María Araceli Gago-Arias

Dr. María Araceli Gago-Arias

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DRDusan Racordon
Dusan Racordon
AVAndrés Valdivia
Andrés Valdivia
GMGabriel Mingo
Gabriel Mingo
RERafaela Erices
Rafaela Erices
RARaúl Aravena
Raúl Aravena
GOGareth Owen
Gareth Owen
Vasculogenic mimicry (VM) describes a process by which cancer cells establish an alternative perfusion pathway in an endothelial cell-free manner. Despite its strong correlation with reduced patient survival, controversy still surrounds the existence of an in vitro model of VM. Furthermore, many studies that claim to demonstrate VM fail to provide solid evidence of true hollow channels, raising concerns as to whether actual VM is actually being examined. Herein, we provide a standardized in vitro assay that recreates the formation of functional hollow channels using ovarian cancer cell lines, cancer spheres and primary cultures derived from ovarian cancer ascites. X-ray microtomography 3D-reconstruction, fluorescence confocal microscopy and dye microinjection conclusively confirm the existence of functional glycoprotein-rich lined tubular structures in vitro and demonstrate that many of structures reported in the literature may not represent VM. This assay may be useful to design and test future VM-blocking anticancer therapies.

20 March 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MGMaría Araceli Gago-Arias
María Araceli Gago-Arias
LBL Brualla-González
L Brualla-González
DGD M González-Castaño
D M González-Castaño
FGF Gómez
F Gómez
MGM Sánchez García
M Sánchez García
JPJuan Pardo-Montero
Juan Pardo-Montero
This work is devoted to studying the influence of chamber response functions on the standard IMRT verification for the different detector technologies available on commercial devices. We have tested three of the most used 2D detector arrays for radiotherapy dosimetry verification, based on air-ionization chambers and diode detectors. The response function has been carefully simulated using the Monte Carlo method and measured through slit and pinhole collimators. Although the response function of air-ionization detectors is considerably different with respect to that of standard diodes, the impact on a verification based in the gamma function with tolerances 3 mm and 3% is quite limited. The results show that the standard air-ionization detector arrays perform in a similar way whenever the tolerances for the gamma function are not lowered below 1.5 mm and 1.5%. Additionally, the sensitivity of these devices to fluence perturbations was measured by intentionally modifying some leaf positions in the multileaf collimator. The wider response function of air-ionization chamber arrays made them slightly more sensitive to random fluence perturbations, although silicon diode arrays are more accurate to describe the dose distribution in a point by point basis.

20 March 2012 in Medical Physics
Verified
Journal Article
Closed access
MGMaría Araceli Gago-Arias
María Araceli Gago-Arias
RRRuth Rodríguez‐Romero
Ruth Rodríguez‐Romero
PSPatricia Sánchez‐Rubio
Patricia Sánchez‐Rubio
DGDiego Miguel González‐Castaño
Diego Miguel González‐Castaño
FGFaustino Gómez
Faustino Gómez
JPJuan Pardo-Montero
Juan Pardo-Montero

1 December 2019 in Cancer Research
Verified
Journal Article
Closed access
PDF file
PRPedro Rodríguez-Barbeito
Pedro Rodríguez-Barbeito
PDPablo Díaz-Botana
Pablo Díaz-Botana
MGMaría Araceli Gago-Arias
María Araceli Gago-Arias
MFManuel Feijoo
Manuel Feijoo
SNSara Neira
Sara Neira
JPJuan Pardo-Montero
Juan Pardo-Montero
There is increasing evidence that high doses of radiotherapy, like those delivered in stereotactic body radiotherapy (SBRT), trigger indirect mechanisms of cell death. Such effect seems to be two-fold. High doses may trigger an immune response and may cause vascular damage, leading to cell starvation and death. Development of mathematical response models, including indirect death, may help clinicians to design SBRT optimal schedules. Despite increasing experimental literature on indirect tumor cell death caused by vascular damage, efforts on modeling this effect have been limited. In this work, we present a biomathematical model of this effect. In our model, tumor oxygenation is obtained by solving the reaction–diffusion equation; radiotherapy kills tumor cells according to the linear–quadratic model, and also endothelial cells (EC), which can trigger loss of functionality of capillaries. Capillary death will affect tumor oxygenation, driving nearby tumor cells into severe hypoxia. Capillaries can recover functionality due to EC proliferation. Tumor cells entering a predetermined severe hypoxia status die according to a hypoxia-death model. This model fits recently published experimental data showing the effect of vascular damage on surviving fractions. It fits surviving fraction curves and qualitatively reproduces experimental values of percentages of functional capillaries 48 hours postirradiation, and hypoxic cells pre- and 48 hours postirradiation. This model is useful for exploring aspects of tumor and EC response to radiotherapy and constitutes a stepping stone toward modeling indirect tumor cell death caused by vascular damage and accounting for this effect during SBRT planning. Significance: A novel biomathematical model of indirect tumor cell death caused by vascular radiation damage could potentially help clinicians interpret experimental data and design better radiotherapy schedules.

