Jigang Wang

Jigang Wang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2018 in Particles
Verified
Journal Article
Open access
PDF file
RHRuixuan Huang
Ruixuan Huang
WLWeiwei Li
Weiwei Li
ZZZhouyu Zhao
Zhouyu Zhao
HLHeting Li
Heting Li
JWJigang Wang
Jigang Wang
Yalin LuYalin Lu
Yalin Lu
Terahertz (THz) radiation has attracted much attention in new scientific and industrial applications. There has been significant recent progress in generating THz with accelerators. To investigate the collective behavior of electron dynamics, we have proposed a new high throughput material characterization system, which supplies a multiple light source. The system includes a pre-bunched THz free electron laser (FEL), which is a high-power narrow-band THz source with a wide tuning range of frequency. The physical design with the main components of the facility is introduced, and the simulation results are illustrated. Radiation of 0.5–3.0 THz is obtained by the fundamental wave of the pre-bunched beam, and radiation covering 3.0–5.0 THz is realized by second harmonic generation. As the simulation shows, intense THz radiation could be achieved in a frequency from 0.5–5.0 THz, with a peak power of several megawatts (MWs) and a bandwidth of a few percent.

13 May 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYunkun Zhao
Yunkun Zhao
SJSanshuang Jin
Sanshuang Jin
FWFangfang Wu
Fangfang Wu
TZTianyu Zhou
Tianyu Zhou
PLPing Lu
Ping Lu
BSBaogen Sun
Baogen Sun
In this study, a simple suitable temporal beam characteristic parameter extraction method is developed to measure the longitudinal coupling impedance of the Hefei Light Source-II (HLS-II). In the experiment, a streak camera is applied to observe the potential-well distortion under single-bunch operation mode and then accurately measure the longitudinal impedance of machine. According to the theoretical analytical model and in combination with the measured longitudinal bunch behaviors, the inductive, resistive, and longitudinal broadband impedance of the HLS-II storage ring are obtained as 107±28 nH, 1430±242 Ω, and 1.009±0.013 Ω respectively, for the normal operating radio-frequency (RF) accelerating voltage of 122.8 kV. It is concluded that the effective longitudinal coupling impedance of HLS-II is calculated to be 3.05±0.80 Ω. Additionally, the bunch lengthening factor Bl and asymmetry factor A of longitudinal bunch distribution are also measured experimentally in various RF voltages so as to further research nonlinear longitudinal beam dynamics and beam evolution associated with bunch behaviors. Then, the applicability, feasibility and reliability of this proposed method are also verified. When the RF voltage is adjusted to 100.4, 110.3, 130.4, and 140.5 kV, the inductive impedance of machine is estimated to be 115±13, 107±17, 105±31, and 108±28 nH, respectively. And the according resistive impedance is 1320±310, 1380±214, 1360±230, and 1300±260 Ω, respectively. Through a series of experimental measurements, it has demonstrated the validity and accuracy of the measured longitudinal impedances of HLS-II, of which agree well with the simulated results.

4 May 2022 in International Journal of Optomechatronics
Verified
Journal Article
Open access
SJSanshuang Jin
Sanshuang Jin
YZYunkun Zhao
Yunkun Zhao
BSBaogen Sun
Baogen Sun
LTLeilei Tang
Leilei Tang
FWFangfang Wu
Fangfang Wu
JWJigang Wang
Jigang Wang
In this paper, a horizontal and vertical double-slits interferometer using visible light are designed to measure the transverse beam size of Hefei Light Source II (HLS-II). For the given initial structural parameters of the two interferometers, a series of numerical simulations and analyses are carried out by using the Synchrotron Radiation Workshop (SRW) code. Furthermore, the core parameters of the double-slits components in the interferometers are optimized. In the end, the visibilities of the horizontal and vertical interferometer we designed are 0.345 and 0.548 respectively, which are in the range of 0.2–0.6. And simulation results meet the requirement of theoretical relative measurement error of less than 10%.

Verified
Conference Paper
Open access
YZYunkun Zhao
Yunkun Zhao
SJSanshuang Jin
Sanshuang Jin
Ping LuPing Lu
Ping Lu
BSBaogen Sun
Baogen Sun
JWJigang Wang
Jigang Wang
TZTianyu Zhou
Tianyu Zhou
The dual-axial scan streak camera plays an important role in the super-fast optical measurement and the beam diagnosis of the accelerators. Indeed, the development of the synchrotron light measurement system by virtue of the streak camera provides an effective tool and research platform for accelerator physics and super-fast optical phenomenon. In this paper, the configuration of the streak camera measurement system is roughly described. And the experimental researches are simultaneously performed, including the bunch lengthening, the potential-well distortion, the longitudinal bunch oscillations, and the beam evolution during the single bunch operation mode in the HLS-II storage ring. Moreover, the effects of the RF modulation on the beam lifetime and longitudinal bunch beam dynamics are carried out.

3 August 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MMMingdong Ma
Mingdong Ma
YLYongbin Leng
Yongbin Leng
JWJigang Wang
Jigang Wang
XMXiaochao Ma
Xiaochao Ma

27 March 2022
Verified
Conference Paper
Closed access
PDF file
SJSan-Shuang Jin
San-Shuang Jin
YZYunkun Zhao
Yunkun Zhao
BSBaogen Sun
Baogen Sun
JWJigang Wang
Jigang Wang
TZTianyu Zhou
Tianyu Zhou
LTLeiLei Tang
LeiLei Tang
A quad-slits interferometer using visible light is designed to measure the transverse beam-profile of Hefei Light SourceII (HLS-II). On the basis of the basic beam parameters of the B7 source point, the preliminary simulation results are obtained by using the Synchrotron Radiation Workshop (SRW) code. In addition, the core parameters of the quad-slits component in the interferometer are further optimized.