Alberto Cuocolo

Prof. Alberto Cuocolo

University of Naples Federico II, Naples, Campania, Italy
orcid

Research Focus & Metrics

Academic Career Length

44Years (1983-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2005 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
BHB. Hesse
B. Hesse
KTK. Tägil
K. Tägil
Alberto CuocoloAlberto Cuocolo
Alberto Cuocolo
CAC. Anagnostopoulos
C. Anagnostopoulos
MBM. Bardiés
M. Bardiés
BEB. van Eck-Smit
B. van Eck-Smit

1 January 1991 in Circulation
Verified
Journal Article
Closed access
RBR O Bonow
R O Bonow
VDV Dilsizian
V Dilsizian
Alberto CuocoloAlberto Cuocolo
Alberto Cuocolo
SBS L Bacharach
S L Bacharach
In patients with chronic coronary artery disease and left ventricular dysfunction, the distinction between ventricular dysfunction arising from myocardial fibrosis and ischemic, but viable, myocardium has important clinical implications. By positron emission tomography (PET), enhanced fluorine-18-labeled fluorodeoxyglucose (FDG) uptake in myocardial segments with impaired function and reduced blood flow is evidence of myocardial viability. Reinjection of thallium-201 at rest immediately after stress-redistribution imaging may also provide evidence of myocardial viability by demonstrating thallium uptake in regions with apparently "irreversible" defects. To compare these two methods, we studied 16 patients with chronic coronary artery disease and left ventricular dysfunction (ejection fraction, 27 +/- 9%), all of whom had irreversible defects on standard exercise-redistribution thallium single-photon emission computed tomography (SPECT) imaging. Thallium was reinjected immediately after the redistribution study, and SPECT images were reacquired. The patients also underwent PET imaging with FDG and oxygen-15-labeled water. A total of 432 myocardial segments were analyzed from comparable transaxial tomograms, of which 166 (38%) had irreversible thallium defects on redistribution images before reinjection. FDG uptake was demonstrated in 121 (73%) of these irreversible defects. Irreversible defects were then subgrouped according to the degree of thallium activity, relative to peak activity in normal regions. Irreversible defects with only mild (60-85% of peak activity) or moderate (50-59% of peak) reduction in thallium activity were considered viable on the basis of FDG uptake in 91% and 84% of these segments, respectively. In contrast, in irreversible defects with severe reduction in thallium activity (less than 50% of peak), FDG uptake was present in 51% of segments. In such severe defects, an identical number of segments (51%) demonstrated enhanced uptake of thallium after reinjection. In these severe "irreversible" defects, data on myocardial viability were concordant by the two techniques in 88% of segments, with 45% identified as viable and 43% identified as scar on both PET and thallium reinjection studies. These observations suggest that thallium imaging can be used to identify viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction. Most irreversible defects with only mild or moderate reduction in thallium activity represent viable myocardium as confirmed by FDG uptake.(ABSTRACT TRUNCATED AT 400 WORDS)

8 January 2014 in European Heart Journal
Verified
Journal Article
Open access
PDF file
EPEugenio Picano
Eugenio Picano
EVEliseo Vano
Eliseo Vano
MRMadan M. Rehani
Madan M. Rehani
Alberto CuocoloAlberto Cuocolo
Alberto Cuocolo
LMLluis Mont
Lluis Mont
LBLuigi P. Badano
Luigi P. Badano
The benefits of cardiac imaging are immense, and modern medicine requires the extensive and versatile use of a variety of cardiac imaging techniques. Cardiologists are responsible for a large part of the radiation exposures every person gets per year from all medical sources. Therefore, they have a particular responsibility to avoid unjustified and non-optimized use of radiation, but sometimes are imperfectly aware of the radiological dose of the examination they prescribe or practice. This position paper aims to summarize the current knowledge on radiation effective doses (and risks) related to cardiac imaging procedures. We have reviewed the literature on radiation doses, which can range from the equivalent of 1–60 milliSievert (mSv) around a reference dose average of 15 mSv (corresponding to 750 chest X-rays) for a percutaneous coronary intervention, a cardiac radiofrequency ablation, a multidetector coronary angiography, or a myocardial perfusion imaging scintigraphy. We provide a European perspective on the best way to play an active role in implementing into clinical practice the key principle of radiation protection that: ‘each patient should get the right imaging exam, at the right time, with the right radiation dose’.