22 June 2020 in Medical Physics
Verified
Journal Article
Open access
PDF file
SCSara Neira Castro
Sara Neira Castro
JGJacobo Guiu‐Souto
Jacobo Guiu‐Souto
PDPablo Díaz‐Botana
Pablo Díaz‐Botana
PPPaulino Pais
Paulino Pais
CFCarlos Fernández
Carlos Fernández
JPJuan Pardo-Montero
Juan Pardo-Montero
Purpose: The purpose of this work is to calculate individualized dose distributions in patients undergoing 18F‐FDG PET/CT studies through a methodology based on full Monte Carlo (MC) simulations and PET/CT patient images, and to compare such values with those obtained by employing nonindividualized phantom‐based methods.Methods: We developed a MC‐based methodology for individualized internal dose calculations, which relies on CT images (for organ segmentation and dose deposition), PET images (for organ segmentation and distributions of activities), and a biokinetic model (which works with information provided by PET and CT images) to obtain cumulated activities. The software vGATE version 8.1. was employed to carry out the Monte Carlo calculations. We also calculated deposited doses with nonindividualized phantom‐based methods (Cristy–Eckerman, Stabin, and ICRP‐133).Results: Median MC‐calculated dose/activity values are within 0.01–0.03 mGy/MBq for most organs, with higher doses delivered especially to the bladder wall, major vessels, and brain (medians of 0.058, 0.060, 0.066 mGy/MBq, respectively). Comparison with values obtained with nonindividualized phantom‐based methods has shown important differences in many cases (ranging from −80% to + 260%). These differences are significant (p < 0.05) for several organs/tissues, namely, remaining tissues, adrenals, bladder wall, bones, upper large intestine, heart, pancreas, skin, and stomach wall.Conclusions: The methodology presented in this work is a viable and useful method to calculate internal dose distributions in patients undergoing medical procedures involving radiopharmaceuticals, individually, with higher accuracy than phantom‐based methods, fulfilling the guidelines provided by the European Council directive 2013/59/Euratom.

20 January 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
MGMaría Araceli Gago-Arias
María Araceli Gago-Arias
PAPablo Aguiar
Pablo Aguiar
IEIgnacio Espinoza
Ignacio Espinoza
BSBeatriz Sánchez-Nieto
Beatriz Sánchez-Nieto
JPJuan Pardo-Montero
Juan Pardo-Montero
The resistance of hypoxic cells to radiation, due to the oxygen dependence of radiosensitivity, is well known and must be taken into account to accurately calculate the radiation induced cell death. A proper modelling of the response of tumours to radiation requires deriving the distribution of oxygen at a microscopic scale. This usually involves solving the reaction-diffusion equation in tumour voxels using a vascularization distribution model. Moreover, re-oxygenation arises during the course of radiotherapy, one reason being the increase of available oxygen caused by cell killing, which can turn hypoxic tumours into oxic. In this work we study the effect of cell death kinetics in tumour oxygenation modelling, analysing how it affects the timing of re-oxygenation, surviving fraction and tumour control. Two models of cell death are compared, an instantaneous cell killing, mimicking early apoptosis, and a delayed cell death scenario in which cells can die shortly after being damaged, as well as long after irradiation. For each of these scenarios, the decrease in oxygen consumption due to cell death can be computed globally (macroscopic voxel average) or locally (microscopic). A re-oxygenation model already used in the literature, the so called full re-oxygenation , is also considered. The impact of cell death kinetics and re-oxygenation on tumour responses is illustrated for two radiotherapy fractionation schemes: a conventional schedule, and a hypofractionated treatment. The results show large differences in the doses needed to achieve 50% tumour control for the investigated cell death models. Moreover, the models affect the tumour responses differently depending on the treatment schedule. This corroborates the complex nature of re-oxygenation, showing the need to take into account the kinetics of cell death in radiation response models.