Kamiar Aminian

Prof. Kamiar Aminian

Ecole polytechnique federale de Lausanne (EPFL)
orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2002 in Journal of Biomechanics
Verified
Journal Article
Closed access
Kamiar AminianKamiar Aminian
Kamiar Aminian
Bijan NajafiBijan Najafi
Bijan Najafi
CBC. Büla
C. Büla
PLP.-F. Leyvraz
P.-F. Leyvraz
PRPh. Robert
Ph. Robert

11 June 2003 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Bijan NajafiBijan Najafi
Bijan Najafi
Kamiar AminianKamiar Aminian
Kamiar Aminian
APA. Paraschiv-Ionescu
A. Paraschiv-Ionescu
FLF. Loew
F. Loew
CBC.J. Bula
C.J. Bula
PRP. Robert
P. Robert
A new method of physical activity monitoring is presented, which is able to detect body postures (sifting, standing, and lying) and periods of walking in elderly persons using only one kinematic sensor attached to the chest. The wavelet transform, in conjunction with a simple kinematics model, was used to detect different postural transitions (PTs) and walking periods during daily physical activity. To evaluate the system, three studies were performed. The method was first tested on 11 community-dwelling elderly subjects in a gait laboratory where an optical motion system (Vicon) was used as a reference system. In the second study, the system was tested for classifying PTs (i.e., lying-to-sitting, sitting-to-lying, and turning the body in bed) in 24 hospitalized elderly persons. Finally, in a third study monitoring was performed on nine elderly persons for 45-60 min during their daily physical activity. Moreover, the possibility-to-perform long-term monitoring over 12 h has been shown. The first study revealed a close concordance between the ambulatory and reference systems. Overall, subjects performed 349 PTs during this study. Compared with the reference system, the ambulatory system had an overall sensitivity of 99% for detection of the different PTs. Sensitivities and specificities were 93% and 82% in sit-to-stand, and 82% and 94% in stand-to-sit, respectively. In both first and second studies, the ambulatory system also showed a very high accuracy (> 99%) in identifying the 62 transfers or rolling out of bed, as well as 144 different posture changes to the back, ventral, right and left sides. Relatively high sensitivity (> 90%) was obtained for the classification of usual physical activities in the third study in comparison with visual observation. Sensitivities and specificities were, respectively, 90.2% and 93.4% in sitting, 92.2% and 92.1% in "standing + walking," and, finally, 98.4% and 99.7% in lying. Overall detection errors (as percent of range) were 3.9% for "standing + walking," 4.1% for sitting, and 0.3% for lying. Finally, overall symmetric mean average errors were 12% for "standing + walking." 8.2% for sifting, and 1.3% for lying.

19 July 2004 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ASA. Salarian
A. Salarian
HRH. Russmann
H. Russmann
FVF.J.G. Vingerhoets
F.J.G. Vingerhoets
CDC. Dehollain
C. Dehollain
YBY. Blanc
Y. Blanc
Kamiar AminianKamiar Aminian
Kamiar Aminian
An ambulatory gait analysis method using body-attached gyroscopes to estimate spatio-temporal parameters of gait has been proposed and validated against a reference system for normal and pathologic gait. Later, ten Parkinson's disease (PD) patients with subthalamic nucleus deep brain stimulation (STN-DBS) implantation participated in gait measurements using our device. They walked one to three times on a 20-m walkway. Patients did the test twice: once STN-DBS was ON and once 180 min after turning it OFF. A group of ten age-matched normal subjects were also measured as controls. For each gait cycle, spatio-temporal parameters such as stride length (SL), stride velocity (SV), stance (ST), double support (DS), and gait cycle time (GC) were calculated. We found that PD patients had significantly different gait parameters comparing to controls. They had 52% less SV, 60% less SL, and 40% longer GC. Also they had significantly longer ST and DS (11% and 59% more, respectively) than controls. STN-DBS significantly improved gait parameters. During the stim ON period, PD patients had 31% faster SV, 26% longer SL, 6% shorter ST, and 26% shorter DS. GC, however, was not significantly different. Some of the gait parameters had high correlation with Unified Parkinson's Disease Rating Scale (UPDRS) subscores including SL with a significant correlation (r=-0.90) with UPDRS gait subscore. We concluded that our method provides a simple yet effective way of ambulatory gait analysis in PD patients with results confirming those obtained from much more complex and expensive methods used in gait labs.

