Yi-Chao Wu

Prof. Yi-Chao Wu

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2024 in Advanced Science
Verified
Journal Article
Open access
XHXin Hu
Xin Hu
GCGuanrong Chen
Guanrong Chen
YHYingchen Huang
Yingchen Huang
QCQiyang Cheng
Qiyang Cheng
JZJianyong Zhuo
Jianyong Zhuo
XXXiao Xu
Xiao Xu
Recent studies suggest that circular RNA (circRNA)‐mediated post‐translational modification of RNA‐binding proteins (RBP) plays a pivotal role in metastasis of hepatocellular carcinoma (HCC). However, the specific mechanism and potential clinical therapeutic significance remain vague. This study attempts to profile the regulatory networks of circRNA and RBP using a multi‐omics approach. Has_circ_0006646 (circ0006646) is an unreported circRNA in HCC and is associated with a poor prognosis. Silencing of circ0006646 significantly hinders metastasis in vivo. Mechanistically, circ0006646 prevents the interaction between nucleolin (NCL) and the E3 ligase tripartite motif‐containing 21 to reduce the proteasome‐mediated degradation of NCL via K48‐linked polyubiquitylation. Furthermore, the change of NCL expression is proven to affect the phosphorylation levels of multiple proteins and inhibit p53 translation. Moreover, patient‐derived tumor xenograft and lentivirus injection, which is conducted to simulate clinical treatment confirmed the potential therapeutic value. Overall, this study describes the integrated multi‐omics landscape of circRNA‐mediated NCL ubiquitination degradation in HCC metastasis and provides a novel therapeutic target.

27 November 2021 in International Journal of Machine Learning and Cybernetics
Verified
Journal Article
Closed access
PDF file
MCMing-Hung Chang
Ming-Hung Chang
YWYi-Chao Wu
Yi-Chao Wu

27 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CTChiu-Ching Tuan
Chiu-Ching Tuan
CLCHI-HENG LU
CHI-HENG LU
YWYi-Chao Wu
Yi-Chao Wu
WYWen-Ling Yeh
Wen-Ling Yeh
HKHsuan-Kai Kao
Hsuan-Kai Kao
HKHsuan-Kai Kao
Hsuan-Kai Kao
Cast fixation is a general clinical skill used for the treatment of fractures. However, it may cause many complications due to careless treatment procedures. Currently, swathing a cast for a patient can only be determined by a doctors’ experience; however, this cannot be determined by the value of pressure, temperature, or humidity with objective and reliable equipment. When swathing a cast for a patient, the end result is often too tight or too loose. Hence, in this paper we developed a sensor for detecting pressure, temperature, and humidity, respectively. This could provide reliable reference cast data to help physicians to understand the tightness of cast swathing and to adjust the tightness of cast swathing instantly to alleviate a patient’s complications caused by excessive pressure or overheating. In this paper, six pressure sensors and one temperature–humidity sensor are used to detect the pressure, temperature, and humidity in an arm swathed with a cast to confirm whether the tightness of the cast is fixing the fracture efficiently, while avoiding causing any damage by using excessive pressure. Currently, the variation in temperature and humidity can be detected by the inflammation of the wound, displaying secretions, and fever in the cast. Based on the experiments, the voltage and power conversion coefficients of the developed sensors could be compensated for by the nonlinear error of the sensor. The experimental results could be instantly displayed on a human interface, such as a smart mobile device. The average skin pressure in a swathed cast was 12.14 g and ranged from 5.0 g to 17.5 g. A few casts exceeded 37.50 g. The abnormal pressure of wrinkles produced during swathing a cast often ranged from 22.50 g to 38.75 g. This shows that cast wrinkles cause pressure on the skin. The pressure caused by cast wrinkles on bone protrusions ranged from 56.5 g to 84.4 g. Compared to other parts that lacked soft skin cushioning, the pressure of cast wrinkles that occurred in the ulna near the protrusion of the wrist bone increased averagely. The pressure error value was less than 2%, the temperature error was less than 1%, and the humidity error was less than 5%. Therefore, they were all in line with the specifications of commercially available products. The six pressure detection points and one temperature and humidity detection point in our newly designed system can accurately measure the pressure, temperature, and humidity inside the cast, and instantly display the corresponding information by mobile APP. Doctors receive reliable reference data and are instantly able to understand the tightness of the swathed cast and adjust it at any time to avoid complications caused by pressure or overheating due to excessive pressure.

13 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Chi-Huang HungChi-Huang Hung
Chi-Huang Hung
YFYong-Yi Fanjiang
Yong-Yi Fanjiang
YLYi-Shiun Lee
Yi-Shiun Lee
YWYi-Chao Wu
Yi-Chao Wu
Due to the recent COVID-19 pandemic, many people have faced in-home isolation, as every suspected patient must stay at home. The behavior of such isolated people needs to be monitored to ensure that they are staying at home. Using a camera is a very practical method. However, smart bracelets are more convenient when personal privacy is a concern or when the blood oxygen value or heart rate must be monitored. In this study, a low-cost indoor positioning system that uses a Bluetooth beacon, a smart bracelet, and an embedded system is proposed. In addition to monitoring whether a person living alone is active in a specific environment and tracking the heart rate or blood oxygen value under particular conditions, this system can also send early warning signals to specific observation units or relatives through instant messaging software.

21 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CTChiu-Ching Tuan
Chiu-Ching Tuan
YWYi-Chao Wu
Yi-Chao Wu
WYWen-Ling Yeh
Wen-Ling Yeh
CWChun-Chieh Wang
Chun-Chieh Wang
CLCHI-HENG LU
CHI-HENG LU
HKHsuan-Kai Kao
Hsuan-Kai Kao
In this study, we developed a range of motion sensing system (ROMSS) to simulate the function of the elbow joint, with errors less than 0.76 degrees and 0.87 degrees in static and dynamic verification by the swinging and angle recognition modules, respectively. In the simulation process, the ɣ correlation coefficient of the Pearson difference between the ROMSS and the universal goniometer was 0.90, the standard deviations of the general goniometer measurements were between ±2 degrees and ±2.6 degrees, and the standard deviations between the ROMSS measurements were between ±0.5 degrees and ±1.6 degrees. With the ROMSS, a cloud database was also established; the data measured by the sensor could be uploaded to the cloud database in real-time to provide timely patient information for healthcare professionals. We also developed a mobile app for smartphones to enable patients and healthcare providers to easily trace the data in real-time. Historical data sets with joint activity angles could be retrieved to observe the progress or effectiveness of disease recovery so the quality of care could be properly assessed and maintained.