Duchenne muscular dystrophy (DMD) cardiomyopathy (DCM) is characterized by a hypokinetic, dilated phenotype progressively increasing with age. Regular cardiac care is crucial in DMD care. Early recognition and prophylactic use of angiotensin converting enzyme inhibitors (ACEi) are the main stay therapeutic strategy to delay incidence of DMD-DCM. Pharmacological treatment to improve symptoms and left ventricle (LV) systolic function, have been widely implemented in the past years. Because of lack of DMD specific drugs, actual indications for established DCM include current treatment for heart failure (HF). This review focuses on current HF strategies to identify, characterize, and treat DMD-DCM.
Since the spread of COVID-19, pediatric patients were initially considered less affected by SARS-COV-2, but current literature reported subsets of children with multisystem inflammatory syndrome (MIS-C). This study aims to describe the cardiac manifestation of SARS-COV-2 infection in a large cohort of children admitted to two Italian pediatric referral centers. Between March 2020 and March 2021, we performed a cardiac evaluation in 294 children (mean age 9 ± 5.9 years, male 60%) with active or previous SARS-COV-2 infection. Twenty-six showed ECG abnormalities: 63 repolarization anomalies, 13 Long QTc, five premature ventricular beats, two non-sustained ventricular tachycardia, and one atrial fibrillation. In total, 146 patients underwent cardiac biomarkers: NT-proBNP was elevated in 57, troponin in 34. An echocardiogram was performed in 98, showing 54 cardiac anomalies: 27 left-ventricular dysfunction, 42 pericarditis, 16 coronaritis. MIS-C was documented in 46 patients (mean age 9 ± 4.8 years, male 61%) with cardiac manifestations in 97.8%: 27 ventricular dysfunctions, 32 pericarditis, 15 coronaritis, 3 arrhythmias. All patients recovered, and during follow-up, no cardiac anomalies were recorded. Our experience showed that cardiac involvement is not rare in children with SARS-COV-2, and occurred in almost all patients with MIS-C. However, patients’ recovery is satisfactory and no additional events were reported during FU.
MIS-C is a multisystem inflammatory syndrome that is characterized by multi-organ failure and cardiac involvement. The aim of this study was to describe the long-term cardiovascular outcome in a cohort of MIS-C pediatric patients, who were admitted to two Italian Pediatric Referral Centers. Sixty-seven patients (mean age 8.7 ± 4.7 years, male 60%) were included; 65 (97%) of them showed cardiac involvement. All of the patients completed one month of the follow-up, and 47% completed 1 year of it. ECG abnormalities were present in 65% of them, arrhythmias were present in 9% of them during an acute phase and it disappeared at the point of discharge or later. Pericarditis were detected in 66% of them and disappeared after 6 months. Coronaritis was observed in 35% of the children during an acute phase, and there were no more instances at the 1-year point. An LV dysfunction was present in 65% of the patients at the beginning of the study, with them having a full recovery at the point of discharge and thereafter. Elevated values of the NTproBNP and hsTp were initially detected, which progressively decreased and normalized at the points of discharge and FU. The CMR at the point of FU, there was a presence of long-term myocardial scars in 50% of the patients that were tested. No deaths that were caused by MIS-C during the FU were recorded. Cardiac involvement in MIS-C patients is almost the rule, but the patients’ clinical course was satisfactory, and no additional events or sequelae were observed apart from there being long-term myocardial scars in 50% of the patients that underwent CMR.
