Different additive manufacturing technologies have proven effective and useful in remote medicine and emergency or disaster situations. The coronavirus disease 2019 (COVID-19) disease, caused by the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) virus, has had a huge impact on our society, including in relation to the continuous supply of personal protective equipment (PPE). The aim of the study is to give a detailed overview of 3D-printed PPE devices and provide practical information regarding the manufacturing and further design process, as well as describing the potential risks of using them. Open-source models of a half-face mask, safety goggles, and a face-protecting shield are evaluated, considering production time, material usage, and cost. Estimations have been performed with fused filament fabrication (FFF) and selective laser sintering (SLS) technology, highlighting the material characteristics of polylactic acid (PLA), polyamide, and a two-compound silicone. Spectrophotometry measurements of transparent PMMA samples were performed to determine their functionality as goggles or face mask parts. All the tests were carried out before and after the tetra-acetyl-ethylene-diamine (TAED)-based disinfection process. The results show that the disinfection has no significant effect on the mechanical and structural stability of the used polymers; therefore, 3D-printed PPE is reusable. For each device, recommendations and possible means of development are explained. The files of the modified models are provided. SLS and FFF additive manufacturing technology can be useful tools in PPE development and small-series production, but open-source models must be used with special care.
Direct laryngoscopy remains the gold standard for endotracheal intubation and is preferred by experienced operators. However, an increasing number of reports currently support videolaryngoscopy, particularly for novice users. The widespread use of videolaryngoscopy may be limited due to financial limitations, especially in low-income countries. Therefore, affordable single-use scopes are now becoming increasingly popular. We sought to compare these new scopes with direct laryngoscopes and the previously tested videolaryngoscopes in mannequins by novices. Fifty medical students were recruited to serve as novice users. Following brief, standardized training, students were asked to execute endotracheal intubation with each of the devices, including the Airtraq®, a custom-made videolaryngoscope, the King Vision®, the Macintosh laryngoscope and the VividTrac®, on an airway trainer (Laerdal Airway Management Trainer®) in normal and difficult airway scenarios. We evaluated the time to and the proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction. We observed no differences in esophageal intubation. However, intubation-related times, the view of the glottis and operator satisfaction were significantly better throughout the study with the commercial videolaryngoscopes. In comparison, the custom-made videolaryngoscope performance proved to be similar to that of the Macintosh laryngoscope. The VividTrac® performance was similar (P > 0.05) or significantly better than that of the King Vision® in both scenarios. Based upon our results, the Airtraq®, King Vision® and VividTrac® were superior to the Macintosh laryngscope in both normal and difficult airway scencarios for novice users. In particular, our study is the first to report that the VividTrac® shows promise for further clinical evaluation.
3D printing is an emerging and disruptive technology, supporting the field of medicine over the past decades. In the recent years, the use of additive manufacturing (AM) has had a strong impact on everyday dental applications. Despite remarkable previous results from interdisciplinary research teams, there is no evidence or recommendation about the proper fabrication of handheld medical devices using desktop 3D printers. The aim of this study was to critically examine and compare the mechanical behavior of materials printed with FFF (fused filament fabrication) and CFR (continuous fiber reinforcement) additive manufacturing technologies, and to create and evaluate a massive and practically usable right upper molar forceps. Flexural and torsion fatigue tests, as well as Shore D measurements, were performed. The tensile strength was also measured in the case of the composite material. The flexural tests revealed the measured force values to have a linear correlation with the bending between the 10 mm (17.06 N at 5000th cycle) and 30 mm (37.99 N at 5000th cycle) deflection range. The findings were supported by scanning electron microscopy (SEM) images. Based on the results of the mechanical and structural tests, a dental forceps was designed, 3D printed using CFR technology, and validated by five dentists using a Likert scale. In addition, the vertical force of extraction was measured using a unique molar tooth model, where the reference test was carried out using a standard metal right upper molar forceps. Surprisingly, the tests revealed there to be no significant differences between the standard (84.80 N ± 16.96 N) and 3D-printed devices (70.30 N ± 4.41 N) in terms of extraction force in the tested range. The results also highlighted that desktop CFR technology is potentially suitable for the production of handheld medical devices that have to withstand high forces and perform load-bearing functions.
Introduction: A major complication of sepsis is the development of acute kidney injury (AKI). Recently, it was shown that intracellular actin released from damaged tissues appears in the urine of patients with multiple organ dysfunction syndrome. Our aims were to measure urinary actin (u-actin) concentrations of septic and control patients and to test if u-actin levels could predict AKI and mortality. Methods: Blood and urine samples were collected from septic and sepsis-related AKI patients at three time points (T1-3): T1: within 24 hours after admission; T2: second day morning; T3: third day morning of follow-up. Patients with malignancies needing palliative care, end-stage renal disease or kidney transplantation were excluded. Serum and u-actin levels were determined by quantitative Western blot. Patients were categorized by the Sepsis-3 and KDIGO AKI classifications. Results: In our study, 17 septic, 43 sepsis-induced AKI and 24 control patients were enrolled. U-actin levels were higher in septic patients compared with controls during follow-up (p<0.001). At T1, the septic and sepsis-related AKI groups also showed differences (p<0.001), yet this increase was not statistically significant at T2 and T3. We also detected significantly elevated u-actin concentrations in AKI-2 and AKI-3 septic patients compared with AKI-1 septic patients (p<0.05) at T1 and T3, along with a significant increase in AKI-2 septic patients compared with AKI-1 septic patients at T2 (p<0.01). This tendency remained the same when referring u-actin to urine creatinine. Parameters of first-day septic patient samples could discriminate AKI from non-AKI state (AUC ROC, p<0.001): u-actin: 0.876; se-creatinine: 0.875. Derived cut-off value for u-actin was 2.63 μg/L (sensitivity: 86.0%, specificity: 82.4%). Conclusion: U-actin may be a complementary diagnostic biomarker to se-creatinine in sepsis-related AKI while higher u-actin levels also seem to reflect the severity of AKI. Further investigations may elucidate the importance of u-actin release in sepsis-related AKI.