Angelos Karlas

Dr. Angelos Karlas


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZJZhongliang Jiang
Zhongliang Jiang
XLXuesong Li
Xuesong Li
XCXiangyu Chu
Xiangyu Chu
AKAngelos Karlas
Angelos Karlas
YBYuan Bi
Yuan Bi
NNNassir Navab
Nassir Navab
Ultrasound-guided percutaneous needle insertion is a standard procedure employed in both biopsy and ablation in clinical practices. However, due to the complex interaction between tissue and instrument, the needle may deviate from the in-plane view, resulting in a lack of close monitoring of the percutaneous needle. To address this challenge, we introduce a robot-assisted ultrasound (US) imaging system designed to seamlessly monitor the insertion process and autonomously restore the visibility of the inserted instrument when misalignment happens. To this end, the adversarial structure is presented to encourage the generation of segmentation masks that align consistently with the ground truth in high-order space. This study also systematically investigates the effects on segmentation performance by exploring various training loss functions and their combinations. When misalignment between the probe and the percutaneous needle is detected, the robot is triggered to perform transverse searching to optimize the positional and rotational adjustment to restore needle visibility. The experimental results on ex-vivo porcine samples demonstrate that the proposed method can precisely segment the percutaneous needle (with a tip error of 0.37 ± 0.29 mm and an angle error of 1.19 ± 0.29°). Furthermore, the needle appearance can be successfully restored under the repositioned probe pose in all 45 trials, with repositioning errors of 1.51 ± 0.95 mm and 1.25 ± 0.79°.

25 February 2025 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
DHDianye Huang
Dianye Huang
CLChenyang Li
Chenyang Li
AKAngelos Karlas
Angelos Karlas
XCXiangyu Chu
Xiangyu Chu
KAK. W. Samuel Au
K. W. Samuel Au
ZJZhongliang Jiang
Zhongliang Jiang
Precise percutaneous needle detection is crucial for ultrasound (US)-guided interventions. However, inherent limitations such as speckles, needle-like artifacts, and low resolution make it challenging to robustly detect needles, especially when their visibility is reduced or imperceptible. To address this challenge, we propose VibNet, a learning-based framework designed to enhance the robustness and accuracy of needle detection in US images by leveraging periodic vibration applied externally to the needle shafts. VibNet integrates neural Short-Time Fourier Transform and Hough Transform modules to achieve successive sub-goals, including motion feature extraction in the spatiotemporal space, frequency feature aggregation, and needle detection in the Hough space. Due to the periodic subtle vibration, the features are more robust in the frequency domain than in the image intensity domain, making VibNet more effective than traditional intensity-based methods. To demonstrate the effectiveness of VibNet, we conducted experiments on distinct ex vivo porcine and bovine tissue samples. The results obtained on porcine samples demonstrate that VibNet effectively detects needles even when their visibility is severely reduced, with a tip error of 1.61±1.56 mm compared to 8.15±9.98 mm for UNet and 6.63±7.58 mm for WNet, and a needle direction error of 1.64 ± 1.86° compared to 9.29 ± 15.30° for UNet and 8.54 ± 17.92° for WNet. Code: https://github.com/marslicy/VibNet.

Verified
Journal Article
Open access
PDF file
KHKaveh Hosseini
Kaveh Hosseini
HSHamidreza Soleimani
Hamidreza Soleimani
ANAmir Nasrollahizadeh
Amir Nasrollahizadeh
YJYaser Jenab
Yaser Jenab
AKAngelos Karlas
Angelos Karlas
PKPolydoros Kampaktsis
Polydoros Kampaktsis
Background: Transcatheter edge-to-edge repair (TEER) of the mitral valve (MV) can be performed using the PASCAL or MitraClip devices. Few studies offer a head-to-head outcome comparison of these two devices. Material and Methods: PubMed, EMBASE, Cochrane Library, Clinicaltrials.gov and WHO’s International Clinical Trials Registry Platform, from 1 January 2000 until 1 March 2023, were searched. Study protocol details were registered in the International Prospective Register of Systematic Reviews (PROSPERO ID: CRD42023405400). Randomized Controlled Trials and observational studies reporting head-to-head clinical comparison of PASCAL and MitraClip devices were eligible for selection. Patients with severe functional or degenerative mitral regurgitation (MR) who had undergone TEER of the MV with either PASCAL or MitraClip devices were included in the meta-analysis. Data from six studies (five observational and one randomized clinical trial) were extracted and analyzed. The main outcomes were a reduction in MR to 2+ or less, improvement of New York Heart Association (NYHA) and 30-day all-cause mortality. Peri-procedural mortality, success rate and adverse events were also compared. Results: Data from 785 and 796 patients that underwent TEER using PASCAL and MitraClip, respectively, were analyzed. Thirty-day all-cause mortality (Risk ratio [RR] = 1.51, 95% CI 0.79–2.89), MR reduction to maximum 2+ (RR = 1.00, 95% CI 0.98–1.02) and NYHA improvement (RR = 0.98, 95% CI 0.84–1.15) were similar in both device groups. Both devices had high and similar success rates (96.9% and 96.7% for the PASCAL and MitraClip group, respectively, p value = 0.91). MR reduction to 1+ or less at discharge was similar in both device groups (RR = 1.06, 95% CI 0.95–1.19). Composite peri-procedural and in-hospital mortality was 0.64% and 1.66% in the PASCAL and MitraClip groups, respectively (p value = 0.094). Rates of peri-procedural cerebrovascular accidents were 0.26% in PASCAL and 1.01% in MitraClip (p value = 0.108). Conclusions: Both PASCAL and MitraClip devices have high success and low complication rates for TEER of the MV. PASCAL was not inferior to MitraClip in reducing the MR level at discharge.

