Dominique Clesse

Mr. Dominique Clesse

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2015 in Remote Sensing
Verified
Journal Article
Open access
PDF file
OHOlivier Hagolle
Olivier Hagolle
SSSylvia Sylvander
Sylvia Sylvander
MHMireille Huc
Mireille Huc
MCMartin Claverie
Martin Claverie
DCDominique Clesse
Dominique Clesse
VPVincent Poulain
Vincent Poulain
This paper presents the SPOT-4 (Take 5) experiment, aimed at providing time series of optical images simulating the repetitivity, the resolution and the large swath of Sentinel-2 images. The aim was to help users set up and test their applications and methods, before Sentinel-2 mission data become available. In 2016, when both Sentinel-2 satellites are operational, and for at least fifteen years, users will have access to high resolution time series of images systematically acquired every five days, over the whole Earth land surfaces. Thanks to Sentinel-2’s high revisit frequency, a given surface should be observed without clouds at least once a month, except in the most cloudy periods and regions. In 2013, the Centre National d’Etudes Spatiales (CNES) lowered the orbit altitude of SPOT-4, to place it on a five-day repeat cycle orbit for a duration of five months. This experiment started on 31 January 2013 and lasted until 19 June 2013. SPOT-4 images were acquired every fifth day, over 45 sites scattered in nearly all continents and covering very diverse biomes for various applications. Two ortho-rectified products were delivered for each acquired image that was not fully cloudy, expressed either as top of atmosphere reflectance (Level 1C) or as surface reflectance (Level 2A). An extensive validation campaign was held to check the performances of these products with regard to the multi-temporal registration, the quality of cloud masks, the accuracy of aerosol optical thickness estimates and the quality of surface reflectances. Despite high a priori geo-location errors, it was possible to register the images with an accuracy better than 0.5 pixels in the large majority of cases. Despite the lack of a blue band on the SPOT-4 satellite, the cloud and shadow detection yielded good results, while the aerosol optical thickness was measured with a root mean square error better than 0.06. The surface reflectances after atmospheric correction were compared with in situ data and other satellite data showing little bias and the standard deviation of surface reflectance errors in the range (0.01–0.02). The Take 5 experiment is being repeated in 2015 with the SPOT-5 satellite with an enhanced resolution.

17 September 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FTFranck Thollard
Franck Thollard
DCDominique Clesse
Dominique Clesse
MDMarie-Pierre Doin
Marie-Pierre Doin
JDJoëlle Donadieu
Joëlle Donadieu
PDPhilippe Durand
Philippe Durand
BSBernard Specht
Bernard Specht
The purpose of the ForM@Ter LArge-scale multi-Temporal Sentinel-1 InterferoMetry service (FLATSIM) is the massive processing of Sentinel-1 data using multi-temporal interferometric synthetic aperture radar (InSAR) over large areas, i.e., greater than 250,000 km2. It provides the French ForM@ter scientific community with automatically processed products using a state of the art processing chain based on a small baseline subset approach, namely the New Small Baseline (NSBAS). The service results from a collaboration between the scientific team that develops and maintains the NSBAS processing chain and the French Spatial Agency (CNES) that mirrors the Sentinel-1 data. The proximity to Sentinel-1 data, the NSBAS workflow, and the specific optimizations to make NSBAS processing massively parallel for the CNES high performance computing infrastructure ensures the efficiency of the chain, especially in terms of input and output, which is the key for the success of such a service. The FLATSIM service is made of a production module, a delivery module and a user access module. Products include interferograms, surface line of sight velocity, phase delay time series and auxiliary data. Numerous quality indicators are provided for an in-depth analysis of the quality and limits of the results. The first national call in 2020 for region of interest ended up with 8 regions spread over the world with scientific interests, including seismology, tectonics, volcano-tectonics, and hydrological cycle. To illustrate the FLATSIM capabilities, an analysis is shown here on two processed regions, the Afar region in Ethiopa, and the eastern border of the Tibetan Plateau.