Severe tricuspid commitment is no longer understood as merely a marker of disease but is now widely thought of as a significant contributor to cardiac morbidity and mortality. However, isolated tricuspid valve surgery remains rare and to this day continues to be associated with the highest surgical risk among all valve procedures and high operative mortality rates, especially in reoperations. Therefore, the development of tricuspid transcatheter procedures is as necessary as it was for the other valves a couple of years ago. Recently, multiple percutaneous therapies have been developed for the management of severe tricuspid disease, initially only repair and more recently replacement, thus creating a new branch for the management of patients who have already undergone surgery and who present with dysfunctional bioprostheses. The purpose of this review and report is to demonstrate current and possible future challenges, and to show that the valve-in-valve procedure of the tricuspid valve is feasible and safe, and now can be performed in all its range, in the smallest to the largest sizes of presentation, without incurring the untoward risks of conventional surgery.
1 January 2017 in Arquivos Brasileiros de Cardiologia
Atrial fibrillation (AF) is a cardiac arrhythmia with high risk for thromboembolic events, specially stroke. To assess the safety of left atrial appendage closure (LAAC) with the Amplatzer Cardiac Plug for the prevention of thromboembolic events in patients with nonvalvular AF. This study included 15 patients with nonvalvular AF referred for LAAC, 6 older than 75 years (mean age, 69.4 ± 9.3 years; 60% of the male sex). The mean CHADS2 score was 3.4 ± 0.1, and mean CHA2DS2VASc , 4.8 ± 1.8, evidencing a high risk for thromboembolic events. All patients had a HAS-BLED score > 3 (mean, 4.5 ± 1.2) with a high risk for major bleeding within 1 year. The device was successfully implanted in all patients, with correct positioning in the first attempt in most of them (n = 11; 73.3%). There was no periprocedural complication, such as device migration, pericardial tamponade, vascular complications and major bleeding. All patients had an uneventful in-hospital course, being discharged in 2 days. The echocardiographic assessments at 6 and 12 months showed neither device migration, nor thrombus formation, nor peridevice leak. On clinical assessment at 12 months, no patient had thromboembolic events or bleeding related to the device or risk factors. In this small series, LAAC with Amplatzer Cardiac Plug proved to be safe, with high procedural success rate and favorable outcome at the 12-month follow-up. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0).