Salvatore Claudio Fanni

Dr. Salvatore Claudio Fanni

Department of Clinical and Translational Sciences, University of Pisa, Pisa, Tuscany, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2024 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
BKBurak Kocak
Burak Kocak
TDTugba Akinci D'Antonoli
Tugba Akinci D'Antonoli
NMNathaniel Mercaldo
Nathaniel Mercaldo
AAAngel Alberich-Bayarri
Angel Alberich-Bayarri
BBBettina Baeßler
Bettina Baeßler
Renato CuocoloRenato Cuocolo
Renato Cuocolo
Purpose: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. Methods: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. Result: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. Conclusion: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. Critical relevance statement: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. Key points: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score (https://metricsscore.github.io/metrics/METRICS.html) and a repository created to collect feedback from the radiomics community (https://github.com/metricsscore/metrics). Graphical

8 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
GCGianvito Candita
Gianvito Candita
SRSara Rossi
Sara Rossi
KCKarolina Cwiklinska
Karolina Cwiklinska
Salvatore Claudio FanniSalvatore Claudio Fanni
Salvatore Claudio Fanni
Dania CioniDania Cioni
Dania Cioni
ENEmanuele Neri
Emanuele Neri
Hepatocellular carcinoma (HCC) remains not only a cause of a considerable part of oncologic mortality, but also a diagnostic and therapeutic challenge for healthcare systems worldwide. Early detection of the disease and consequential adequate therapy are imperative to increase patients’ quality of life and survival. Imaging plays, therefore, a crucial role in the surveillance of patients at risk, the detection and diagnosis of HCC nodules, as well as in the follow-up post-treatment. The unique imaging characteristics of HCC lesions, deriving mainly from the assessment of their vascularity on contrast-enhanced computed tomography (CT), magnetic resonance (MR) or contrast-enhanced ultrasound (CEUS), allow for a more accurate, noninvasive diagnosis and staging. The role of imaging in the management of HCC has further expanded beyond the plain confirmation of a suspected diagnosis due to the introduction of ultrasound and hepatobiliary MRI contrast agents, which allow for the detection of hepatocarcinogenesis even at an early stage. Moreover, the recent technological advancements in artificial intelligence (AI) in radiology contribute an important tool for the diagnostic prediction, prognosis and evaluation of treatment response in the clinical course of the disease. This review presents current imaging modalities and their central role in the management of patients at risk and with HCC.

18 July 2023 in European Journal of Radiology Open
Verified
Journal Article
Open access
EAEngy Abbas
Engy Abbas
Salvatore Claudio FanniSalvatore Claudio Fanni
Salvatore Claudio Fanni
CBClaudio Bandini
Claudio Bandini
RFRoberto Francischello
Roberto Francischello
MFMaria Febi
Maria Febi
ENEmanuele Neri
Emanuele Neri
The new immunotherapies have not only changed the oncological therapeutic approach but have also made it necessary to develop new imaging methods for assessing the response to treatment. Delta radiomics consists of the analysis of radiomic features variation between different medical images, usually before and after therapy. This review aims to evaluate the role of delta radiomics in the immunotherapy response assessment. A systematic search was performed in PubMed, Scopus, and Web Of Science using “delta radiomics AND immunotherapy” as search terms. The included articles' methodological quality was measured using the Radiomics Quality Score (RQS) tool. Thirteen articles were finally included in the systematic review. Overall, the RQS of the included studies ranged from 4 to 17, with a mean RQS total of 11,15 ± 4,18 with a corresponding percentage of 30.98 ± 11.61 %. Eleven articles out of 13 performed imaging at multiple time points. All the included articles performed feature reduction. No study carried out prospective validation, decision curve analysis, or cost-effectiveness analysis. Delta radiomics has been demonstrated useful in evaluating the response in oncologic patients undergoing immunotherapy. The overall quality was found law, due to the lack of prospective design and external validation. Thus, further efforts are needed to bring delta radiomics a step closer to clinical implementation.

