang
Laixia Yang
CXChao Xu
Chao Xu
Bin WangBin Wang
Bin Wang
YGYangyang Gao
Yangyang Gao
Nickel-based alloy Inconel 625, produced by the selective laser melting method, was studied experimentally for its mechanical performance under strain rate loading using Hopkinson bars. Both compression and tensile tests were carried out, with the former also being conducted at 500 °C. The strain rate was in the range of 300 to 3500 s−1 at ambient temperature, and 1200 to 3500 s−1 at the elevated temperature, respectively, for compression tests, and 900 to 2400 s−1 for tensile tests. Results show that the alloy has a strong rate sensitivity with the dynamic yield stress at 3500 s−1, almost doubling the quasistatic value. The test results also show that, even though the temperature elevation leads to material softening, the strain rate effect is still evidential with the dynamic compressive yield stress at the rate 103 s−1 and 500 °C still being higher than the quasistatic one at ambient temperature. It is also observed that dynamic tensile strengths are generally higher than those of compressive ones at room temperature.

1 December 2019 in International Journal of Simulation Modelling
Verified
Journal Article
Closed access
YGYangyang Gao
Yangyang Gao
CXC. Xu
C. Xu
LYL. Yang
L. Yang
BWB. Wang
B. Wang

11 May 2026 in Metals
Verified
Journal Article
Open access
PDF file
SLsuli li
suli li
ZGZhijie Guo
Zhijie Guo
YGYangyang Gao
Yangyang Gao
JGJing Guo
Jing Guo
To address issues such as thermal stress concentration in metal bone implants produced via high-energy beam direct additive manufacturing, a method was proposed to fabricate porous titanium scaffolds. This approach combined Fused Deposition Modeling (FDM) with a debinding–sintering process. Ti/ABS composite filaments with titanium volume fractions of 35%, 40%, and 45% were successfully developed via a single-screw extrusion process. Their feasibility in the FDM process was subsequently verified. The effects of different processing parameters on the forming quality and dimensional accuracy of the green bodies were investigated. After debinding and sintering the composite scaffolds prepared with optimized parameters, structurally intact porous titanium scaffolds were obtained. Microscopic characterization shows that the scaffold surface consists primarily of titanium, and the pore structure remains intact. Furthermore, compression tests were performed on three types of porous titanium scaffolds with different porosities. The results indicate that the combination of ABS/titanium alloy composite filaments, FDM technology, and debinding–sintering post-processing enables the high-quality and efficient production of porous titanium scaffolds. The elastic modulus of the resulting scaffolds ranges from 1.2 to 1.6 GPa, and the compressive strength is between 25.7 and 68.3 MPa. The elastic modulus matches that of human cancellous bone. Meanwhile, the compressive strength is significantly higher than that of cancellous bone and falls between the values for cancellous and cortical bone. These mechanical properties meet the requirements for human bone, providing a new approach for the manufacture of orthopedic implants.