Zsolt Cimer

Dr. Zsolt Cimer

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
ZCZsolt Cimer
Zsolt Cimer
GVGyula Vass
Gyula Vass
AZAttila Zsitnyányi
Attila Zsitnyányi
LKLajos - Kátai-Urbán
Lajos - Kátai-Urbán
As a result of economic development and an increase in the volume of industrial production, the use of dangerous substances is increasing despite the fact that most industrial facilities are committed to the principles of environmental protection and sustainable development. Protection of human health and the environment is ensured at the local level by the local safety system. Major accidents typically have an off-site impact that also affects the general public. The most significant asymmetric event is when toxic substances are release into a populated area following a major accident. Early warning systems can significantly reduce the harmful consequences of major accidents that may occur. The operation of a reliable and effective chemical monitoring and public alarm system can be used as a basic device of defence. This ultimately means restoring the symmetry of the local safety system. It was an important scientific objective in Hungary to identify the facilities endangering the population where it is necessary to install chemical monitoring and early warning external protection systems. In this context, the main objective of this study was to present dangerous plant identification methodology and to analyse and evaluate the results of the application of this methodology.

31 July 2023 in Fire
Verified
Journal Article
Open access
PDF file
LKLajos - Kátai-Urbán
Lajos - Kátai-Urbán
ZCZsolt Cimer
Zsolt Cimer
ÉLÉva Eszter Lublóy
Éva Eszter Lublóy
The recent expansion of logistics capacities entails the installation of chemical warehouses, which operations increase the occurrence of compartment fires involving flammable dangerous substances. The aim of this research was to compare and analyze the fire behavior of beams made of different structural materials but with the same load capacity. It is assumed that wooden beams, which are less commonly used in industrial facilities, may have a similar or even better load-bearing capacity in case of a fire than the generally used steel beams. The authors—based on the relevant EU standards—performed load capacity calculations of three beams prepared from different materials under the influence of fire and analyzed the changes in the material properties. Then, they examined the possibility of reinforcing the beams with carbon fiber lamellae and proposed additional fire protection requirements. The test results not only proved the different degrees of fire resistance of various building materials in the event of a fire and after their reinforcement but also suggested the application of special technical, prevention and response measures for the safe storage of dangerous substances. The study outputs enable warehouse designers, operators and safety experts to ensure a higher fire safety level for chemical warehouses.

1 September 2023 in Fire
Verified
Journal Article
Open access
PDF file
MKMaxim Kátai-Urbán
Maxim Kátai-Urbán
TBTibor Bíró
Tibor Bíró
LKLajos - Kátai-Urbán
Lajos - Kátai-Urbán
FVFerenc Varga
Ferenc Varga
ZCZsolt Cimer
Zsolt Cimer
Major accidents involving flammable substances can lead to significant environmental damage. The operators of chemical warehouses—in order to prevent and mitigate harmful environmental impacts—based on fire prevention strategies should apply “firewater pollution prevention” (FPP) measures. The identification of affected warehouses already in operation is an important law enforcement task. Therefore, the authors—based on the assessment of firewater run-off scenarios—propose a simple and easy-to-use dangerous establishment identification procedure and methodology based on event tree analysis and indexing preliminary risk analysis approaches. Two independent expert groups validated—in the case of 10 facilities—the index components of the approach. The testing of the applicability of the approach took place in parallel with the analyses of the Hungarian operator’s practice. The research results—covering the inspection of 24 facilities—can assist the operators in the effective and unified implementation of FPP measures. In the case of 14 facilities, it was necessary to introduce FPP measures, which highlight the need to improve the law enforcement compliance of identified operators. The investigation results can also contribute to increases in the fire and environmental safety performance of chemical warehouses, which ensures a higher level of environmental protection and people’s health near chemical warehouses.

