Jacques G. Verly

Dr. Jacques G. Verly


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AHAnaïs Halin
Anaïs Halin
JVJacques G. Verly
Jacques G. Verly
MDMarc Van Droogenbroeck
Marc Van Droogenbroeck
Road vehicle accidents are mostly due to human errors, and many such accidents could be avoided by continuously monitoring the driver. Driver monitoring (DM) is a topic of growing interest in the automotive industry, and it will remain relevant for all vehicles that are not fully autonomous, and thus for decades for the average vehicle owner. The present paper focuses on the first step of DM, which consists of characterizing the state of the driver. Since DM will be increasingly linked to driving automation (DA), this paper presents a clear view of the role of DM at each of the six SAE levels of DA. This paper surveys the state of the art of DM, and then synthesizes it, providing a unique, structured, polychotomous view of the many characterization techniques of DM. Informed by the survey, the paper characterizes the driver state along the five main dimensions—called here “(sub)states”—of drowsiness, mental workload, distraction, emotions, and under the influence. The polychotomous view of DM is presented through a pair of interlocked tables that relate these states to their indicators (e.g., the eye-blink rate) and the sensors that can access each of these indicators (e.g., a camera). The tables factor in not only the effects linked directly to the driver, but also those linked to the (driven) vehicle and the (driving) environment. They show, at a glance, to concerned researchers, equipment providers, and vehicle manufacturers (1) most of the options they have to implement various forms of advanced DM systems, and (2) fruitful areas for further research and innovation.

19 November 2007 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
SGSebastien Greve
Sebastien Greve
PRPhilippe Ries
Philippe Ries
FLFabian Lapierre
Fabian Lapierre
JVJacques G. Verly
Jacques G. Verly
The goal of radar space-time adaptive processing (STAP) is to detect slow moving targets from a moving platform, typically airborne or spaceborne. STAP generally requires the estimation and the inversion of an interference-plus-noise (I+N) covariance matrix. To reduce both the number of samples involved in the estimation and the computational cost inherent to the matrix inversion, many suboptimum STAP methods have been proposed. We propose a new canonical framework that encompasses all suboptimum STAP methods we are aware of. The framework allows for both covariance-matrix (CM) estimation and range-dependence compensation (RDC); it also applies to monostatic and bistatic configurations. Finally, we discuss a taxonomy for classifying the methods described by the framework.

25 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
QMQuentin Massoz
Quentin Massoz
JVJacques G. Verly
Jacques G. Verly
MDMarc Van Droogenbroeck
Marc Van Droogenbroeck
Drowsiness is a major cause of fatal accidents, in particular in transportation. It is therefore crucial to develop automatic, real-time drowsiness characterization systems designed to issue accurate and timely warnings of drowsiness to the driver. In practice, the least intrusive, physiology-based approach is to remotely monitor, via cameras, facial expressions indicative of drowsiness such as slow and long eye closures. Since the system’s decisions are based upon facial expressions in a given time window, there exists a trade-off between accuracy (best achieved with long windows, i.e., at long timescales) and responsiveness (best achieved with short windows, i.e., at short timescales). To deal with this trade-off, we develop a multi-timescale drowsiness characterization system composed of four binary drowsiness classifiers operating at four distinct timescales (5 s, 15 s, 30 s, and 60 s) and trained jointly. We introduce a multi-timescale ground truth of drowsiness, based on the reaction times (RTs) performed during standard Psychomotor Vigilance Tasks (PVTs), that strategically enables our system to characterize drowsiness with diverse trade-offs between accuracy and responsiveness. We evaluated our system on 29 subjects via leave-one-subject-out cross-validation and obtained strong results, i.e., global accuracies of 70%, 85%, 89%, and 94% for the four classifiers operating at increasing timescales, respectively.

