Xiaowei Fang

Mr. Xiaowei Fang

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
XFXiaowei Fang
Xiaowei Fang
SYShuiping Yang
Shuiping Yang
KCKonstantin Chingin
Konstantin Chingin
LZLiang Zhu
Liang Zhu
XZXinglei Zhang
Xinglei Zhang
ZZZhanfeng Zhao
Zhanfeng Zhao
Exposure to malachite green (MG) may pose great health risks to humans; thus, it is of prime importance to develop fast and robust methods to quantitatively screen the presence of malachite green in water. Herein the application of extractive electrospray ionization mass spectrometry (EESI-MS) has been extended to the trace detection of MG within lake water and aquiculture water, due to the intensive use of MG as a biocide in fisheries. This method has the advantage of obviating offline liquid-liquid extraction or tedious matrix separation prior to the measurement of malachite green in native aqueous medium. The experimental results indicate that the extrapolated detection limit for MG was ~3.8 μg·L−1 (S/N = 3) in lake water samples and ~0.5 μg·L−1 in ultrapure water under optimized experimental conditions. The signal intensity of MG showed good linearity over the concentration range of 10–1000 μg·L−1. Measurement of practical water samples fortified with MG at 0.01, 0.1 and 1.0 mg·L−1 gave a good validation of the established calibration curve. The average recoveries and relative standard deviation (RSD) of malachite green in lake water and Carassius carassius fish farm effluent water were 115% (6.64% RSD), 85.4% (9.17% RSD) and 96.0% (7.44% RSD), respectively. Overall, the established EESI-MS/MS method has been demonstrated suitable for sensitive and rapid (<2 min per sample) quantitative detection of malachite green in various aqueous media, indicating its potential for online real-time monitoring of real life samples.

21 December 2018 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
SSSusu Shen
Susu Shen
HZHua Zhang
Hua Zhang
KHKeke Huang
Keke Huang
HCHuanwen Chen
Huanwen Chen
WSWenxin Shen
Wenxin Shen
XFXiaowei Fang
Xiaowei Fang
The quality of rice, a widely served staple food in the world, is usually assessed based on the levels of free fatty acids (FFAs). Therefore, a method for the rapid detection and quantification of FFAs in rice grains or even a single rice grain would make rice quality evaluation easier. In this study, we developed a single grain electrospray ionization (SG-ESI) source where a single grain of rice was placed in a small chamber in-line with an electrospray ionization source for mass spectrometric analysis. The characteristic fingerprint of every single rice grain was rapidly recorded by the single grain mass spectrometry without tedious sample pre-treatment (such as off-line extraction, centrifugation and/or separation). Semi-quantitative determination of typical FFAs and pesticides in the single rice grain samples was successfully achieved, providing the limits of detection (LODs) of 0.11–1.30 ng g−1 and the recovery rates of 77.68–91.52% (RSDs ≤ 9.54%). The rice grains of different cultivation areas and/or storage times were differentiated by the full scan mass spectral data processed using multivariate statistical analysis. The experimental results demonstrate that the established single grain mass spectrometry is a useful tool for the direct analysis of rice grains with minimal sample preparation, low sample consumption, high sensitivity and high throughput.

1 December 2021 in Zhonghua Wei Zhong Bing Ji Jiu Yi Xue
Verified
Journal Article
Closed access
XMXianlin Meng
Xianlin Meng
LZLei Zhang
Lei Zhang
XFXiaoqin Fan
Xiaoqin Fan
XFXiaowei Fang
Xiaowei Fang
APAijun Pan
Aijun Pan
To evaluate the diagnostic value of metagenomics next-generation sequencing (mNGS) in detecting pathogens in bronchoalveolar lavage fluid (BALF) for pulmonary infection in solid organ transplant patients in intensive care unit (ICU). A retrospective study was conducted, the BALF samples from 46 patients with post organ transplant pneumonia/suspected pneumonia admitted to the Department of Critical Care Medicine of the First Affiliated Hospital of University of Science and Technology of China from August 2018 to August 2021 were collected, all tested by simultaneous mNGS and conventional comprehensive microbial test (CMT), and the results of CMT were used as the reference standard to compare the differences in the diagnostic value of mNGS and CMT for pulmonary infections in solid organ transplant patients, and to analyze the diagnostic value of mNGS for mixed infections. (1) Pneumonia pathogens: a total of 31 pathogens were detected in 35 patients, including bacteria (16 species), fungi (9 species) and viruses (6 species). Among them, 25 pathogens were detected by mNGS and CMT, and only 19 pathogens were detected by mNGS. Among the microorganisms isolated by mNGS method, the detection rates of Pseudomonas aeruginosa, Acinetobacter baumannii and Klebsiella pneumoniae were higher [51.4% (18/35), 42.9% (15/35), 31.4% (11/35), respectively]; Candida albicans, Aspergillus and Pneumocystis carinii were the most commonly detected fungi [31.4% (11/35), 22.9% (8/35), 22.9% (8/35), respectively]; 20 patients were positive for the virus, and the most commonly detected viruses were cytomegalovirus, herpesvirus and EB virus [28.6% (10/35), 20.0% (7/35), 17.1% (6/35), respectively]. In addition, one case of Brucella was detected by mNGS. (2) Diagnostic efficiency: as far as bacterial detection is concerned, 20 cases of negative results were obtained by CMT detection of 35 samples included in the study, and a total of 10 cases of positive results were obtained by mNGS detection of negative samples; the percentage of mNGS positive samples was significantly higher than that of CMT positive samples [odds ratio (OR) = 5.5, 95% confidence interval (95%CI) = 1.2-24.8, P = 0.02]. When compared with CMT, the sensitivity and specificity of mNGS were 93.3% and 50.0%, and the positive predictive value (PPV) and negative predictive value (NPV) were 58.3%, 91.1%. As far as fungal detection was concerned, there was no significant difference in the percentage of positive samples between the two methods (OR = 1.5, 95%CI = 0.5-4.2, P = 0.60); the sensitivity and specificity of mNGS were 72.2% and 64.7%, and the PPV and NPV were 68.4%, 68.8%; CMT test of the 35 included samples produced 17 negative results, and mNGS test of the negative samples produced 6 positive results. A total of 20 patients tested positive for the virus by mNGS. In addition, 23 patients (65.7%) were diagnosed with pulmonary mixed infection. The use of mNGS to detect pathogens in BALF can improve the sensitivity and specificity of bacterial identification of pulmonary infection in critically ill organ transplant patients, and mNGS has obvious advantages in detecting virus and identifying mixed infections.