31 October 2024 in Photoacoustics
Verified
Journal Article
Open access
AKAngelos Karlas
Angelos Karlas
NKNikoletta Katsouli
Nikoletta Katsouli
NFNikolina-Alexia Fasoula
Nikolina-Alexia Fasoula
MRMario Reidl
Mario Reidl
RLRhiannon Lees
Rhiannon Lees
MKMichael Kallmayer
Michael Kallmayer
Microvascular endothelial dysfunction may provide insights into systemic diseases, such as carotid artery disease. Raster-scan optoacoustic mesoscopy (RSOM) can produce images of skin microvasculature during endothelial dysfunction challenges via numerous microvascular features. Herein, RSOM was employed to image the microvasculature of 26 subjects (13 patients with single carotid artery disease, 13 healthy participants) to assess the dynamics of 18 microvascular features at three scales of detail, i.e., the micro- (<100 μm), meso- (≈100–1000 μm) and macroscale (<1000 μm), during post-occlusive reactive hyperemia challenges. The proposed analysis identified a subgroup of 9 features as the most relevant to carotid artery disease because they achieved the most efficient classification (AUC of 0.93) between the two groups in the first minute of hyperemia (sensitivity/specificity: 0.92/0.85). This approach provides a non-invasive solution to microvasculature quantification in carotid artery disease, a main form of cardiovascular disease, and further highlights the possible link between systemic disease and microvascular dysfunction.

20 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
IDIoannis Dimaridis
Ioannis Dimaridis
PSPatmaa Sridharan
Patmaa Sridharan
VNVasilis Ntziachristos
Vasilis Ntziachristos
AKAngelos Karlas
Angelos Karlas
LHLeontios Hadjileontiadis
Leontios Hadjileontiadis
Optoacoustic imaging relies on the detection of optically induced acoustic waves to offer new possibilities in morphological and functional imaging. As the modality matures towards clinical application, research efforts aim to address multifactorial limitations that negatively impact the resulting image quality. In an endeavor to obtain a clear view on the limitations and their effects, as well as the status of this progressive refinement process, we conduct an extensive search for optoacoustic image quality improvement approaches that have been evaluated with humans in vivo, thus focusing on clinically relevant outcomes. We query six databases (PubMed, Scopus, Web of Science, IEEE Xplore, ACM Digital Library, and Google Scholar) for articles published from 1 January 2010 to 31 October 2021, and identify 45 relevant research works through a systematic screening process. We review the identified approaches, describing their primary objectives, targeted limitations, and key technical implementation details. Moreover, considering comprehensive and objective quality assessment as an essential prerequisite for the adoption of such approaches in clinical practice, we subject 36 of the 45 papers to a further in-depth analysis of the reported quality evaluation procedures, and elicit a set of criteria with the intent to capture key evaluation aspects. Through a comparative criteria-wise rating process, we seek research efforts that exhibit excellence in quality assessment of their proposed methods, and discuss features that distinguish them from works with similar objectives. Additionally, informed by the rating results, we highlight areas with improvement potential, and extract recommendations for designing quality assessment pipelines capable of providing rich evidence.

Verified
Journal Article
Open access
PDF file
NFNikolina-Alexia Fasoula
Nikolina-Alexia Fasoula
YXYi Xie
Yi Xie
NKNikoletta Katsouli
Nikoletta Katsouli
MRMario Reidl
Mario Reidl
MKMichael A. Kallmayer
Michael A. Kallmayer
AKAngelos Karlas
Angelos Karlas
Microvascular changes in diabetes affect the function of several critical organs, such as the kidneys, heart, brain, eye, and skin, among others. The possibility of detecting such changes early enough in order to take appropriate actions renders the development of appropriate tools and techniques an imperative need. To this end, several sensing and imaging techniques have been developed or employed in the assessment of microangiopathy in patients with diabetes. Herein, we present such techniques; we provide insights into their principles of operation while discussing the characteristics that make them appropriate for such use. Finally, apart from already established techniques, we present novel ones with great translational potential, such as optoacoustic technologies, which are expected to enter clinical practice in the foreseeable future.