12 April 2010 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
ASArash Salarian
Arash Salarian
FHFay B. Horak
Fay B. Horak
CZCris Zampieri
Cris Zampieri
Patricia (Patty) Carlson-KuhtaPatricia (Patty) Carlson-Kuhta
Patricia (Patty) Carlson-Kuhta
JNJohn G. Nutt
John G. Nutt
Kamiar AminianKamiar Aminian
Kamiar Aminian
Timed Up and Go (TUG) test is a widely used clinical paradigm to evaluate balance and mobility. Although TUG includes several complex subcomponents, namely: sit-to-stand, gait, 180° turn, and turn-to-sit; the only outcome is the total time to perform the task. We have proposed an instrumented TUG, called iTUG, using portable inertial sensors to improve TUG in several ways: automatic detection and separation of subcomponents, detailed analysis of each one of them and a higher sensitivity than TUG. Twelve subjects in early stages of Parkinson's disease (PD) and 12 age matched control subjects were enrolled. Stopwatch measurements did not show a significant difference between the two groups. The iTUG, however, showed a significant difference in cadence between early PD and control subjects (111.1 ± 6.2 versus 120.4 ± 7.6 step/min, p <; 0.006) as well as in angular velocity of arm-swing (123 ± 32.0 versus 174.0 ± 50.4°/s, p <; 0.005), turning duration (2.18 ± 0.43 versus 1.79 ± 0.27 s, p <; 0.023), and time to perform turn-to-sits (2.96 ± 0.68 versus 2.40 ± 0.33 s, p <; 0.023). By repeating the tests for a second time, the test-retest reliability of iTUG was also evaluated. Among the subcomponents of iTUG, gait, turning, and turn-to-sit were the most reliable and sit-to-stand was the least reliable.

16 May 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FBFabio Bagalà
Fabio Bagalà
CBClemens Becker
Clemens Becker
ACAngelo Cappello
Angelo Cappello
Lorenzo ChiariLorenzo Chiari
Lorenzo Chiari
Kamiar AminianKamiar Aminian
Kamiar Aminian
Jochen KlenkJochen Klenk
Jochen Klenk
Despite extensive preventive efforts, falls continue to be a major source of morbidity and mortality among elderly. Real-time detection of falls and their urgent communication to a telecare center may enable rapid medical assistance, thus increasing the sense of security of the elderly and reducing some of the negative consequences of falls. Many different approaches have been explored to automatically detect a fall using inertial sensors. Although previously published algorithms report high sensitivity (SE) and high specificity (SP), they have usually been tested on simulated falls performed by healthy volunteers. We recently collected acceleration data during a number of real-world falls among a patient population with a high-fall-risk as part of the SensAction-AAL European project. The aim of the present study is to benchmark the performance of thirteen published fall-detection algorithms when they are applied to the database of 29 real-world falls. To the best of our knowledge, this is the first systematic comparison of fall detection algorithms tested on real-world falls. We found that the SP average of the thirteen algorithms, was (mean±std) 83.0%±30.3% (maximum value = 98%). The SE was considerably lower (SE = 57.0%±27.3%, maximum value = 82.8%), much lower than the values obtained on simulated falls. The number of false alarms generated by the algorithms during 1-day monitoring of three representative fallers ranged from 3 to 85. The factors that affect the performance of the published algorithms, when they are applied to the real-world falls, are also discussed. These findings indicate the importance of testing fall-detection algorithms in real-life conditions in order to produce more effective automated alarm systems with higher acceptance. Further, the present results support the idea that a large, shared real-world fall database could, potentially, provide an enhanced understanding of the fall process and the information needed to design and evaluate a high-performance fall detector.

7 August 2002 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Bijan NajafiBijan Najafi
Bijan Najafi
Kamiar AminianKamiar Aminian
Kamiar Aminian
FLF. Loew
F. Loew
YBY. Blanc
Y. Blanc
PRP.A. Robert
P.A. Robert
A new method of evaluating the characteristics of postural transition (PT) and their correlation with falling risk in elderly people is described. The time of sit-to-stand and stand-to-sit transitions and their duration were measured using a miniature gyroscope attached to the chest and a portable recorder placed on the waist. Based on a simple model and the discrete wavelet transform, three parameters related to the PT were measured, namely, the average and standard deviation of transition duration and the occurrence of abnormal successive transitions (number of attempts to have a successful transition). The comparison between two groups of elderly subjects (with high and low fall-risk) showed that the computed parameters were significantly correlated with the falling risk as determined by the record of falls during the previous year, balance and gait disorders (Tinetti score), visual disorders, and cognitive and depressive disorders (p < 0.01). In this study, the wavelet transform has provided a powerful technique for enhancing the pattern of PT, which was mainly concentrated into the frequency range of 0.04-0.68 Hz. The system is especially adapted for long-term ambulatory monitoring of elderly people.