Alejandro Abarca-Blanco

Alejandro Abarca-Blanco


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
EGEverardo González-González
Everardo González-González
RGRicardo Garcia-Ramirez
Ricardo Garcia-Ramirez
GDGladys Guadalupe Díaz-Armas
Gladys Guadalupe Díaz-Armas
MEMiguel Esparza
Miguel Esparza
Carlos Aguilar-AvelarCarlos Aguilar-Avelar
Carlos Aguilar-Avelar
ALand Juan F. Yee-de León
and Juan F. Yee-de León
The COVID-19 pandemic has been the most critical public health issue in modern history due to its highly infectious and deathly potential, and the limited access to massive, low-cost, and reliable testing has significantly worsened the crisis. The recovery and the vaccination of millions of people against COVID-19 have made serological tests highly relevant to identify the presence and levels of SARS-CoV-2 antibodies. Due to its advantages, microfluidic-based technologies represent an attractive alternative to the conventional testing methodologies used for these purposes. In this work, we described the development of an automated ELISA on-chip capable of detecting anti-SARS-CoV-2 antibodies in serum samples from COVID-19 patients and vaccinated individuals. The colorimetric reactions were analyzed with a microplate reader. No statistically significant differences were observed when comparing the results of our automated ELISA on-chip against the ones obtained from a traditional ELISA on a microplate. Moreover, we demonstrated that it is possible to carry out the analysis of the colorimetric reaction by performing basic image analysis of photos taken with a smartphone, which constitutes a useful alternative when lacking specialized equipment or a laboratory setting. Our automated ELISA on-chip has the potential to be used in a clinical setting and mitigates some of the burden caused by testing deficiencies.

24 September 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CACarlos Aguilar-Avelar
Carlos Aguilar-Avelar
BSBrenda Soto-García
Brenda Soto-García
DADiana Aráiz-Hernández
Diana Aráiz-Hernández
JLJuan F. Yee-De León
Juan F. Yee-De León
MEMiguel Esparza
Miguel Esparza
JWJ. D. Wong-Campos
J. D. Wong-Campos
Circulating tumor cells (CTCs) have the potential of becoming the gold standard marker for cancer diagnosis, prognosis and monitoring. However, current methods for its isolation and characterization suffer from equipment variability and human operator error that hinder its widespread use. Here we report the design and construction of a fully automated high-throughput fluorescence microscope that enables the imaging and classification of cancer cells that were labeled by immunostaining procedures. An excellent agreement between our machine vision-based approach and a state-of-the-art microscopy equipment was achieved. Our integral approach provides a path for operator-free and robust analysis of cancer cells as a standard clinical practice.

5 May 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JLJuan F. Yee-De León
Juan F. Yee-De León
BSBrenda Soto-García
Brenda Soto-García
DADiana Aráiz-Hernández
Diana Aráiz-Hernández
JDJesus Rolando Delgado-Balderas
Jesus Rolando Delgado-Balderas
MEMiguel Esparza
Miguel Esparza
AAAlejandro Abarca-Blanco
Alejandro Abarca-Blanco
The detection and analysis of circulating tumor cells (CTCs) may enable a broad range of cancer-related applications, including the identification of acquired drug resistance during treatments. However, the non-scalable fabrication, prolonged sample processing times, and the lack of automation, associated with most of the technologies developed to isolate these rare cells, have impeded their transition into the clinical practice. This work describes a novel membrane-based microfiltration device comprised of a fully automated sample processing unit and a machine-vision-enabled imaging system that allows the efficient isolation and rapid analysis of CTCs from blood. The device performance was characterized using four prostate cancer cell lines, including PC-3, VCaP, DU-145, and LNCaP, obtaining high assay reproducibility and capture efficiencies greater than 93% after processing 7.5 mL blood samples spiked with 100 cancer cells. Cancer cells remained viable after filtration due to the minimal shear stress exerted over cells during the procedure, while the identification of cancer cells by immunostaining was not affected by the number of non-specific events captured on the membrane. We were also able to identify the androgen receptor (AR) point mutation T878A from 7.5 mL blood samples spiked with 50 LNCaP cells using RT-PCR and Sanger sequencing. Finally, CTCs were detected in 8 out of 8 samples from patients diagnosed with metastatic prostate cancer (mean ± SEM = 21 ± 2.957 CTCs/mL, median = 21 CTCs/mL), demonstrating the potential clinical utility of this device.

