Gwang Hoon Rhee

Prof. Dr. Gwang Hoon Rhee


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2016 in Energies
Verified
Journal Article
Open access
PDF file
JPJinsoo Park
Jinsoo Park
JCJung-Il Choi
Jung-Il Choi
GRGwang Hoon Rhee
Gwang Hoon Rhee
Enhancing the ventilation performance of energy-efficient buildings with single-sided openings is important because their ventilation performance is poor and strongly depends on the wind conditions. We considered an overhang as a potential building façade for improving the single-sided ventilation performance. We performed numerical simulations of three-dimensional unsteady turbulent flows over an idealized building with an overhang in order to investigate the effect of the overhang on the ventilation performance. Parametric studies were systematically carried out where the overhang length, wind speed, and wind direction were varied. The numerical results showed that the overhang drastically enhanced the ventilation rate in the windward direction regardless of the wind speed. This is because, for windward cases, the overhang produces a vortex with strong flow separation near the tip of the overhang, which promotes a net airflow exchange at the entrance and increases the ventilation rate. However, the ventilation rates for the leeward and side cases are slightly decreased with the overhang. Using an overhang with single-sided ventilation greatly reduces the local mean age of air (LMA) in the windward direction but increases it in the leeward direction.

3 December 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Young-Min KimYoung-Min Kim
Young-Min Kim
SPSumin Pyo
Sumin Pyo
HHHanie Hakimian
Hanie Hakimian
KYKyung-Seun Yoo
Kyung-Seun Yoo
GRGwang Hoon Rhee
Gwang Hoon Rhee
Young-Kwon ParkYoung-Kwon Park
Young-Kwon Park
A kinetic analysis of non-catalytic pyrolysis (NCP) and catalytic pyrolysis (CP) of polypropylene (PP) with different catalysts was performed using thermogravimetric analysis (TGA) and kinetic models. Three kinds of low-cost natural catalysts were used to maximize the cost-effectiveness of the process: natural zeolite (NZ), bentonite, olivine, and a mesoporous catalyst, Al-MCM-41. The decomposition temperature of PP and apparent activation energy (Ea) were obtained from the TGA results at multiple heating rates, and a model-free kinetic analysis was performed using the Flynn–Wall–Ozawa model. TGA indicated that the maximum decomposition temperature (Tmax) of the PP was shifted from 464 °C to 347 °C with Al-MCM-41 and 348 °C with bentonite, largely due to their strong acidity and large pore size. Although olivine had a large pore size, the Tmax of PP was only shifted to 456 °C, because of its low acidity. The differential TG (DTG) curve of PP over NZ revealed a two-step mechanism. The Tmax of the first peak on the DTG curve of PP with NZ was 376 °C due to the high acidity of NZ. On the other hand, that of the second peak was higher (474 °C) than the non-catalytic reaction. The Ea values at each conversion were also decreased when using the catalysts, except olivine. At <0.5 conversion, the Ea obtained from the CP of PP with NZ was lower than that with the other catalysts: Al-MCM-41, bentonite, and olivine, in that order. The Ea for the CP of PP with NZ increased more rapidly, to 193 kJ/mol at 0.9 conversion, than the other catalysts.

17 December 2017 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
JPJinsoo Park
Jinsoo Park
GRGwang Hoon Rhee
Gwang Hoon Rhee

7 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
DKDAE HYUN KIM
DAE HYUN KIM
HLHyunmuk Lim
Hyunmuk Lim
JMJongmin Moon
Jongmin Moon
JPJinsoo Park
Jinsoo Park
GRGwang Hoon Rhee
Gwang Hoon Rhee
Workshops with a large area and a high ceiling height without compartments, such as large-scale assembly factories, have an uneven thermal comfort during heating, making it difficult to establish an effective heating strategy. In this study, we evaluate the heating performance of a large-scale factory based on thermal comfort and energy flow and discuss effective heating methods. In addition, an analysis of the heating performance of a large-scale factory is attempted for the first time. To analyze the heating performance, computational fluid dynamics (CFD) and building energy simulation (BES) were used to confirm thermal comfort distribution and energy flow in a large-scale factory. Temperature distribution and thermal comfort were evaluated through CFD, and the temperature of a large-scale assembly factory was compared with experimental data. Based on the CFD results, the current heating level of large factories was predicted to be 15.4 °C, and the ADPIrev was 70%. Moreover, the BES results show that the energy losses due to forced ventilation and the inflow of outside air contributed 35.5% and 27.8%, respectively. The heating strategy proposed in this study could improve thermal comfort by 79% compared to the same energy consumption. Therefore, to improve the heating performance compared to the heating energy consumption of large-scale factory, the imbalance in thermal comfort caused by the inflow of outside air must be resolved.

5 September 2024 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
DHDong Hee Hong
Dong Hee Hong
SKSi Heon Kim
Si Heon Kim
SKSarng Woo Karng
Sarng Woo Karng
GRGwang Hoon Rhee
Gwang Hoon Rhee

1 January 2007
Verified
Conference Paper
Closed access
PDF file
TJTae Ho Ji
Tae Ho Ji
SKSeo Young Kim
Seo Young Kim
JHJae Min Hyun
Jae Min Hyun
GRGwang Hoon Rhee
Gwang Hoon Rhee
Experiments are performed to investigate heat transfer enhancement from a heated square cylinder in a channel by pulsating flow. For all the experiments, the amplitude of the pulsating flow is fixed at A = 0.05. The effects of the pulsating frequency (0 Hz < fp < 60 Hz) and the blockage ratio of the square cylinder (β = 1/10, 1/8, and 1/6) on convective heat transfer are examined. The “lock-on” phenomenon is clearly observed for a square cylinder in the present flow pulsation. The influence of blockage ratio on heat transfer enhancement is examined. The experimental results show that as the blockage ratio decreases, the heat transfer enhancement is more pronounced and lock-on regime broadens.