Mortality due to cardiovascular disease rises sharply in winter. Known as excess winter mortality, this phenomenon is partially explained by cold exposure-induced high blood pressure. Home blood pressure, especially in the morning, is closely associated with cardiovascular disease risk. We conducted the first large nationwide survey on home blood pressure and indoor temperature in 3775 participants (2095 households) who intended to conduct insulation retrofitting and were recruited by construction companies. Home blood pressure was measured twice in the morning and evening for 2 weeks. The relationship between home blood pressure and indoor temperature in winter was analyzed using a multilevel model with 3 levels: repeatedly measured day-level variables (eg, indoor ambient temperature and quality of sleep), nested within individual-level (eg, age and sex), and nested within household level. Cross-sectional analyses involving about 2900 participants (1840 households) showed that systolic blood pressure in the morning had significantly higher sensitivity to changes in indoor temperature (8.2 mm Hg increase/10°C decrease) than that in the evening (6.5 mm Hg increase/10°C decrease) in participants aged 57 years (mean age in this survey). We also found a nonlinear relationship between morning systolic blood pressure and indoor temperature, suggesting that the effect of indoor temperature on blood pressure varied depending on room temperature range. Interaction terms between age/women and indoor temperature were significant, indicating that systolic blood pressure in older residents and women was vulnerable to indoor temperature change. We expect that these results will be useful in determining optimum home temperature recommendations for men and women of each age group. Clinical Trial Registration—: URL: http://www.umin.ac.jp/ctr/index.htm . Unique identifier: UMIN000030601.
The coronavirus disease 2019 (COVID-19) pandemic has drastically changed work styles and environments. Given the coexistence of work in the office and work from home (WFH) in the future, studies are needed to identify ways to increase productivity when working in both places. We conducted a questionnaire survey and environment measurements of 916 workers in 22 offices across 2 weeks in November–December 2020 in Japan. While average workdays at the offices decreased from 4.9 to 3.9 days/week, those at homes increased from 0.1 to 1.1 days/week due to COVID-19, indicating an increase in the relative importance of WFH. Compared to the office, the satisfaction rate was lower for lighting, spatial, and information technology (IT) environments, but higher for thermal, air, and sound environments at home. Although it was easier to concentrate on work and to refresh at home, workers experienced challenges associated with business communication from home. Meanwhile, in the office, satisfaction with COVID-19 countermeasures was significantly associated with work productivity. Furthermore, lower PM2.5 concentration was associated with greater satisfaction with COVID-19 countermeasures, indicating that reducing PM2.5 may increase satisfaction with COVID-19 countermeasures and work productivity. We expect these findings will help improve work productivity in the New Normal era.
The WHO Housing and health guidelines recommend a minimum indoor temperature of 18°C to prevent cold-related diseases. In Japan, indoor temperatures appear lower than in Euro-American countries because of low insulation standards and use of partial intermittent heating. This study investigated the actual status of indoor temperatures in Japan and the common characteristics of residents who live in cold homes. We conducted a nationwide real-world survey on indoor temperature for 2 weeks in winter. Cross-sectional analyses involving 2190 houses showed that average living room, changing room, and bedroom temperatures were 16.8°C, 13.0°C, and 12.8°C, respectively. Comparison of average living room temperature between prefectures revealed a maximum difference of 6.7°C (Hokkaido: 19.8°C, Kagawa: 13.1°C). Compared to the high-income group, the odds ratio for living room temperature falling below 18°C was 1.38 (95% CI: 1.04-1.84) and 2.07 (95% CI: 1.28-3.33) for the middle- and low-income groups. The odds ratio was 1.96 (95% CI: 1.19-3.22) for single-person households, compared to households living with housemates. Furthermore, lower room temperature was correlated with local heating device use and a larger amount of clothes. These results will be useful in the development of prevention strategies for residents who live in cold homes.
