Gema Chamorro-Moriana

Dr. Gema Chamorro-Moriana

University of Seville, Spain. Research Group "Area of physiotherapy" CTS305
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2014 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
LRLucía Redondo-Alonso
Lucía Redondo-Alonso
GCGema Chamorro-Moriana
Gema Chamorro-Moriana
JJJosé-Jesús Jimenez-Rejano
José-Jesús Jimenez-Rejano
PLPatricio López-Tarrida
Patricio López-Tarrida
CRCarmen Ridao-Fernandez
Carmen Ridao-Fernandez
Chronic supraspinatus tendinopathy is a common clinical problem that causes functional and labor disabilities in the population. It is the most frequent cause of shoulder pain. This pathology may be frequently associated to the affectation of the long head of biceps tendon (LHBT), the main stabilizer of the glenohumeral joint together with the supraspinatus. The main aim of this work is to study the prevalence of lesions in LHBT associated to the chronic pathology of the supraspinatus tendon. A systematic review was carried out between May to July 2013 in the electronic databases: CINAHL, WOK, Medline, Scopus, PEDro, IME (CSIC) and Dialnet. The keywords used were: 1) in English: chronic, supraspinatus “long head of the biceps tendon”, biceps, rotator cuff, tendinosis, tendinopathy, evaluation, examination; 2) in Spanish: supraespinoso, biceps, tendinopatía. Inclusion criteria of the articles included subjects with a previously diagnosed chronic pathology of rotator cuff (RC) without previous surgery or any other pathologies of the shoulder complex. The total number of articles included in the study were five. The results show an epidemiological relationship between both tendons. The age of the subjects included in the review was between 35 and 80 years, and some of the studies seem to indicate that the tendinopathy is more frequent in men than in women. The sample size of the studies varies according to the design, the highest being composed of 229 subjects, and the minimum of 28. Not all the articles selected specify the diagnostic testing, though the ones most normally used are arthroscopy, ultrasound, magnetic resonance imaging and assessment tests. The percentage of associated lesions of LHBT and supraspinatus tendon is between 78.5% and 22%, with a major prevalence in the studies with a smaller sample. The review of literature corroborates an association between the chronic pathology of the supraspinatus tendon and LHBT due to the epidemiological data. In addition, some authors confirm the existence of an anatomical and functional relationship between LHBT and the supraspinatus tendon, the latter being part of the LHBT pulley.

1 September 2016 in Manual Therapy
Verified
Journal Article
Open access
JBJulie Bury
Julie Bury
MWMorgan West
Morgan West
GCGema Chamorro-Moriana
Gema Chamorro-Moriana
CLChris Littlewood
Chris Littlewood
Rotator cuff related shoulder pain (RCSP) is common with a range of conservative treatments currently offered. Evidence supporting superiority of one approach over another is lacking. Scapula focused approaches (SFA) are frequently prescribed and warrant investigation. To evaluate the effectiveness of SFA in RCSP. Systematic review of randomised controlled trials. An electronic search including MEDLINE, PEDro, ENFISPO to January 2016 was supplemented by hand searching. Randomised controlled trials were included; appraised using the PEDro scale and synthesised via meta-analysis or narratively, where appropriate. Four studies (n = 190) reported on pain and three studies (n = 122) reported on disability. Regarding pain, there was statistical but not clinically significant benefit of SFA versus generalised approaches (mean difference (VAS) 0.714; 95% CI 0.402-1.026) in the short term (<6 weeks); regarding disability, there was significant benefit of SFA versus generalised approaches (mean difference 14.0; 95% CI 11.2-16.8) in the short term (<6 weeks). One study (n = 22) reported disability at 3 months, which was not statistically significant. Evidence is conflicting from four studies relating to the effect of SFA on scapula position/movement. SFA for RCSP confers benefit over generalised approaches up to six weeks but this benefit is not apparent by 3 months. Early changes in pain are not clinically significant. With regards to scapula position/movement, the evidence is conflicting. These preliminary conclusions should be treated with significant caution due to limitations of the evidence base.

6 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
GCGema Chamorro-Moriana
Gema Chamorro-Moriana
AMAntonio José Moreno
Antonio José Moreno
JSJose Luis Sevillano
Jose Luis Sevillano
This systematic review synthesized and analyzed clinical findings related to the effectiveness of innovative technological feedback for tackling functional gait recovery. An electronic search of PUBMED, PEDro, WOS, CINAHL, and DIALNET was conducted from January 2011 to December 2016. The main inclusion criteria were: patients with modified or abnormal gait; application of technology-based feedback to deal with functional recovery of gait; any comparison between different kinds of feedback applied by means of technology, or any comparison between technological and non-technological feedback; and randomized controlled trials. Twenty papers were included. The populations were neurological patients (75%), orthopedic and healthy subjects. All participants were adults, bar one. Four studies used exoskeletons, 6 load platforms and 5 pressure sensors. The breakdown of the type of feedback used was as follows: 60% visual, 40% acoustic and 15% haptic. 55% used terminal feedback versus 65% simultaneous feedback. Prescriptive feedback was used in 60% of cases, while 50% used descriptive feedback. 62.5% and 58.33% of the trials showed a significant effect in improving step length and speed, respectively. Efficacy in improving other gait parameters such as balance or range of movement is observed in more than 75% of the studies with significant outcomes. Conclusion: Treatments based on feedback using innovative technology in patients with abnormal gait are mostly effective in improving gait parameters and therefore useful for the functional recovery of patients. The most frequently highlighted types of feedback were immediate visual feedback followed by terminal and immediate acoustic feedback.