8 August 2021 in medRxiv
Verified
Preprint
Open access
PDF file
EGEverardo González-González
Everardo González-González
RGRicardo Garcia-Ramirez
Ricardo Garcia-Ramirez
GDGladys Guadalupe Díaz-Armas
Gladys Guadalupe Díaz-Armas
MEMiguel Esparza
Miguel Esparza
CACarlos Aguilar-Avelar
Carlos Aguilar-Avelar
ALand Juan F. Yee-de León
and Juan F. Yee-de León
The COVID-19 pandemic has been the most critical public health issue in modern his-tory due to its highly infectious and deathly potential; and the limited access to massive, low-cost, and reliable testing has significantly worsened the crisis. The recovery and the vaccination of millions of people against COVID-19, have made serological tests highly relevant to identify the presence and levels of SARS-CoV-2 antibodies. Due to its advantages, microfluidic-based technologies represent an attractive alternative to the conventional testing methodologies used for these purposes. In this work, we describe the development of an automated ELISA on-chip capable of detecting anti-SARS-CoV-2 antibodies in serum samples from COVID-19 patients and vaccinated individuals. The colorimetric reactions were analyzed with a microplate reader. No statistically significant differences were observed when comparing the results of our automated ELISA on-chip against the ones obtained from a traditional ELISA on a microplate. Moreover, we demonstrated that it is possible to carry out the analysis of the colorimetric reaction by performing basic image analysis of photos taken with a smartphone, which constitutes a useful alternative when lacking specialized equipment or a laboratory setting. Our automated ELISA on-chip has the potential to be used in a clinical setting and mitigate some of the burden caused by testing deficiencies.

11 December 2019 in arXiv
Verified
Preprint
Open access
PDF file
JLJuan F. Yee-De León
Juan F. Yee-De León
BSBrenda Soto-García
Brenda Soto-García
DADiana Aráiz-Hernández
Diana Aráiz-Hernández
JDJesús Rolando Delgado-Balderas
Jesús Rolando Delgado-Balderas
MEMiguel A. Esparza
Miguel A. Esparza
AAAlejandro Abarca-Blanco
Alejandro Abarca-Blanco
The detection and analysis of circulating tumor cells (CTCs) may enable a broad range of cancer-related applications, including the identification of acquired drug resistance during treatments. However, the non-scalable fabrication, prolonged sample processing times, and the lack of automation, associated with most of the technologies developed to isolate these rare cells, have impeded their transition into the clinical practice. This work describes a novel membrane-based microfiltration device comprised of a fully automated sample processing unit and a machine-vision-enabled imaging system that allows the efficient isolation and rapid analysis of CTCs from blood. The device performance was characterized using four prostate cancer cell lines, including PC-3, VCaP, DU-145, and LNCaP, obtaining high assay reproducibility and capture efficiencies greater than 93% after processing 7.5 mL blood samples from healthy donors, spiked with 100 cancer cells. Cancer cells remained viable after filtration due to the minimal shear stress exerted over cells during the procedure, while the identification of cancer cells by immunostaining was not affected by the number of non-specific events captured on the membrane. We were also able to identify the androgen receptor (AR) point mutation T878A from 7.5 mL blood samples spiked with 50 LNCaP cells using RT-PCR and Sanger sequencing. Finally, CTCs were detected in 8 of 8 samples from patients diagnosed with metastatic prostate cancer (mean $\pm$ SEM = 21 $\pm$ 2.957 CTCs/mL, median = 21 CTC/mL), thereby validating the potential clinical utility of the device.