James Drummond

Dr. James Drummond


Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2012 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
Zen MarianiZen Mariani
Zen Mariani
KSK Strong
K Strong
MWM Wolff
M Wolff
PRP Rowe
P Rowe
VWV Walden
V Walden
ILI A Lindenmaier
I A Lindenmaier
The Extended-range Atmospheric Emitted Radiance Interferometer (E-AERI) is a moderate resolution (1 cm−1) Fourier transform infrared spectrometer for measuring the absolute downwelling infrared spectral radiance from the atmosphere between 400 and 3000 cm−1. The extended spectral range of the instrument permits monitoring of the 400–550 cm−1 (20–25 μm) region, where most of the infrared surface cooling currently occurs in the dry air of the Arctic. Spectra from the E-AERI have the potential to provide information about radiative balance, trace gases, and cloud properties in the Canadian high Arctic. Calibration, performance evaluation, and certification of the E-AERI were performed at the University of Wisconsin Space Science and Engineering Centre from September to October 2008. The instrument was then installed at the Polar Environment Atmospheric Research Laboratory (PEARL) Ridge Lab (610 m altitude) at Eureka, Nunavut, in October 2008, where it acquired one year of data. Measurements are taken every seven minutes year-round, including polar night when the solar-viewing spectrometers at PEARL are not operated. A similar instrument, the University of Idaho's Polar AERI (P-AERI), was installed at the Zero-altitude PEARL Auxiliary Laboratory (0PAL), 15 km away from the PEARL Ridge Lab, from March 2006 to June 2009. During the period of overlap, these two instruments provided calibrated radiance measurements from two altitudes. A fast line-by-line radiative transfer model is used to simulate the downwelling radiance at both altitudes; the largest differences (simulation-measurement) occur in spectral regions strongly influenced by atmospheric temperature and/or water vapour. The two AERI instruments at close proximity but located at two different altitudes are well-suited for investigating cloud forcing. As an example, it is shown that a thin, low ice cloud resulted in a 6% increase in irradiance. The presence of clouds creates a large surface radiative forcing in the Arctic, particularly in the 750–1200 cm−1 region where the downwelling radiance is several times greater than clear-sky radiances, which is significantly larger than in other more humid regions.

14 June 2013 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
Zen MarianiZen Mariani
Zen Mariani
KSK. Strong
K. Strong
MPM. Palm
M. Palm
RLR. Lindenmaier
R. Lindenmaier
CAC. Adams
C. Adams
JDJames Drummond
James Drummond
The Extended-range Atmospheric Emitted Radiance Interferometer (E-AERI) was installed at the Polar Environment Atmospheric Research Laboratory (PEARL) at Eureka, Nunavut, Canada in October 2008. Spectra from the E-AERI provide information about the radiative balance and budgets of trace gases in the Canadian high Arctic. Measurements are taken every 7 min year-round, including polar night when the solar-viewing spectrometers at PEARL are not operated. This allows E-AERI measurements to fill the gap in the PEARL dataset during the four months of polar night. Measurements were taken year-round in 2008–2009 at the PEARL Ridge Lab, which is 610 m a.s.l. (above sea-level), and from 2011 onwards at the Zero-Altitude PEARL Auxiliary Lab (0PAL), which is at sea level 15 km from the Ridge Lab. Total columns of O3, CO, CH4, and N2O have been retrieved using a modified version of the SFIT2 retrieval algorithm adapted for emission spectra. This provides the first ground-based nighttime measurements of these species at Eureka. Changes in the total columns driven by photochemistry and dynamics are observed. Analyses of E-AERI retrievals indicate accurate spectral fits (root-mean-square residuals consistent with noise) and a 10–15% uncertainty in the total column, depending on the trace gas. O3 comparisons between the E-AERI and a Bruker IFS 125HR Fourier transform infrared (FTIR) spectrometer, three Brewer spectrophotometers, two UV-visible ground-based spectrometers, and a System D'Analyse par Observations Zenithales (SAOZ) at PEARL are made from 2008–2009 and for 2011. 125HR CO, CH4, and N2O columns are also compared with the E-AERI measurements. Mean relative differences between the E-AERI and the other spectrometers are 1–10% (14% is for the un-smoothed profiles), which are less than the E-AERI's total column uncertainties. The E-AERI O3 and CO measurements are well correlated with the other spectrometers (r > 0.92 with the 125HR). The 24 h diurnal cycle and 365-day seasonal cycle of CO are observed and their amplitudes are quantified by the E-AERI (6–12 and 46%, respectively). The seasonal variability of H2O has an impact on the retrievals, leading to larger uncertainties in the summer months. Despite increased water vapour at the lower-altitude site 0PAL, measurements at 0PAL are consistent with measurements at PEARL.

1 May 1991 in Canadian Journal of Physics
Verified
Journal Article
Closed access
JFJ. W. Forsman
J. W. Forsman
PSP. M. Sinclair
P. M. Sinclair
PDP. Duggan
P. Duggan
JDJames Drummond
James Drummond
AMA. D. May
A. D. May
The details and performance of a shot-noise-limited high-resolution (≤ 2 MHz) Raman gain spectrometer are discussed and compared to a "standard" continuous wave (cw) spectrometer. For a single pass cell and 1 s integration time, a signal-to-noise ratio greater than 1000 is obtained for the Q(2) line of D2 at pressures above a few atmospheres. The quality of the spectrometer for the determination of spectral profiles is demonstrated by examining the Dicke narrowing of the line.

26 October 2006 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
DDDenis G. Dufour
Denis G. Dufour
JDJames Drummond
James Drummond
CMC. Thomas McElroy
C. Thomas McElroy
CMClive Midwinter
Clive Midwinter
PBPeter F. Bernath
Peter F. Bernath
CNCaroline Nowlan
Caroline Nowlan

1 November 1997 in International Journal of Infrared and Millimeter Waves
Verified
Journal Article
Closed access
PDF file
APA. Predoi-Cross
A. Predoi-Cross
RLR. M. Lees
R. M. Lees
HLH. Lichau
H. Lichau
MWM. Winnewisser
M. Winnewisser
JDJames Drummond
James Drummond

14 May 2020 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Open access
CPChristopher Perro
Christopher Perro
TDThomas J. Duck
Thomas J. Duck
GLGlen Lesins
Glen Lesins
KSKimberly Strong
Kimberly Strong
JDJames Drummond
James Drummond
Wintertime Arctic surface emissivities are retrieved from Advanced Technology Microwave Sounder (ATMS) passive microwave measurements at 88.2, 165.5, and 183.31 GHz. Surface emitting layer temperatures are simultaneously retrieved at 183.31 GHz. Random errors in emissivities are estimated to be 2.0%, 2.0%, and 3.5% at 88.2, 165.5, and 183.31 GHz, respectively, and the random errors in surface emitting layer temperatures are 4.3 K. A series of tests on the retrieved products reveal that land and sea ice are Lambertian reflectors and ocean is a specular reflector. The retrieved emissivities show broad agreement with products from published databases, with differences partly due to the uncertainties in surface emitting layer temperatures. The geographical distribution of 165.5/183.31 GHz surface reflectance ratios over land and sea ice, which is important for the retrieval of microwave satellite water vapor column (WVC), is presented. Neglecting the geographical variations leads to random errors in retrieved wintertime Arctic WVCs of approximately 1.8% and 25% in the mid (1.5-9 kgm⁻²) and extended (8-15 kgm⁻²) slant column retrieval regimes, respectively. Choosing specular instead of Lambertian reflection in the surface emissivity retrievals over land and sea ice causes systematic WVC retrieval errors of up to -4.1%.