16 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
JRJuan Gabriel Domínguez Romero
Juan Gabriel Domínguez Romero
JJJosé-Jesús Jimenez-Rejano
José-Jesús Jimenez-Rejano
CRCarmen Ridao-Fernandez
Carmen Ridao-Fernandez
GCGema Chamorro-Moriana
Gema Chamorro-Moriana
(1) Background: Rotator cuff (RC) tendinopathy causes pain and functional limitation of the shoulder. Physical exercises are effective therapies but there is no consensus on which exercise programme is the most appropriate. Objective: To analyze and compare the effectiveness of different intervention modalities-based exclusively on physical exercise muscle-development programs to improve shoulder pain and function in RC tendinopathy. (2) Methods: Systematic review (PRISMA) through a search in PubMed, WOS, PEDro, Cinahl, Scopus and Dialnet. The PEDro Scale and the Cochrane Risk of Bias analyzed the methodological quality. A pre-established table collected data on: patients, interventions, outcome measures and results. A narrative synthesis of the results was conducted. (3) Results: eight articles were selected (Cochrane: low risk of bias; PEDro: good quality). All assessed programs were effective. Only one study found statistically and clinically significant differences in favour of eccentric training. The exercises used were: eccentric/concentric/conventional, open/closed kinetic chain, with/without co-activation of glenohumeral muscle, with/without pain, and in clinic/at home. (4) Conclusions: All exercise programs were effective in RC tendinopathy, improving pain and shoulder function. No solid results were obtained when the interventions were compared due to their heterogeneity. Patients perception assessment tools were the most widely used. Amount of load applied should be considered.

31 August 2021 in Children
Verified
Journal Article
Open access
PDF file
PGPaula Rodriguez Gonzalez
Paula Rodriguez Gonzalez
VPVeronica Perez-Cabezas
Veronica Perez-Cabezas
GCGema Chamorro-Moriana
Gema Chamorro-Moriana
CMCarmen Ruiz Molinero
Carmen Ruiz Molinero
AVAna María Vazquez-Casares
Ana María Vazquez-Casares
GGGloria Gonzalez-Medina
Gloria Gonzalez-Medina
The aim of this study was to identify and to assess the best evidence currently available on the effectiveness of oral sensory-motor stimulation in preterm infants in the neonatal intensive care unit. We performed a systematic review following the Preferred Reporting Items for Systematic Reviews (PRISMA) statements. The search was conducted using the Pubmed, Web of Science (WOS), PEDro and Scopus databases. Clinical trials were reviewed and PEDro rating scale was used to assess the methodological quality of these studies. Results: 1267 studies were found and 11 were relevant and included in this review. Improvements were obtained in achieving independent feeding, maturation of the sucking pattern, transition to full feeding, motor function and length of hospital stay in most studies. Conclusions: there is evidence to support the benefits of the use of oral sensorimotor stimulation to achieve independent oral feeding in preterm infants, thereby reducing their stay in the Neonatal Intensive Care Unit.

10 February 2022 in Annals of Physical and Rehabilitation Medicine
Verified
Journal Article
Open access
GCGema Chamorro-Moriana
Gema Chamorro-Moriana
VPVeronica Perez-Cabezas
Veronica Perez-Cabezas
FEFernando Espuny-Ruiz
Fernando Espuny-Ruiz
DTDolores Torres-Enamorado
Dolores Torres-Enamorado
CRCarmen Ridao-Fernandez
Carmen Ridao-Fernandez
Functional rating scales allow clinicians to document and quantify alterations and progression of recovery processes. There is neither awareness of numerous knee scales nor are they easy to find or compare to select the most suitable. We aimed to compile validated knee functional rating tools and analyze the methodological quality of their validation studies. Also, we aimed to provide an operational document of the outcome measures addressing descriptions of parameters, implementations, instructions, interpretations and languages, to identify the most appropriate for future interventions. A systematic review involved a search of PubMed, Web of Science, CINAHL, Scopus, and Dialnet databases from inception through September 2020. The main inclusion criteria were available functional rating scales/questionnaires/indexes for knees and validation studies. Methodological quality was analyzed with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) and COnsensus-based Standards for the selection of health Measurement Instruments Risk of Bias (COSMIN-RB). We selected 73 studies. The studies investigated 41 knee rating tools (general, 46%, and specific, 54%) and 71 validations, including 29,742 individuals with knee disorders. QUADAS-2 obtained the best results in patient selection and index test (applicability section). COSMIN-RB showed the highest quality in construct validity (most analyzed metric property). The specific tools were mainly designed for prosthesis and patellofemoral and anterior cruciate ligament injuries. More considered issues were specific function (93%), especially gait, pain/sensitivity (81%), and physical activity/sports (56%). We conducted a necessary, useful, unlimited-by-time and feasible compilation of validated tools for assessing knee functional recovery. The methodological quality of the validations was limited. The best validations were for the Copenhagen Knee Range of Motion Scale in osteoarthritis and arthroplasties, Knee Outcome Survey Activities of Daily Living and Lysholm Knee Score for general knee disorders and the Tegner Activity Score for anterior cruciate ligament injuries. The operational document for the scales provides necessary data to identify the most appropriate.