19 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MBMohamed Boutaayamou
Mohamed Boutaayamou
DPDoriane Pelzer
Doriane Pelzer
CSCédric Schwartz
Cédric Schwartz
SGSophie Gillain
Sophie Gillain
GGGaëtan Garraux
Gaëtan Garraux
OBOlivier Bruls
Olivier Bruls
While inertial measurement unit (IMU)-based systems have shown their potential in quantifying medically significant gait parameters, it remains to be determined whether they can provide accurate and reliable parameters both across various walking conditions and in healthcare settings. Using an IMU-based system we previously developed, with one IMU module on each subject’s heel, we quantify the gait parameters of 55 men and 46 women, all healthy and aged 40–65, in normal, dual-task, and fast walking conditions. We evaluate their intra-session reliability, and we establish a new reference database of such parameters showing good to excellent reliability. ICC(2,1) assesses relative reliability, while SEM% and MDC% assess absolute reliability. The reliability is excellent for all spatiotemporal gait parameters and the stride length (SL) symmetry ratio (ICC ≥ 0.90, SEM% ≤ 4.5%, MDC% ≤ 12.4%) across all conditions. It is good to excellent for the fast walking performance (FWP) indices of stride (Sr), stance (Sa), double-support (DS), and step (St) times; gait speed (GS); and the GS normalized to leg length (GSn1) and body height (GSn2) (ICC ≥ 0.91, |SEM%| ≤ 10.0%, |MDC%| ≤ 27.6%). Men have a higher swing time (Sw) and SL across all conditions. The following parameters are gender-independent: (1) Sa, DS, GSn1, GSn2; (2) the symmetry ratios of SL and GS, as well as Sa% and Sw% (representing Sa and Sw as percentages of Sr); and (3) the FWPs of Sr, Sa, Sw, DS, St, cadence, Sa% and Sw%. Our results provide reference values with new insights into gender FWP comparisons rarely reported in the literature. The advantages and reliability of our IMU-based system make it suitable in medical applications such as prosthetic evaluation, fall risk assessment, and rehabilitation.

6 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
MBMohamed Boutaayamou
Mohamed Boutaayamou
DPDoriane Pelzer
Doriane Pelzer
CSCédric Schwartz
Cédric Schwartz
SGSophie Gillain
Sophie Gillain
GGGaëtan Garraux
Gaëtan Garraux
OBOlivier Bruls
Olivier Bruls
While inertial measurement unit (IMU)-based systems have shown their potential in quantifying medically-significant gait parameters, it remains to be demonstrated that they can provide accurate and reliable parameters both across various walking conditions and in healthcare settings. Using an IMU-based system we have previously developed, with one IMU module on each subject’s heel, we quantify gait parameters in 55 men and 46 women, all healthy and aged 40-65, in normal, dual-task, and fast-walking conditions. We evaluate their intra-session reliability, and we establish a new reference database of such parameters showing good to excellent reliability. ICC(2,1) assesses relative reliability, while SEM% and MDC% evaluate absolute reliability. The reliability is excellent for all spatiotemporal gait parameters and stride length (SL) symmetry ratio (ICC≥0.90, SEM%≤4.5%, MDC%≤12.4%) across all conditions. It is good to excellent for fast-walking performance (FWP) indices of stride (Sr), stance (Sa), double-support (DS), and step (St) times; gait speed (GS), and GS normalized to leg length (GSn1) and body height (GSn2) (ICC≥0.91, |SEM%|≤10.0%, |MDC%|≤27.6%). Men have higher swing time (Sw) and SL across all conditions. The following parameters are gender-independent: (1) Sa, DS, GSn1, GSn2; (2) symmetry ratios of Sa, Sa ratio (Sa%), Sw, Sw ratio (Sw%), SL, GS; and (3) FWPs of Sr, Sa, Sw, DS, St, cadence, Sa%, Sw%. Our results provide reference values with new insights into gender FWP comparisons rarely reported in the literature. The advantages and reliability of our IMU-based system make it suitable in medical applications such as prosthetic evaluation, fall-risk assessment, and rehabilitation.

1 June 2010
Verified
Conference Paper
Open access
SPSebastien Pierard
Sebastien Pierard
VPVincent Pierlot
Vincent Pierlot
OBOlivier Barnich
Olivier Barnich
MDMarc Van Droogenbroeck
Marc Van Droogenbroeck
JVJacques G. Verly
Jacques G. Verly
Interactivity is one of the key challenges for immersive applications like gaming. Manufacturers have been working towards interfaces that are driven by a device (e.g. a Wiimote) or interfaces that are controlled by a camera with a subsequent computer vision module. Both approaches have unique advantages, but they do not permit to localize users in the scene with an appropriate accuracy. Therefore, we propose to use both a range camera and accurate range sensors to enable the interpretation of movements. This paper describes a platform that uses a range camera to acquire the silhouettes of users, regardless of illumination, and to improve the pose recovery with range information after some image processing steps. In addition, to circumvent the difficult process of calibration required to map range values to physical distances, we complete the system with several range laser sensors. These sensors are located in a horizontal plane, and measure distances up to a few centimeters. We combine all these measurements to obtain a localization map, used to locate users in the scene at a negligible computational cost. Our method fills a gap in 3D applications that require absolute positions.