Abeer Hassan

Dr. Abeer Hassan


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2022 in Discover Nano
Verified
Journal Article
Open access
PDF file
HEHanady Elgamal
Hanady Elgamal
SMSamah Abdelsabour Mohamed
Samah Abdelsabour Mohamed
AFA.A. Farghali
A.A. Farghali
AHAbeer Hassan
Abeer Hassan
In this work, the preparation of a PEG@ multi-walled carbon nanotubes (MWCNTs) composite has shown a great potential effect in tumor therapy using graphite powder at room temperature. PEGylated MWCNTs were created and used as a carrier for targeting the antineoplastic drug Ixazomib to myeloma cancer cells (abnormal plasma cells). Ixazomib (MLN2238) was covalently encapsulated into functionalized carbon nanotubes modified with polyethylene glycol (PEG 600) to obtain MWCNTs-PEG-MLN2238. The Ixazomib@ MWCNTs-PEG composite shows promising results as an effective nanocarrier and using a small amount of MWCNTs-PEG-Ixazomib that has a low toxicity compared with that of Ixazomib alone. A multifunctional MWCNTs-PEG-Ixazomib composite is used to test biological effects on multiple myeloma cell lines RPMI 8226 using the MTT assay to enhance treatment efficiency. The cytotoxicity of free Ixazomib citrate (69% cell viability of RPMI8226 cells) was higher than that of MWCNTs-PEG-Ixazomib (91% cell viability) at the same maximum concentration of Ixazomib citrate (50 µg/ml). In this work, we performed a study of preparation of MWCNTs with an acceptable Ixazomib loading efficiency and determination of the drug systemic toxicity for the first time. In this study, the preparation of MWCNTs with acceptable Ixazomib loading efficiency and determination of the drug systemic toxicity was performed for the first time. The MTT assay results show decreasing the toxicity of Ixazomib after loading with the MWCNTs-PEG composite. The MWCNTs-PEG @ Ixazomib show promising results as an effective carrier of Ixazomib and lead to a decrease in the cost of using Ixazomib. Graphical Abstract

24 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AHAbeer Hassan
Abeer Hassan
MHMohamed A. El HAmd
Mohamed A. El HAmd
Mahmoud El-MaghrabeyMahmoud El-Maghrabey
Mahmoud El-Maghrabey
WMWael Ali Mahdi
Wael Ali Mahdi
SASultan Alshehri
Sultan Alshehri
HBHany El batakoushy
Hany El batakoushy
Herein, we developed a new pencil graphite ion-selective electrode strategy for the broadly used erectile dysfunction medication, sildenafil citrate (SC, vitamin V), for its automated potentiometry and potentiometric titration profiling in marketed tablets and human urine samples. The method was based on ion-pair complexation between SC and sodium tetraphenylborate (Na-TPB) or phosphotungstic acid (PTA), embedded into a pencil-fabricated graphite sensor electrode coated with poly(vinyl chloride, PVC) matrix, which is pre-plasticized with two different pre-studied plasticizers. The modern fabricated electrodes have a proven fast near-Nernstian response for SC over the concentration range of 1.0 × 10−6 to 1.0 × 10−2 and 1.0 × 10−5 to 1.0 × 10−2 M, with LODs of 6.5 × 10−7 and 5.5 × 10−6 over a pH 3–6 for (SC-TPB)- and (SC-PTA)-based membrane sensors, of O-nitrophenyl octyl ether (O-NPOE) and dioctyl phthalate (DOP), respectively. The selectivity coefficients for different interferents, including many inorganic cations, sugars, and/or nitrogenous compounds, were tested and confirmed. Applications of the proposed method were conducted on the determination of SC in its tablets and urine samples under the proper conditions. The percent recovery values were compared with those obtained by an official method and showed an RSD ≤ 0.3% (n = 5).