9 March 2023 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Open access
PDF file
ÉLÉva Eszter Lublóy
Éva Eszter Lublóy
DMDiána Tímea Mészáros
Diána Tímea Mészáros
LTLajos Gábor Takács
Lajos Gábor Takács
ZCZsolt Cimer
Zsolt Cimer
HNHorváth Norbert
Horváth Norbert
This paper aims to discover how organic wood preservatives containing different fungicides and insecticides used to protect wood against fungal and insect pests affect the fire performance and combustion properties of wood materials commonly used in the domestic wood and construction industry. The aim of this article was to investigate the charring depth. From the point of view of the loss of load-bearing capacity of the wood, only the charring depth matters, since the reduction of the load-bearing capacity will be determined by the reduction of the cross section of the wood. We examined the effects of wood preservatives applied to undamaged samples of Scots pine and Norway spruce conditioned under normal climate conditions. The test samples underwent a second treatment application after which we examined the effect of different preservative combinations. Seven treatment mixtures were selected from the organic solvent and water-based wood preservatives available on the domestic market. The soaking experiments demonstrated that the preservative impregnation of Norway spruce differs significantly from that of Scots pine, which affected the comparability of the test results. We have experimentally investigated the moisture content, the loss of mass and we have calculated the char depth. Adhering to the MSZ 9607–1:1983 standard, the Linder method was performed to analyze the wood and wooden-based construction products used in construction. The effect of the different treatment materials was more significantly detectable when analyzing the size of the surface burn patterns. The Scots pine specimens suffered much greater surface burn than the Norway spruce specimens did, regardless of the type of preservative used. The higher body density, resin content (1–10%) and higher initial moisture content of Scots pine caused it to bend and, therefore, to burn better.

30 November 2023 in Műszaki Katonai Közlöny
Verified
Journal Article
Open access
PDF file
MKMaxim Kátai-Urbán
Maxim Kátai-Urbán
ZMZoltán Mesics
Zoltán Mesics
LPLászló Pimper
László Pimper
ZCZsolt Cimer
Zsolt Cimer
A veszélyes anyagok tárolására szolgáló logisztikai létesítmények biztonságának megteremtéséhez a telephely üzemeltetőjének számos katasztrófavédelmi, környezetvédelmi és kémiai biztonsági szabályt kell figyelembe vennie. A létesítményekben esetlegesen bekövetkező balesetek vagy események az ott tárolt veszélyes anyagok kiszabadulása révén súlyosan veszélyeztethetik a környezetet és a környezetben élőket. Jelen tanulmányban a szerzők a logisztikai raktárakban tárolt veszélyes anyagok fogalmi értelmezését követően vizsgálják a súlyos baleseti esemény során kibocsátott veszélyes anyagok környezetre gyakorolt hatásait, különös tekintettel a környezetre veszélyes mérgező égéstermékekre, illetve a baleset-elhárításkor alkalmazott oltóhabokra. A cikk másik részében a szerzők áttekintik a súlyos balesetkor keletkező szennyezett oltóvíz mennyiségének számítására használt, nemzetközileg elfogadott eljárásokat.

21 June 2021 in Journal of Structural Fire Engineering
Verified
Journal Article
Closed access
ÉLÉva Eszter Lublóy
Éva Eszter Lublóy
LTLajos Gábor Takács
Lajos Gábor Takács
DEDavid Istvan Enczel
David Istvan Enczel
ZCZsolt Cimer
Zsolt Cimer
Purpose: The fire safety of structures is an existing and important design aspect, which is assured by strict regulations. As a means to adhere to the strict requirements, fire protection has become a core problem. It is particularly difficult to comply with these regulations in the case of timber, which is a combustible material. These problems could be solved by enveloping the wood in fire retardant materials. MSZ EN 1995-1-2 currently does not take into consideration the fire-retardant materials charring rate under fire exposure.Design/methodology/approach: However, currently these fire retardants are proving to be reliable and depending on their application can achieve better reaction-to-fire classifications. During the research, the authors used five different fire-retardant materials on three different types of wood and tested their behaviours in a laboratory. When selecting them, it was important to choose the species that are most commonly used in the building industry but which have significantly different densities. Our choice fell upon spruce (360 kg/m3), Scots pine (540 kg/m3) and oak (650 kg/m3). During the tests, we examined the weight reduction and the process of burning on the specimens treated with the fire retardant material. In addition, the authors also performed tests by derivatography on both untreated and treated specimen.Findings: The question is whether the effects of the fire retardants should be taken into consideration when calculating the extent of the burn. The Eurocode (MSZ EN 1995-1-2) does not provide any opinions. On the market, there are manufacturers who are already discussing the possibilities of reducing the burn rate during the qualification of paints. In this paper, based on the results we received, we discuss the beneficial effects of the fire retardants which can be taken into account while measuring cross-sections.Originality/value: By using fire retardants, a high proportion of cross-sectional area gain is only possible in case of small cross-sections; therefore, it is advisable to use them here as well. This can be effective for example in many smaller cross-sections, when there is a little space and therefore requires a small cross-section. Thus, if a larger cross-section without protection is not possible, it can be replaced by a smaller cross section, treated with a fire retardant.