With the improvement of smart grid, utilizing unmanned aerial vehicles (UAV) to detect the operation status of insulators has attracted widespread attention. The insulator defects can lead to serious power loss, damage the service life of power lines, and even result in power outages in serious cases. The small‐scale object, complex background, and limited‐number collected data make insulator defect still a challenging problem. Benefitted by the advances in deep learning, deep learning‐based insulator defects have achieved great progress in recent years. In the paper, the authors present a novel systematic survey of these advances, where further analysis about different processing stages methods is introduced: (i) insulator processing stage methods exploit the specific image pre‐processing algorithm for data augmentation and low‐level vision information extraction; (ii) defect detection stage model can locate and classify diagnosis fault with different task targets, like sequential task strategy and multi‐task strategy. In addition, the authors also review publicly available benchmark and datasets. The future research direction and open problem are discussed to promote the development of the community.
1 September 2008 in Review of Scientific Instruments
Flexure hinges have been used in many engineering areas where high precision and sensitivity are required. Many kinds of flexure profiles were proposed during the past decade. Therefore, a general closed-form solution for flexure hinges of different profiles that incorporates the profile selection and parameter design will be of great benefit to the hinge design. The present work brings circular, right-circular, and elliptical profiles together by proposing a generalized flexure hinge model, which we call elliptical arc flexure hinges (whose maximum eccentric angle ranges from 0 to ) to distinguish from the existing elliptical flexure hinge . Based on the theories of mechanics of materials, all the elements in the compliance matrix for elliptical arc flexure hinges are deduced by introducing the eccentric angle of ellipse as the integral variable. These compliance equations simply boil down to four integrals, thus simplifying the compliance calculation. These equations also apply to elliptical , circular , and right-circular ( and ) hinges. These compliance equations were checked by comparing them with the results of finite element analysis, the existing equations, and experiment results. The comparison results show that these generalized equations are concise and adequate for most design purposes.
Dielectric response measurements are non-invasive and promising diagnostic methods that are being gradually used for assessing the insulation and aging condition of transformer oil-paper insulation system. It is known that moisture content in oil-impregnated insulation has significant effect on its dielectric response phenomena, and whereas at present there is few research about the characteristics of aged cellulose without the impact of water. In this work, a series of experiments are designed and carried out in well-controlled laboratory. Accelerated thermal aging is performed on oil-immersed pressboard samples with different time intervals (0, 120, 250 and 400 h). Then these pressboard samples with different aging states are put into petroleum ether to remove the residual oil inside, and dried in a vacuum oven to remove the petroleum ether and moisture. The degree of polymerization (DP) and scanning electron microscope (SEM) are implemented to characterize the aging status of pressboard samples. Two kinds of dielectric response tests, i.e., the polarization and depolarization currents (PDC) and frequency domain spectroscopy (FDS), are performed on each oil/water-removed pressboard sample in vacuum and new-oil-impregnated ambient, respectively. Samples with different aging states show quite different dielectric response characteristics in both ambients. With the aging status more serious, the pressboard sample exhibits higher values of polarization/depolarization currents and complex capacitances. It is confirmed that, besides the influence of water induced by aging, the deterioration of cellulose itself also causes the increasing of pressboard conductivity, and hence greatly affects the PDC and FDS test results. Dielectric response diagnostic techniques have a potential to reflect the aging information of solid insulation.
Inertia weight is one of the most important parameters of particle swarm optimization (PSO) algorithm. Based on the basic idea of decreasing inertia weight (DIW), two strategies of natural exponential functions were proposed. Four different benchmark functions were used to evaluate the effects of these strategies on the PSO performance. The results of the experiments show that these two new strategies converge faster than linear one during the early stage of the search process. For most continuous optimization problems, these two strategies perform better than the linear one
26 September 2017 in IEEE Transactions on Instrumentation and Measurement
The icing on transmission line conductor usually causes accidents such as conductor galloping, conductor breaking, line tripping, and even network paralyzing, which could bring serious threats to the safe operation of the power system. The conductor icing shape not only has a great influence on the estimate to melting ice time or melting ice current, but also directly affects the mechanical calculation of conductor galloping. Therefore, it is paramount to determine the conductor icing shape. Many available artificial measurements are inaccurate and even ineffective enough in some cases. This paper proposes a novel online technology for measuring icing shape on transmission line conductor based on vision and force sensors. The proposed technique consists of three parts, namely, the online device based on vision and force sensors, the communication network, and the monitoring center. The images of the iced conductor are captured from two cameras, and the processing algorithms are used to extract the average diameters of the iced conductor. The equivalent cross-sectional area is also obtained by the force sensors and a built-in mechanics model. The icing shape description algorithm is proposed to accurately represent the icing shape. We thoroughly analyze the performance of the technology by a series of experiments under artificial icing simulations and natural conditions. The experimental results demonstrate that the proposed method can measure the icing shapes with the overlap ratio of greater than 0.85. In addition, the proposed measuring technology shows satisfactory results on the field tests carried out on operating transmission lines.