Ragai Matta

Prof. Dr. Ragai Matta

Friedrich-Alexander-University of Erlangen-​Nürnberg, Erlangen, Germany
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2019 in Journal of Prosthodontics
Verified
Journal Article
Open access
PDF file
CMConstantin Motel
Constantin Motel
EKElena Kirchner
Elena Kirchner
WAWerner Adler
Werner Adler
MWManfred Wichmann
Manfred Wichmann
RMRagai Matta
Ragai Matta
Purpose: Sufficient data are not currently available on how the various geometries of scan bodies and different scan strategies affect the quality of digital impressions of implants. The purpose of this study was to present new data on these two topics and give clinicians a basis for decision making.Materials and Methods: A titanium master model containing three Nobelreplace Select™ implants (Nobelbiocare Services AG, Zurich, Switzerland) was digitized using an ATOS industrial noncontact scanner. Digitization was repeated three times with different types of scan bodies integrated into the implants: ELOS A/S, nt‐trading GmbH, and TEAMZIEREIS GmbH. These three scans served as virtual master models. The titanium master model was then scanned with the TRIOS3© digital intraoral scanner (ELOS A/S, Copenhagen, Denmark), which was used for two different scanning strategies. Strategy A was a one‐step procedure that included both the titanium master model and the integrated scan bodies. Strategy B comprised two steps. First, a digital overlay was performed with a scan of the titanium master model without integrated scan bodies. A second scan was performed with the titanium master model and integrated scan bodies. By repeating both strategies 10 times for each type of scan body, 60 scans were generated and the corresponding standard tessellation language data sets overlaid with the corresponding virtual master model. Deviations in the resulting superimpositions were calculated and evaluated separately in the individual axes (x, y, z) and in three‐dimensional space (Euclidean distance). Statistical evaluation was performed using the R‐project software. Level of significance was determined at p ≤ 0.05.Results: With regard to the geometry of the scan bodies, strategy A significantly influenced the accuracy of the digital implant impression in regards to Euclidean distance (p = 0.003). No significant difference was found for strategy B in this context. Comparing the two scan strategies revealed that strategy A achieved significantly higher accuracy overall (p = 0.031).Conclusion: The quality of digital intraoral impressions seems to be influenced by both the geometry of the scan body and the scan strategy. For clinical practice, the one‐step scan strategy seems beneficial. Furthermore, the scan bodies of ELOS A/S showed a potential clinical advantage.

1 November 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
JRJohannes Matthias Ries
Johannes Matthias Ries
CGChristian Grünler
Christian Grünler
MWManfred Wichmann
Manfred Wichmann
RMRagai Matta
Ragai Matta

1 June 2017 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
RMRagai Matta
Ragai Matta
BBBastian Bergauer
Bastian Bergauer
WAWerner Adler
Werner Adler
MWManfred Wichmann
Manfred Wichmann
HNHans-Joachim Nickenig
Hans-Joachim Nickenig

1 April 2017 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
RMRagai Matta
Ragai Matta
WAWerner Adler
Werner Adler
MWManfred Wichmann
Manfred Wichmann
SHSiegfried Martin Heckmann
Siegfried Martin Heckmann

13 February 2023 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
SASabrin Abu‐Hossin
Sabrin Abu‐Hossin
YOYonca Onbasi
Yonca Onbasi
LBLara Berger
Lara Berger
FTFlorian Troll
Florian Troll
WAWerner Adler
Werner Adler
RMRagai Matta
Ragai Matta
Objective: In dental restorations, color determination is very important for achieving esthetic results. The aim of this study was to compare visual shade selection using digital methods and to assess the repeatability of the utilized intraoral scanners.Materials and methods: In 31 probands, tooth color was determined on teeth 11, 13, and 16. Shade selection was performed visually by a dentist and digitally using Trios 3 and Cerec Omnicam. Three measurements were performed to determine the repeatability of intraoral scanners. Fleiss' κ was used for statistical evaluation of the repeatability and Cohen's κ was used for comparison of methods.Results: The visual method showed only slight agreement with Trios 3 (Cohen's κ: 0.198) and Cerec Omnicam (Cohen's κ: 0.115). Moderate agreement was found between Trios 3 and Cerec Omnicam (Cohen's κ: 0.452). In terms of repeatability, Trios 3 scored higher overall than Cerec Omnicam (Fleiss' κ: 0.612 vs. 0.474).Conclusion: Intraoral scanners can facilitate the workflow in clinical practice. They are a good supplement for color determination, but should additionally be confirmed by the visual method. Clinical significance: The use of digital instruments is increasingly being preferred over conventional treatments. Therefore, it is essential to continuously improve the accuracy of intraoral scanners for color selection in order to offer an alternative to visual methods.

29 December 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YOYonca Onbasi
Yonca Onbasi
SASabrin Abu-Hossin
Sabrin Abu-Hossin
MPMaria Paulig
Maria Paulig
LBLara Berger
Lara Berger
MWManfred Wichmann
Manfred Wichmann
RMRagai Matta
Ragai Matta
The aim of this study was to compare the trueness of complete- and partial-arch impressions obtained using conventional impression materials and intraoral scanners in vivo. Full-arch impressions were taken using polyether and polyvinylsiloxane. Gypsum casts were digitized using a laboratory scanner (IM, AF). Casts obtained from polyether impressions were also scanned using an industrial blue light scanner to construct 3D reference models. Intraoral scanning was performed using CEREC Omnicam (CO) and Trios 3 (TR). Surface matching software (Atos Professional) enabled to determine the mean deviations (mean distances) from the reference casts. Statistically significant discrepancies were calculated using the Wilcoxon signed-rank test. The mean distance for trueness ranged from 0.005 mm (TR) to 0.023 mm (IM) for the full arch, from 0.001 mm (CO) to 0.068 mm (IM) for the anterior segment, and from 0.019 mm (AF) to 0.042 mm (IM) for the posterior segment. Comparing the anterior vs. the posterior segment, significantly less deviations were observed for anterior with CO (p < 0.001) and TR (p < 0.001). Full-arch comparisons revealed significant differences between AF vs. IM (p = 0.014), IM vs. CO (p = 0.002), and IM vs. TR (p = 0.001). Full-arch trueness was comparable when using Affinis and the two intraoral scanners CEREC Omnicam and Trios 3. The digital impression devices yielded higher local deviations within the complete arch. Digital impressions of the complete arch are a suitable and reliable alternative to conventional impressions. However, they should be used with caution in the posterior region.Trial registration: Registration number at the German Clinical Trial Register (04.02.2022): DRKS00027988 (https://trialsearch.who.int/).