You Jeong Jeong

Dr. You Jeong Jeong


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Tingting ZhangTingting Zhang
Tingting Zhang
YJYou Jeong Jeong
You Jeong Jeong
PCPark Dong Choon
Park Dong Choon
Tong In OhTong In Oh
Tong In Oh
As regular cervical cancer screening becomes more common, the detection of cervical intraepithelial neoplasia (CIN) is increasing. We proposed a noninvasive and low-cost multi-channel electrical impedance spectroscopy (EIS) and probe with multiple active electrodes for screening CIN. Compared with four-electrode probes for impedance spectroscopy, the multiple active electrodes facilitated more flexible combination of current injection and voltage measurement, which allowed well-designed measurement protocols for focused sensitivity underneath the large size of the probe. Furthermore, the multiple active electrodes reduced the negative effects of the cabling between the system and probe inserted into the cervix. After presenting the basic performance, the EIS probe was tested by three different experimental phantoms using four different materials of electrical properties. The corresponding experimental results were presented to prove the functionality of the EIS probe and characterize the electrical properties at a wide range of frequencies from 0.625 to 100 kHz. It had high sensitivity underneath the surface of the probe and a rapidly decreased outer. Furthermore, we verified the frequency-dependent impedance changes using the giant vesicle phantoms with different amounts of extra- and intra-fluids separated by the insulating membranes. This study facilitates the feasibility into clinical practice for identifying CIN in the future.

24 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MRMohammad Shamim Reza
Mohammad Shamim Reza
LJLu Jin
Lu Jin
YJYou Jeong Jeong
You Jeong Jeong
Tong In OhTong In Oh
Tong In Oh
HKHongdoo Kim
Hongdoo Kim
KKKap Jin Kim
Kap Jin Kim
This study aims to find base materials for dry electrode fabrication with high accuracy and without reducing electrode performance for long-term bioelectric potential monitoring after electroless silver plating. Most applications of dry electrodes that have been developed in the past few decades are restricted by low accuracy compared to commercial Ag/AgCl gel electrodes, as in our previous study of PVDF-based dry electrodes. In a recent study, however, nanoweb-based chlorinated polyisoprene (CPI) and poly(styrene-b-butadiene-b-styrene) (SBS) rubber were selected as promising candidates due to their excellent elastic properties, as well as their nanofibril nature, which may improve electrode durability and skin contact. The electroless silver plating technique was employed to coat the nanofiber web with silver, and silver nanoweb(AgNW)-based dry electrodes were fabricated. The key electrode properties (contact impedance, step response, and noise characteristics) for AgNW dry electrodes were investigated thoroughly using agar phantoms. The dry electrodes were subsequently tested on human subjects to establish their realistic performance in terms of ECG, EMG monitoring, and electrical impedance tomography (EIT) measurements. The experimental results demonstrated that the AgNW dry electrodes, particularly the SBS-AgNW dry electrodes, performed similarly to commercial Ag/AgCl gel electrodes and were outperformed in terms of long-term stability.

14 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Tong In OhTong In Oh
Tong In Oh
MKMin Ji Kang
Min Ji Kang
YJYou Jeong Jeong
You Jeong Jeong
TZTingting Zhang
Tingting Zhang
SYSeung Geun Yeo
Seung Geun Yeo
PCPark Dong Choon
Park Dong Choon
The successful management of cervical intraepithelial neoplasia (CIN) with proper screening and treatment methods could prevent cervical cancer progression. We propose a bioimpedance spectroscopic measurement device and a multi-electrode probe as an independent screening tool for CIN. To evaluate the performance of this screening method, we enrolled 123 patients, including 69 patients with suspected CIN and 54 control patients without cervical dysplasia who underwent a hysterectomy for benign disease (non-CIN). Following conization, the electrical properties of the excised cervical tissue were characterized using an electrical bioimpedance spectroscopy-based multi-electrode probe. Twenty-eight multifrequency voltages were collected through the two concentric array electrodes via a sensitivity-optimized measurement protocol based on an electrical energy concentration method. The electrical properties of the CIN and non-CIN groups were compared with the results of the pathology reports. Reconstructed resistivity tended to decrease in the CIN and non-CIN groups as frequency increased. Reconstructed resistivity from 625 Hz to 50 kHz differed significantly between the CIN and non-CIN groups (p < 0.001). Using 100 kHz as the reference, the difference between the CIN and non-CIN groups was significant. Based on the difference in reconstructed resistivity between 100 kHz and the other frequencies, this method had a sensitivity of 94.3%, a specificity of 84%, and an accuracy of 90% in CIN screening. The feasibility of noninvasive CIN screening was confirmed through the difference in the frequency spectra evaluated in the excised tissue using the electrical bioimpedance spectroscopy-based multi-electrode screening probe.

21 October 2026 in Kidney Research and Clinical Practice
Verified
Journal Article
Open access
PDF file
YJYoosun Joo
Yoosun Joo
YJYou Jeong Jeong
You Jeong Jeong
JMJin Won Mok
Jin Won Mok
YMYoungyoon Moon
Youngyoon Moon
SJSu Woong Jung
Su Woong Jung
JMJu-Young Moon
Ju-Young Moon