Purpose. To determine the feasibility of performing intraocular surgeries in a heads-up position with low illuminance conditions by observing a display of the surgical field created by a three-dimensional imaging (3D) system. Methods. Seventy-four eyes of 56 patients underwent cataract surgery (72 eyes) with the heads-up 3D surgery system; 60 eyes with cataract surgery alone, 7 eyes with combined cataract and glaucoma microdevice implant surgery, 5 eyes with combined cataract and vitrectomy surgery, and two eyes with vitrectomy surgery alone were studied. The illuminance from the surgical microscope was set to be dimmer (Leica M822F40 main light 2%; otto-flex 6%) than the usual setting to minimize the discomfort and glare for the patient. The surgeries were performed under topical anesthesia. The luminance of the images observed through the eyepieces of the operating microscope and the image of a 3D system created by a high-sensitivity sensor Exmor R 3CMOS HD camera (Sony MCC-1000MD) were measured. Results. All surgeries were completed without any complications under the low illumination conditions. The surgical field on the display monitor was created by a 3D system using a high-sensitivity sensor camera and was observed in a heads-up position. The patients did not report any intolerable discomfort or glare during the surgery. Cataract surgeries were performed with a good view of the surgical field under the extremely low illumination from the surgical microscope. The high-sensitivity sensors and electronic amplifications of the image signals made the surgical field brighter and allowed the surgeon to perform the surgery confidently and safely. Conclusions. Heads-up, 3D-assisted intraocular surgeries can be performed safely and efficiently with low illuminance of the surgical field. This trial is registered with UMIN000037838.
Purpose: Acute zonal occult outer retinopathy (AZOOR) is characterized by an acute zonal loss of outer retinal function with minimal ophthalmoscopic changes in one or both eyes. We present a patient with AZOOR whose ultrastructural and functional findings were followed for 8 months. Case: A 22-year-old woman developed an acute central scotoma in her right eye. Her best-corrected visual acuity (BCVA) was 0.5 OD and 1.2 OS. The ophthalmoscopic examinations, fluorescein angiography, and full-field electroretinograms (ERGs) were normal in both eyes. The amplitudes of the multifocal ERGs (mfERGs) were attenuated in the area corresponding to the scotoma. Spectral domain optical coherence tomography showed an absence of both the inner and outer segment (IS/OS) line of the photoreceptors and the cone outer segment tip (COST) line between the IS/OS line and the retinal pigment epithelium. These changes were seen in the area corresponding to the scotoma. One month later, the scotoma disappeared and the BCVA improved to 1.2 OD. The mfERGs increased to almost the same amplitude as the fellow eye. The IS/OS line became discernible but the COST line was still absent. The ophthalmological findings of the right macula remained normal during the 11-month follow-up period. Conclusions: Our findings indicate that the selective loss of the IS/OS and the COST lines is probably the morphological alterations corresponding with the reduced BCVA and the mfERGs in the areas of the visual field defects in the acute phase of AZOOR. But in the recovery phase, only the abnormality of the COST line is a subclinical sign for the disease. These findings should be important in understanding and evaluating the pathological mechanism in other outer retinal diseases.
The temperature of the vitreous has been reported to vary during cataract and vitreous surgery. We measured intraocular temperature at four intraocular sites; the anterior chamber (AC), just behind the crystalline lens, mid-vitreous, and just anterior to the optic disc (OD) at the beginning of vitrectomy with a thermoprobe in 48 eyes. The temperatures were compared in three groups; eyes that underwent vitrectomy for the first time (Group V, n = 30), eyes that had previous vitrectomy and the vitreous cavity had been filled with balanced salt solution (BSS; Group A, n = 12), and eyes that had previous vitrectomy and the vitreous cavity was filled with silicone oil (Group S, n = 6). There was a gradient in the temperature in all groups, i.e., it was lowest in the AC, and it increased at points closer to the retina. The intraocular temperature was significantly correlated with the type of fluid in the vitreous cavity. The mean intraocular temperatures were not significantly different in Groups V and A, but they were significantly higher in Group S. Clinicians should be aware of the differences in the temperature at the different intraocular sites because the temperatures may affect the physiology of the retina and the recovery process.
1 September 2009 in Japanese Journal of Ophthalmology