Michaela Matuskova

Dr. Michaela Matuskova

Comenius University in Bratislava
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JPJuraj Piestansky
Juraj Piestansky
Michaela MatuskovaMichaela Matuskova
Michaela Matuskova
ICIvana Cizmarova
Ivana Cizmarova
DODominika Olešová
Dominika Olešová
Peter MikušPeter Mikuš
Peter Mikuš
In the presented study, a capillary electrophoresis-mass spectrometry method combining high separation efficiency and sensitive detection has been developed and validated, for the first time, to quantify branched chain amino acids (valine, isoleucine, leucine) in commercial food and sport supplement samples and human plasma samples. The separations were performed in a bare fused silica capillary. The background electrolyte was composed of 500 mM formic acid with pH 2.0. The plasma sample pretreatment was realized by simple protein precipitation with acetonitrile. Injection of a short zone of highly basic electrolyte before the sample injection and application of the negative pressure on the separation were accompanied by enhanced resolution of the isobaric amino acids—isoleucine and leucine. The developed method was characterized by favorable validation parameters, such as linearity (r2 > 0.99), accuracy and precision, the limit of detection, lower limit of quantification, or robustness. These parameters were more than sufficient for the quantification of branched chain amino acids in various samples. The determined concentrations of branched chain amino acids in food and sports supplements were in very good agreement with the content declared by the manufacturer. The investigated concentrations of branched chain amino acids were in the range 294.68–359.24 µM for valine, 91.76–95.67 µM for isoleucine, and 196.78–251.24 µM for leucine. These concentrations fall within the physiological limits. The developed CE-MS/MS method represents a suitable alternative to traditional approaches used in branched chain amino acid quality control and bioanalysis.

16 October 2021 in Biomedicines
Verified
Journal Article
Open access
PDF file
JPJuraj Piestansky
Juraj Piestansky
IČIvana Čižmárová
Ivana Čižmárová
OŠOndrej Štefánik
Ondrej Štefánik
Michaela MatuskovaMichaela Matuskova
Michaela Matuskova
AHAndrea Horniaková
Andrea Horniaková
Peter MikušPeter Mikuš
Peter Mikuš
A capillary electrophoresis–tandem mass spectrometry method with a multisegment injection and an in-capillary field-enhanced sample stacking for determination of therapeutic peptide triptorelin in pharmaceutical and biological matrices was developed. The CE separation conditions were optimized in order to obtain maximal separation efficiency, analytical signal intensity and stability, and minimal adsorption of the analyzed peptide onto the capillary wall (1 M formic acid—HFo, pH 1.88). The implementation of the field-enhanced sample injection into CE improved the value of limit of detection 50 times while the multisegment injection increased the sample throughput three times in comparison to a conventional CE approach. The proposed method was characterized by favorable performance parameters, such as linearity (r2 ≥ 0.99), limit of detection (5 ng mL−1 in water matrix, 25 ng mL−1 in plasma matrix), precision (relative standard deviation, 1.5–9.4% for intraday and 2.3–11.9% for interday reproducibility), or accuracy (relative errors in the range of 80–109%). The FDA-validated method was successfully applied to the analysis of triptorelin in the commercial drug Diphereline® 0.1 mg (powder for injection) and in spiked human plasma samples. Favorable performance parameters along with proven application potentialities indicate the usefulness of the proposed method for its routine use in drug quality control laboratories and for clinical analysis, such as determination of triptorelin levels in plasma (for pharmacokinetic study).

11 May 2022 in Separations
Verified
Journal Article
Open access
PDF file
OSOndrej Stefanik
Ondrej Stefanik
AHAndrea Horniakova
Andrea Horniakova
IČIvana Čižmárová
Ivana Čižmárová
Michaela MatuskovaMichaela Matuskova
Michaela Matuskova
VMVeronika Mikušová
Veronika Mikušová
JPJuraj Piestansky
Juraj Piestansky
A simple analytical approach based on capillary zone electrophoresis with ultraviolet detection and repeated sample injection strategy (applied in a hydrodynamically closed separation system for the first time) was developed for the determination of ibuprofen (IBU) in commercially available pharmaceutical preparations. The proposed method was characterized by significantly increased sample throughput and favorable validation parameters, highly demanded in routine quality control laboratories. The limit of detection was predicted at the concentration level of 0.31 µg/mL. Intra-day precision expressed as the relative standard deviation of IBU concentration ranged from 1.9 to 5.6%, and corresponding intra-day accuracy expressed as the relative error was in the interval of 87.1–106.5%. Inter-day precision was in the range of 2.6–15.0%, and inter-day accuracy was 94.9–102.7%. The developed method was able to quantify IBU in complex pharmaceutical matrices represented by commercially available tablets and oral suspension. The determined contents of IBU in the tested dosage forms were in good agreement with the manufacturer’s declaration. The analytical performance of the developed method was evaluated according to the innovative RGB Additive Color Model strategy. It was demonstrated that the proposed method is characterized by very good analytical performance parameters, safety and eco-friendliness, and practical effectiveness.

1 January 2021 in European Pharmaceutical Journal
Verified
Journal Article
Open access
PDF file
Michaela MatuskovaMichaela Matuskova
Michaela Matuskova
ICI. Cizmarova
I. Cizmarova
PCP. Chalova
P. Chalova
PMP. Mikus
P. Mikus
JPJuraj Piestansky
Juraj Piestansky
The application of hydrodynamically closed capillary zone electrophoresis combined with convenient ultraviolet (UV) detection allows fast, simple, environmentally friendly and cost-effective analysis of ions or ionisable molecules. This technique has been used to determine two selected B vitamins (thiamine, pyridoxine) in various drug formulations. The developed method was characterised by excellent validation parameters, such as linearity, precision, accuracy, limit of detection and limit of quantification. The total time of analysis was lower than 13.5 min. The results indicate that the method is suitable for implementation in routine quality control of selected B vitamins in pharmaceutical and food samples.

1 January 2022 in European Pharmaceutical Journal
Verified
Journal Article
Open access
PDF file
Michaela MatuskovaMichaela Matuskova
Michaela Matuskova
ICI. Cizmarova
I. Cizmarova
PCP. Chalova
P. Chalova
OSO. Stefanik
O. Stefanik
AHA. Horniakova
A. Horniakova
JPJuraj Piestansky
Juraj Piestansky
The effects of organic modifiers—alcohols (methanol, isopropanol), acetonitrile, and tetrahydrofuran—and β-cyclodextrins in capillary zone electrophoresis were investigated using a test mixture containing five biogenic amines important from the human health point of view—serotonin, dopamine, adrenaline, noradrenaline, and tyramine—and two B vitamins—thiamine and pyridoxine. The simultaneous addition of tetrahydrofuran and isopropanol was found to improve the resolution of determined analytes and enable effective separation of analytes with very similar electromigration characteristics migrating as one peak (dopamine and serotonin). The developed and optimised separation method based on capillary zone electrophoresis and ultraviolet detection was capable to achieve detection limits at the concentration level in the range of 0.15 to 1.25 μg/mL −1 . The developed method was also characterised by other favourable validation parameters, such as linearity ( r 2 > 0.99), accuracy (82.9–117.8% for the intraday measurements, and 87.6–119.2% for the interday measurements), and precision (intraday relative standard deviation in the range of 0.4–15.5%, interday relative standard deviation in the range of 0.9–18.3%). The method was finally applied to investigate the stability of the analytes in model water matrix samples under various storage conditions.