Nanoparticles (NPs) have been used to produce a wide range of products that have applications in imaging and drug delivery in medicine. Due to their chemical stability, well-controlled sizes and surface charges, polystyrene (PS) NPs have been developed as biosensors and drug delivery carriers. However, the possible adverse biological effects and underlying mechanisms are still unclear. Recently, autophagy has been implicated in the regulation of cell death. In this study, we evaluated a library of PS NPs with different surface charges. We found that NH2-labeled polystyrene (NH2-PS) nanospheres were highly toxic with enhanced uptake in macrophage (RAW 264.7) and lung epithelial (BEAS-2B) cells. Furthermore, NH2-PS could induce autophagic cell death. NH2-PS increased autophagic flux due to reactive oxygen species (ROS) generation and endoplasmic reticulum (ER) stress caused by misfolded protein aggregation. The inhibition of ER stress decreased cytotoxicity and autophagy in the NH2-PS-treated cells. In addition, the Akt/mTOR and AMPK signaling pathways were involved in the regulation of NH2-PS-triggered autophagic cell death. These results suggest an important role of autophagy in cationic NP-induced cell death and provide mechanistic insights into the inhibition of the toxicity and safe material design.
1 September 2001 in Journal of Pharmaceutical Sciences
The permeability barrier of skin resides in the stratum corneum, and its properties are mediated by a series of lipid multilayers, enriched in ceramides, cholesterol, and free fatty acids, segregated within the stratum corneum (SC) interstices. SC lipid content is usually determined by gravimetric methods in conjunction with high performance thin layer chromatography, but these methods are time‒consuming and involve hazardous solvents. The objective of the present study was to develop a method of measuring SC lipid content by Fourier transform infrared spectrometry (FTIR) that is fast and requires no solvents. The IR spectra of isolated porcine SC sheets were recorded using a FTIR spectrometer. SC lipid content was determined by gravimetric methods using chloroform–methanol extraction. The peak area of both the CH2 symmetric (2850 cm−1) and asymmetric (2920 cm−1) stretching bands in the IR spectra of progressively solvent‒extracted porcine SC sheets decreased with increasing amount of SC lipids removed. When spectral analysis was performed by curve‒fitting using GRAMS/32 software between 3000 to 2800 cm−1, peak area ratios of CH2 to CH3 asymmetric stretching bands in the IR spectra of 46 isolated porcine SC samples were correlated to SC lipid content (R2=0.90), with the standard error of measurement of 1.91%. The study demonstrated the feasibility of using FTIR technique to rapidly and accurately measure SC lipid content.
1 July 2003 in Archives of Dermatological Research