The extracardiac conduit-Fontan (ECC) has become the preferred technique for univentricular heart palliation, but there are currently no data on the incidence of long-term arrhythmias. This study investigated the incidence of arrhythmias and relation to single ventricle morphology in the long-term follow-up (FU) in ECC. All patients with ECC performed in our Centre between 1987 and 2017 were included (minimum FU 5 years). Of 353 consecutive patients, 303 [57.8% males, aging 8–50 (median 20) years at last FU] were considered and divided into two groups depending on left (194 in Group 1) or right (109 in Group 2) ventricular morphology. Eighty-five (28%) experienced ≥1 arrhythmic complications, with early and late arrhythmias in 17 (5.6%) and 73 (24.1%) patients, respectively. Notably, late bradyarrhythmias occurred after 6 years in 21 (11%) patients in Group 1, and in 15 (13.8%) in Group 2 [P = 0.48]. Late tachyarrhythmias occurred in 55 (18.2%) patients after 12 years: 33 (17%) in Group 1 and 22 (20.2%) patients in Group 2 [P= 0.5]. Ventricular tachycardias (VT) were documented after 12.5 years in 14 (7.2%) patients of Group 1 and 15 (13.8%) of Group 2 [P = 0.06] with a higher incidence in Group 2 during the FU [P = 0.005]. Extracardiac conduit is related to a significant arrhythmic risk in the long-term FU, higher than previously reported. Bradyarrhythmias occur earlier but are less frequent than tachyarrhythmias. Interestingly, patients with systemic right ventricle have a significantly higher incidence of VT, especially in a very long FU.
Whilst there has been significant public health benefits associated with global use of COVID-19 spike protein vaccines, potential serious adverse events following immunization have been reported. Acute myocarditis is a rare complication of COVID19 vaccines and often it is self-limiting. We describe two cases experiencing recurrent myocarditis following mRNA COVID-19 vaccine despite a prior episode with full clinical recovery. Between September 2021-September 2022 we observed two male adolescents with recurrent myocarditis related to mRNA-based-COVID19 vaccine. During the first episode both patients presented with fever and chest pain few days after their second dose of BNT162b2 mRNA Covid-19 Vaccine (Comirnaty®). The blood exams showed increased cardiac enzymes. In addition, complete viral panel was run, showing HHV7 positivity in a single case. The left ventricular ejection fraction (LVEF) was normal at echocardiogram but cardiac magnetic resonance scanning (CMR) was consistent with myocarditis. They were treated with supportive treatment with full recovery. The 6 months follow-up demonstrated good clinical conditions with normal cardiological findings. The CMR showed persistent lesions in left ventricle ‘s wall with LGE. After some months the patients presented at emergency department with fever and chest pain and increased cardiac enzymes. No decreased LVEF was observed. The CMR showed new focal areas of edema in the first case report and stable lesions in the second one. They reached full recovery with normalization of cardiac enzymes after few days. These case reports outline the need of strict follow-up in patients with CMR consistent with myocarditis after mRNA-based-COVID19 vaccine. More efforts are necessary to depict the underlying mechanisms of myocarditis after SARS-CoV2 vaccination to understand the risk of relapsing and the long-term sequelae.
Background: Pediatric patients with cardiomyopathies are at risk of malignant arrhythmias and sudden cardiac death (SCD). An ICD may prevent SCD. The aim of this study was to evaluate ICD implantation outcomes, and to compare transvenous and subcutaneous ICDs (S-ICDs) implanted in pediatric patients with cardiomyopathies. Methods: The study is single center and retrospective, and includes pediatric patients with cardiomyopathies who required ICD implantation (2010–2021). Outcomes were recorded for appropriate/inappropriate ICD therapy and surgical complications. Transvenous ICD and S-ICD were compared. Data are presented as median values (25th–75th centiles). Results: Forty-four patients with cardiomyopathies (hypertrophic 39%, arrhythmogenic 32%, dilated 27%, and restrictive 2%) underwent transvenous (52%) and S-ICD (48%) implantation at 14 (12–17) years of age, mostly for primary prevention (73%). The follow-up period was 29 (14–60) months. Appropriate ICD therapies were delivered in 25% of patients, without defibrillation failures. Lower age at implantation and secondary prevention were significant risk factors for malignant ventricular arrhythmias that required appropriate ICD therapies. ICD-related complications were surgical complications (18%) and inappropriate shocks (7%). No significant differences in outcomes were recorded, either when comparing transvenous and S-ICD or comparing the different cardiomyopathies. Conclusions: In pediatric patients with cardiomyopathy, ICD therapy is effective, with a low rate of inappropriate shocks. Neither ICD type (transvenous and S-ICDs) nor the cardiomyopathies subgroup revealed divergent outcomes.