23 June 2010 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
NLNuo Liu
Nuo Liu
YLYan-Rong Li
Yan-Rong Li
NLNing Lu
Ning Lu
YYYongxin Yao
Yongxin Yao
XFXiaowei Fang
Xiaowei Fang
KHKai-Ming Ho
Kai-Ming Ho
We report a first-principles study of Ge/Si and Si/Ge core/shell nanowires (NWs) along the [1 1 2] direction with a diameter of ∼20 Å using density-functional theory. Our results show that for both NW structures the band gaps are indirect and are significantly larger than the gaps of the bulk crystalline Si and Ge. The quantum well confinement effect in these NWs is found to be modified by a type II lineup of band structures. Moreover, the carriers on the conduction band minimum are strongly localized in the Si region while the carriers on the valence band maximum are located mainly in the Ge region. The charge separation and localization characters make the NWs good candidates for nanochannels in field effect devices, solar cells with higher efficiency and high mobility heterostructures due to the spatial separation of one-dimensional electron gas and one-dimensional hole gas.

11 August 2016 in Preprints.org
Verified
Preprint
Open access
PDF file
XFXiaowei Fang
Xiaowei Fang
SYShuiping Yang
Shuiping Yang
KCKonstantin Chingin
Konstantin Chingin
LZLiang Zhu
Liang Zhu
XZXinglei Zhang
Xinglei Zhang
ZZZhanfeng Zhao
Zhanfeng Zhao
Exposure to malachite green (MG) may pose great health risks to humans, thus it is of prime importance to develop fast and robust methods to quantitatively screen the presence malachite green in environment. Herein application of extractive electrospray ionization mass spectrometry (EESI-MS) has been extended to the trace detection of MG within lake water and aquiculture water, due to the intensive use of MG as biocide in fisheries. This method has the advantage of obviating offline liquid-liquid extraction or tedious matrix separation prior to the measurement of malachite green in native aqueous medium. The experimental results indicate that the extrapolated detection limit for MG was ~3.8 ug L-1 (S/N=3) in lake water samples and ~ 0.5 ug L-1 in ultrapure water under optimized experimental conditions. The signal intensity of MG showed good linearity over the concentration range of 10–5000 ug L-1. Measurement of practical water samples fortified with MG at 0.01 and 0.1 mg L-1 gave a good validation of the established calibration curve. The average recoveries of malachite green in lake water and Carassius carassius fish farm effluent water were 114.9% (6.6% RSD) and 85.4% (9.2% RSD), respectively. Overall, the established EESI-MS/MS method has been demonstrated suitable for sensitive and rapid (<2 min per sample) quantitative detection of malachite green in various aqueous media, indicating its potential for online real-time monitoring of real life samples.

28 October 2025 in Molecules
Verified
Journal Article
Open access
PDF file
XZXinrui Zhang
Xinrui Zhang
YQYuqi Qiu
Yuqi Qiu
HXHuiyu Xing
Huiyu Xing
FYFeixiang Yang
Feixiang Yang
PZPeng Zeng
Peng Zeng
XFXiaowei Fang
Xiaowei Fang
Selenium, a crucial trace element for human health, plays a vital role in maintaining well-being. Its insufficiency can cause various diseases, highlighting the need for adequate selenium intake in daily diets. Honey, containing diverse selenium compounds, serves as a beneficial selenium supplement. By leveraging the distinctive physicochemical properties of honey, we employed reactive extractive electrospray ionization mass spectrometry (EESI-MS) to rapidly analyze the presence of both organic selenium (selenomethionine) and inorganic selenium (sodium selenite) in diluted honey samples. We successfully identified selenomethionine (SeMet) and sodium selenite. Calibration curves constructed for SeMet and sodium selenite demonstrated excellent linear relationships within the concentration range of 0.5 to 50 µg/L. The limits of detection (LOD) for SeMet and sodium selenite were determined to be 2.94 µg/kg and 5.18 µg/kg, respectively, while the limits of quantification (LOQ) were 9.52 µg/kg and 17.4 µg/kg, respectively. Furthermore, spiked recoveries ranged from 90.6% to 105%. The average analysis time is 2 min. This study presents a precise, rapid, and convenient method for selenium determination in diluted honey. Given the limited sample size in this preliminary study, future research with larger cohorts is required to validate our findings.