Home blood pressure (HBP) variability is an important factor for cardiovascular events. While several studies have examined the effects of individual attributes and lifestyle factors on reducing HBP variability, the effects of living environment remain unknown. We hypothesized that a stable home thermal environment contributes to reducing HBP variability. We conducted an epidemiological survey on HBP and indoor temperature in 3785 participants (2162 households) planning to have their houses retrofitted with insulation. HBP was measured twice in the morning and evening for 2 weeks in winter. Indoor temperature was recorded with each HBP observation. We calculated the morning-evening (ME) difference as an index of diurnal variability and the standard deviation (SD), coefficient of variation (CV), average real variability (ARV) and variability independent of the mean (VIM) as indices of day-by-day variability. The association between BP variability and temperature instability was analyzed using multiple linear regression models. The mean ME difference in indoor/outdoor temperature (a decrease in temperature overnight) was 3.2/1.5 °C, and the mean SD of indoor/outdoor temperature was 1.6/2.5 °C. Linear regression analyses showed that the ME difference in indoor temperature was closely correlated with the ME difference in systolic BP (0.85 mmHg/°C, p < 0.001). The SD of indoor temperature was also associated with the SD of systolic BP (0.61 mmHg/°C, p < 0.001). The CV, ARV, and VIM showed similar trends as the SD of BP. In contrast, outdoor temperature instability was not associated with either diurnal or day-by-day HBP variability. Therefore, residents should keep the indoor temperature stable to reduce BP variability.
Current countermeasures for preventing hypertension emphasize only improvements to lifestyle. Recently, improving life environment has attracted attention, in parallel with publication of the WHO Housing and health guidelines. We quantitatively evaluated the relationship between housing thermal environment and blood pressure (BP) in a real-world setting. We conducted a nationwide, prospective intervention study—the Smart Wellness Housing survey—in Japan, as a non-randomized controlled trial. The intervention was the retrofitting of thermal insulation in houses. Participant recruitment was done by construction companies in all 47 prefectures of Japan. Measurements of home BP and indoor temperature at 1.0 m above the floor in the living room, changing room, and bedroom were taken for 2 weeks before and after the intervention each winter (November–March) of FY 2014–2019. As of July 2022, over 2500 households and 5000 participants were registered in the database. We found that (1) about 90% of Japanese lived in cold homes (minimum indoor temperature <18 °C), (2) indoor temperature was non-linearly associated with home BP, (3) morning systolic BP (SBP) was more sensitive than evening SBP to changes in indoor temperature, (4) SBP was influenced by indoor temperature change particularly in older participants and women, (5) unstable indoor temperature was associated with large BP variability, and (6) insulation retrofitting intervention significantly reduced home BP, especially in hypertensive patients. We proposed that the BP reduction effect of the life-environment is comparable to that achievable by lifestyle.
Objective: The WHO's Housing and health guidelines (2018) listed ‘low indoor temperatures and insulation’ as one of five priority areas, and indicated insulation retrofitting to help mitigate the effect of low indoor temperatures on health. However, there is still not enough evidence for the effect of insulation retrofitting based on an objective index. Methods: We conducted a nonrandomized controlled trial comparing home blood pressure (HBP) between insulation retrofitting (942 households and 1578 participants) and noninsulation retrofitting groups (67 households and 107 participants). HBP and indoor temperature were measured for 2 weeks before and after the intervention in winter. To examine the influence of insulation retrofitting on HBP, we used multiple linear regression analysis. Results: The analyses showed that indoor temperature in the morning rose by 1.4°C after insulation retrofitting, despite a slight decrease in outdoor temperature by 0.2°C. Insulation retrofitting significantly reduced morning home SBP (HSBP) by 3.1 mmHg [95% confidence interval (95% CI): 1.5–4.6], morning home DBP (HDBP) by 2.1 mmHg (95% CI: 1.1–3.2), evening HSBP by 1.8 mmHg (95% CI: 0.2–3.4) and evening HDBP by 1.5 mmHg (95% CI: 0.4–2.6). In addition, there was a dose–response relationship between indoor temperature and HBP, indicating the effectiveness of a significant improvement in the indoor thermal environment. Furthermore, there was heterogeneity in the effect of insulation retrofitting on morning HSBP in hypertensive patients compared with normotensive occupants (–7.7 versus –2.2 mmHg, P for interaction = 0.043). Conclusion: Insulation retrofitting significantly reduced HBP and was more beneficial for reducing the morning HSBP of hypertensive patients.