21 August 2015 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
HVHein J. Verberne
Hein J. Verberne
WAWanda Acampa
Wanda Acampa
CAConstantinos Anagnostopoulos
Constantinos Anagnostopoulos
JBJim Ballinger
Jim Ballinger
FBFrank Bengel
Frank Bengel
BHBirger Hesse
Birger Hesse
Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: https://eanm.org/wp-content/uploads/2025/04/2015_myocardial_perfusion.pdf.

1 March 1990 in Circulation
Verified
Journal Article
Closed access
PDF file
Alberto CuocoloAlberto Cuocolo
Alberto Cuocolo
FSF L Sax
F L Sax
JBJ E Brush
J E Brush
BMB J Maron
B J Maron
SBS L Bacharach
S L Bacharach
RBR O Bonow
R O Bonow
Left ventricular ejection fraction is normal at rest but may respond abnormally to exercise in many patients with essential hypertension. To assess the determinants of the abnormal ejection fraction response to exercise, we performed radionuclide angiography at rest and during exercise in 41 hypertensive patients without coronary artery disease. In 22 patients (group 1), the ejection fraction increased more than 5% during exercise; in the other 19 patients (group 2), the ejection fraction either increased by less than 5% or decreased with exercise. Left ventricular diastolic filling was impaired at rest in patients in group 2 compared with group 1, with reduced peak filling rate (2.5 +/- 0.4 vs. 3.1 +/- 0.7 end-diastolic volume/sec; p less than 0.01) and prolonged time to peak filling rate (175 +/- 28 vs. 153 +/- 22 msec; p less than 0.01). Impaired diastolic filling in group 2 was associated with less augmentation in end-diastolic volume during exercise compared with group 1 (p less than 0.01). These observations were not dependent on the threshold value that was arbitrarily chosen to define an abnormal ejection fraction response, as there were significant correlations for the entire group between the magnitude of change in ejection fraction with exercise and both the resting peak filling rate (r = 0.46) and the change in end-diastolic volume with exercise (r = 0.62).(ABSTRACT TRUNCATED AT 250 WORDS)

1 March 2016 in Radiology
Verified
Journal Article
Closed access
OCOnofrio Antonio Catalano
Onofrio Antonio Catalano
MGMichael S. Gee
Michael S. Gee
ENEmanuele Nicolai
Emanuele Nicolai
FSFrancesco Selvaggi
Francesco Selvaggi
Gianluca PellinoGianluca Pellino
Gianluca Pellino
MSMarco Salvatore
Marco Salvatore
PET/MR enterography represents a new imaging tool for the noninvasive differentiation of fibrotic strictures from inflammatory strictures in Crohn disease. PurposeTo retrospectively evaluate positron emission tomography (PET)/magnetic resonance (MR) enterography for the differentiation of fibrotic strictures from inflammatory strictures in patients with Crohn disease.Materials and MethodsThis HIPAA–compliant retrospective study was approved by the institutional review board. Patients gave their written informed consent for study enrollment. PET/MR enterography images were evaluated in 19 patients with Crohn disease who had strictures that underwent surgical resection with pathologic confirmation. Two radiologists and a nuclear medicine physician in consensus evaluated the following bowel wall PET/MR enterography biomarkers: signal intensity (SI) on T2-weighted images, apparent diffusion coefficient (ADC), PET maximum standardized uptake value (SUVmax), SI on T2-weighted images × SUVmax, and ADC × SUVmax values at levels that corresponded to pathologic specimens. MR, PET, and hybrid PET/MR biomarkers were compared, and the performance for differentiation of i...