Nawal Alharbi

Dr. Nawal Alharbi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
NANawal Alharbi
Nawal Alharbi
ROReham Osman
Reham Osman
DWDaniel Wismeijer
Daniel Wismeijer

1 November 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
ROReham B. Osman
Reham B. Osman
AVAlbert J. van der Veen
Albert J. van der Veen
DHDennis Huiberts
Dennis Huiberts
DWDaniel Wismeijer
Daniel Wismeijer
NANawal Alharbi
Nawal Alharbi

1 April 2018 in Journal of Prosthodontic Research
Verified
Journal Article
Closed access
NANawal Alharbi
Nawal Alharbi
SASaud Alharbi
Saud Alharbi
VCVincent M.J.I. Cuijpers
Vincent M.J.I. Cuijpers
ROReham B. Osman
Reham B. Osman
DWDaniel Wismeijer
Daniel Wismeijer
PurposeTo evaluate the influence of fabrication method and finish line design on marginal and internal fit of full-coverage interim restorations. MethodsFour typodont models of maxillary central-incisor were prepared for full-coverage restorations. Four groups were defined; knife-edge (KE), chamfer (C), rounded-shoulder (RS), rounded-shoulder with bevel (RSB). All preparations were digitally scanned. A total of 80 restorations were fabricated; 20 per group (SLA/3D-printed n=10, milled n=10). All restorations were positioned on the master die and scanned using micro-computed tomography. The mean gaps were measured digitally (ImageJ). The results were compared using MANOVA (α=.05). ResultsInternal and marginal gaps were significantly influenced by fabrication method (P=.000) and finish-line design (P=.000). 3D-Printed restorations showed statistically significant lower mean gap compared to milled restorations at all points (P=.000). The mean internal gap for 3D-printed restorations were 66, 149, 130, 95μm and for milled restorations were 89, 177, 185, 154μm for KE, C, RS, RSB respectively. The mean absolute marginal discrepancy in 3D-printed restorations were (30, 41, 30, 28μm) and in milled restorations were (56, 54, 52, 38μm) for KE, C, RS, RSB respectively. ConclusionsThe fabrication methods showed more of an influence on the fit compared to the effect of the finish-line design in both milled and printed restorations. SLA-printed interim restorations exhibit lower marginal and internal gap than milled restorations. Nonetheless, for both techniques, all values were within the reported values for CAD/CAM restorations. Significance3D-printing can offer an alternative fabrication method comparable to those of milled restorations.

27 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
NANawal Alharbi
Nawal Alharbi
AAAmal Alharbi
Amal Alharbi
ROReham Osman
Reham Osman
Recent burgeoning development in material science has introduced a 3D-printable, nanohybrid composite resin restorative material. However, its performance has not yet been investigated. This study evaluates the stain susceptibility and efficacy of different stain removal techniques. A total of 120 labial veneers were fabricated using milling (n = 60) and SLA 3D-printing (n = 60). Based on the immersion media: coffee, tea and artificial saliva, each group was divided into three sub-groups (n = 20). Stain susceptibility was evaluated by calculating color difference (∆E00) at 12 and 24 days using a spectrophotometer against black and white backgrounds. Collected data were analyzed with ANOVA and Tukey’s post hoc test (p < 0.05). A significant interaction effect was found between the staining mediums and fabrication methods in both black and white backgrounds (p < 0.001). 3D-printed restorations showed significantly higher stain susceptibility than milled restorations (p < 0.001). Prolonged immersion time increased the color difference in both groups. In-office bleaching was more effective in stain removal in both 3D-printed and milled restoration groups. The susceptibility of the presented novel 3D-printed restorative material to color changes in different immersion mediums was clinically not-acceptable. The clinicians might expect the need to replace the restoration after 1–2 years and thus, recommendation for the use of such a material as a permanent restoration cannot be made but rather as a long-term temporary restoration.

10 April 2023 in Polymers
Verified
Journal Article
Open access
PDF file
ROReham Osman
Reham Osman
GKghalia khoder
ghalia khoder
BFBahgat Fayed
Bahgat Fayed
RKReena Arora Kedia
Reena Arora Kedia
YEYaser Elkareimi
Yaser Elkareimi
NANawal Alharbi
Nawal Alharbi
The aim of this study was to evaluate the adhesion and biofilm formation of Candida albicans (C. albicans) on conventionally fabricated, milled, and 3D-printed denture base resin materials in order to determine the susceptibility of denture contamination during clinical use. Specimens were incubated with C. albicans (ATCC 10231) for 1 and 24 h. Adhesion and biofilm formation of C. albicans were assessed using the field emission scanning electron microscopy (FESEM). The XTT (2,3-(2-methoxy-4-nitro-5-sulphophenyl)-5-[(phenylamino) carbonyl]-2H-tetrazolium hydroxide) assay was used for the quantification of fungal adhesion and biofilm formation. The data were analyzed using GraphPad Prism 8.02 for windows. One-way ANOVA with Tukey’s post hoc testing were performed with a statistical significance level set at α = 0.05. The quantitative XTT biofilm assay revealed significant differences in the biofilm formation of C. albicans between the three groups in the 24 h incubation period. The highest proportion of biofilm formation was observed in the 3D-printed group, followed by the conventional group, while the lowest candida biofilm formation was observed in the milled group. The difference in biofilm formation among the three tested dentures was statistically significant (p < 0.001). The manufacturing technique has an influence on the surface topography and microbiological properties of the fabricated denture base resin material. Additive 3D-printing technology results in increased candida adhesion and the roughest surface topography of maxillary resin denture base as compared to conventional flask compression and CAD/CAM milling techniques. In a clinical setting, patients wearing additively manufactured maxillary complete dentures are thus more susceptible to the development of candida-associated denture stomatitis and accordingly, strict oral hygiene measures and maintenance programs should be emphasized to patients.