1 January 2024 in Radiology: Artificial Intelligence
Verified
Journal Article
Open access
GSGianfranco Di Salle
Gianfranco Di Salle
LTLorenzo Tumminello
Lorenzo Tumminello
MLMaria Elena Laino
Maria Elena Laino
SSSherif Shalaby
Sherif Shalaby
GAGayane Aghakhanyan
Gayane Aghakhanyan
ENEmanuele Neri
Emanuele Neri
Purpose To perform a systematic review and meta-analysis assessing the predictive accuracy of radiomics in the noninvasive determination of isocitrate dehydrogenase (IDH) status in grade 4 and lower-grade diffuse gliomas. Materials and Methods A systematic search was performed in the PubMed, Scopus, Embase, Web of Science, and Cochrane Library databases for relevant articles published between January 1, 2010, and July 7, 2021. Pooled sensitivity and specificity across studies were estimated. Risk of bias was evaluated using Quality Assessment of Diagnostic Accuracy Studies-2, and methods were evaluated using the radiomics quality score (RQS). Additional subgroup analyses were performed according to tumor grade, RQS, and number of sequences used (PROSPERO ID: CRD42021268958). Results Twenty-six studies that included 3280 patients were included for analysis. The pooled sensitivity and specificity of radiomics for the detection of IDH mutation were 79% (95% CI: 76, 83) and 80% (95% CI: 76, 83), respectively. Low RQS scores were found overall for the included works. Subgroup analyses showed lower false-positive rates in very low RQS studies (RQS < 6) (meta-regression, z = -1.9; P = .02) compared with adequate RQS studies. No substantial differences were found in pooled sensitivity and specificity for the pure grade 4 gliomas group compared with the all-grade gliomas group (81% and 86% vs 79% and 79%, respectively) and for studies using single versus multiple sequences (80% and 77% vs 79% and 82%, respectively). Conclusion The pooled data showed that radiomics achieved good accuracy performance in distinguishing IDH mutation status in patients with grade 4 and lower-grade diffuse gliomas. The overall methodologic quality (RQS) was low and introduced potential bias. Keywords: Neuro-Oncology, Radiomics, Integration, Application Domain, Glioblastoma, IDH Mutation, Radiomics Quality Scoring Supplemental material is available for this article. Published under a CC BY 4.0 license.

10 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Salvatore Claudio FanniSalvatore Claudio Fanni
Salvatore Claudio Fanni
AMAlessandro Marcucci
Alessandro Marcucci
FVFederica Volpi
Federica Volpi
SVSalvatore Valentino
Salvatore Valentino
ENEmanuele Neri
Emanuele Neri
Chiara RomeiChiara Romei
Chiara Romei
Chest X-ray (CXR) is the most important technique for performing chest imaging, despite its well-known limitations in terms of scope and sensitivity. These intrinsic limitations of CXR have prompted the development of several artificial intelligence (AI)-based software packages dedicated to CXR interpretation. The online database “AI for radiology” was queried to identify CE-marked AI-based software available for CXR interpretation. The returned studies were divided according to the targeted disease. AI-powered computer-aided detection software is already widely adopted in screening and triage for pulmonary tuberculosis, especially in countries with few resources and suffering from high a burden of this disease. AI-based software has also been demonstrated to be valuable for the detection of lung nodules detection, automated flagging of positive cases, and post-processing through the development of digital bone suppression software able to produce digital bone suppressed images. Finally, the majority of available CE-marked software packages for CXR are designed to recognize several findings, with potential differences in sensitivity and specificity for each of the recognized findings.

1 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
GAGiacomo Aringhieri
Giacomo Aringhieri
Salvatore Claudio FanniSalvatore Claudio Fanni
Salvatore Claudio Fanni
MFMaria Febi
Maria Febi
LCLeonardo Colligiani
Leonardo Colligiani
Dania CioniDania Cioni
Dania Cioni
ENEmanuele Neri
Emanuele Neri
Background: Radiomics of salivary gland imaging can support clinical decisions in different clinical scenarios, such as tumors, radiation-induced xerostomia and sialadenitis. This review aims to evaluate the methodological quality of radiomics studies on salivary gland imaging. Material and Methods: A systematic search was performed, and the methodological quality was evaluated using the radiomics quality score (RQS). Subgroup analyses according to the first author’s professional role (medical or not medical), journal type (radiological journal or other) and the year of publication (2021 or before) were performed. The correlation of RQS with the number of patients was calculated. Results: Twenty-three articles were included (mean RQS 11.34 ± 3.68). Most studies well-documented the imaging protocol (87%), while neither prospective validations nor cost-effectiveness analyses were performed. None of the included studies provided open-source data. A statistically significant difference in RQS according to the year of publication was found (p = 0.009), with papers published in 2021 having slightly higher RQSs than older ones. No differences according to journal type or the first author’s professional role were demonstrated. A moderate relationship between the overall RQS and the number of patients was found. Conclusions: Radiomics application in salivary gland imaging is increasing. Although its current clinical applicability can be affected by the somewhat inadequate quality of the papers, a significant improvement in radiomics methodologies has been demonstrated in the last year.