Yong Choi

Prof. Yong Choi

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2013 in Medical Physics
Verified
Journal Article
Closed access
PDF file
KHKey Jo Hong
Key Jo Hong
YCYong Choi
Yong Choi
JKJihoon Kang
Jihoon Kang
WHWei Hu
Wei Hu
HLHyun Keong Lim
Hyun Keong Lim
HPHyun‐Wook Park
Hyun‐Wook Park

26 January 2016 in Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
JJJin Ho Jung
Jin Ho Jung
YCYong Choi
Yong Choi
KIKi Chun Im
Ki Chun Im

8 October 2010 in Medical Physics
Verified
Journal Article
Closed access
PDF file
JKJihoon Kang
Jihoon Kang
YCYong Choi
Yong Choi
KHKey Jo Hong
Key Jo Hong
JJJin Ho Jung
Jin Ho Jung
WHWei Hu
Wei Hu
BKByung‐Tae Kim
Byung‐Tae Kim

1 May 2015 in Medical Physics
Verified
Journal Article
Closed access
PDF file
JJJin Ho Jung
Jin Ho Jung
YCYong Choi
Yong Choi
JJJiwoong Jung
Jiwoong Jung
SKSangsu Kim
Sangsu Kim
HLHyun Keong Lim
Hyun Keong Lim
JKJong Guk Kim
Jong Guk Kim

6 March 2017 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
HCHyeok-Jun Choe
Hyeok-Jun Choe
YCYong Choi
Yong Choi
WHWei Hu
Wei Hu
JYJianhua Yan
Jianhua Yan
JJJin Ho Jung
Jin Ho Jung
There has been great interest in developing a time-of-flight (TOF) PET to improve the signal-to-noise ratio of PET image relative to that of non-TOF PET. Silicon photomultiplier (SiPM) arrays have attracted attention for use as a fast TOF PET photosensor. Since numerous SiPM arrays are needed to construct a modern human PET, a multiplexing method providing both good timing performance and high channel reduction capability is required to develop a SiPM-based TOF PET. The purpose of this study was to develop a capacitive multiplexing circuit for the SiPM-based TOF PET. The proposed multiplexing circuit was evaluated by measuring the coincidence resolving time (CRT) and the energy resolution as a function of the overvoltage using three different capacitor values of 15, 30, and 51 pF. A flood histogram was also obtained and quantitatively assessed. Experiments were performed using a 4 × 4 array of 3 × 3 mm 2 SiPMs. Regarding the capacitor values, the multiplexing circuit using a smaller capacitor value showed the best timing performance. On the other hand, the energy resolution and flood histogram quality of the multiplexing circuit deteriorated as the capacitor value became smaller. The proposed circuit was able to achieve a CRT of 260 ± 4 ps FWHM and an energy resolution of 17.1 % with a pair of 2 × 2 × 20 mm 3 LYSO crystals using a capacitor value of 30 pF at an overvoltage of 3.0 V. It was also possible to clearly resolve a 6 × 6 array of LYSO crystals in the flood histogram using the multiplexing circuit. The experiment results indicate that the proposed capacitive multiplexing circuit is useful to obtain an excellent timing performance and a crystal-resolving capability in the flood histogram with a minimal degradation of the energy resolution, as well as to reduce the number of the readout channels of the SiPM-based TOF PET detector.

1 August 2011 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
JKJihoon Kang
Jihoon Kang
YCYong Choi
Yong Choi
KHKey Jo Hong
Key Jo Hong
WHWei Hu
Wei Hu
JJJin Ho Jung
Jin Ho Jung
BKByung-Tae Kim
Byung-Tae Kim