The increased availability of commercially-available low-cost air quality sensors combined with increased interest in their use by citizen scientists, community groups, and professionals is resulting in rapid adoption, despite data quality concerns. We have characterized three out-the-box PM sensor systems under different environmental conditions, using field colocation against reference equipment. The sensor systems integrate Plantower 5003, Sensirion SPS30 and Alphasense OCP-N3 PM sensors. The first two use photometry as a measuring technique, while the third one is an optical particle counter. For the performance evaluation, we co-located 3 units of each manufacturer and compared the results against optical (FIDAS) and gravimetric (KFG) methods for a period of 7 weeks (28 August to 19 October 2020). During the period from 2nd and 5th October, unusually high PM concentrations were observed due to a long-range transport episode. The results show that the highest correlations between the sensor systems and the optical reference are observed for PM1, with coefficients of determination above 0.9, followed by PM2.5. All the sensor units struggle to correctly measure PM10, and the coefficients of determination vary between 0.45 and 0.64. This behavior is also corroborated when using the gravimetric method, where correlations are significantly higher for PM2.5 than for PM10, especially for the sensor systems based on photometry. During the long range transport event the performance of the photometric sensors was heavily affected, and PM10 was largely underestimated. The sensor systems evaluated in this study had good agreement with the reference instrumentation for PM1 and PM2.5; however, they struggled to correctly measure PM10. The sensors also showed a decrease in accuracy when the ambient size distribution was different from the one for which the manufacturer had calibrated the sensor, and during weather conditions with high relative humidity. When interpreting and communicating air quality data measured using low-cost sensor systems, it is important to consider such limitations in order not to risk misinterpretation of the resulting data.
We present a comprehensive study on the impacts and associated changes in costs resulting from the implementation of Environmental Speed Limits (ESLs), as a measure to reduce PM10 and associated health effects. We present detailed modelled emissions (i.e., CO2, NOx, PM2.5 and PM10), concentration levels (i.e., PM2.5 and PM10) and population exposure to PM2.5 and PM10 under three scenarios of ESL implementation for the Metropolitan Area of Oslo. We find that whilst emissions of NOx and CO2 do not seem to show significant changes with ESL implementation, PM10 emissions are reduced by 6-12% and annual concentration levels are reduced up to 8%, with a subsequent reduction in population exposure. The modelled data is used to carry out a detailed analysis to quantify the changes in private and social costs for the roads in Oslo where ESL are implemented today. This involves assessments related to human health, climate, fuel consumption, time losses and the incidence of traffic accidents. For a scenario using actual speed data from ESL implementation, our study shows a net benefit associated with the implementation of ESLs, whilst for a theoretical scenario with strict speed limit compliance we find a net increase in costs. This is largely due to variation in costs due to time losses between the scenarios, although uncertainties are high.