We present and compare six simulation codes for positive streamer discharges from six different research groups. Four groups use a fully self-implemented code and two make use of COMSOL Multiphysics ® . Three test cases are considered, in which axisymmetric positive streamers are simulated in dry air at 1 bar and 300 K in an undervolted gap. All groups use the same fluid model with the same transport coefficients. The first test case includes a relatively high background density of electrons and ions without photoionization. When each group uses their standard grid resolution, results show considerable variation, particularly in the prediction of streamer velocities and maximal electric fields. However, for sufficiently fine grids good agreement is reached between several codes. The second test includes a lower background ionization density, and oscillations in the streamer properties, branching and numerical instabilities are observed. By using a finer grid spacing some groups were able to reach reasonable agreement in their results, without oscillations. The third test case includes photoionization, using both Luque’s and Bourdon’s Helmholtz approximation. The results agree reasonably well, and the numerical differences appear to be more significant than the type of Helmholtz approximation. Computing times, used hardware and numerical parameters are described for each code and test case. We provide detailed output in the supplementary data, so that other streamer codes can be compared to the results presented here.
25 February 2013 in Fundamental & Clinical Pharmacology
Two plasma devices at atmospheric pressure (air dielectric barrier discharge and helium plasma jet) have been used to study the early germination of Arabidopsis thaliana seeds during the first days. Then, plasma activated waters are used during the later stage of plant development and growth until 42 days. The effects on both testa and endospserm ruptures during the germination stage are significant in the case of air plasma due to its higher energy and efficiency of producing reactive oxygen species than the case of helium plasma. The latter has shown distinct effects only for testa rupture. Analysis of germination stimulations are based on specific stainings for reactive oxygen species production, peroxidase activity and also membrane permeability tests. Furthermore, scanning electron microscopy (SEM) has shown a smoother seed surface for air plasma treated seeds that can explain the plasma induced-germination. During the growth stage, plants were watered using 4 kinds of water (tap and deionized waters activated or not by the low temperature plasma jet). With regards to other water kinds, the characterization of the tap water has shown a larger conductivity, acidity and concentration of reactive nitrogen and oxygen species. Only the tap water activated by the plasma jet has shown a significant effect on the plant growth. This effect could be correlated to reactive nitrogen species such as nitrite/nitrate species present in plasma activated tap water.
In order to investigate the effects of low temperature plasmas on germination of Arabidopsis thaliana seeds, a dielectric barrier discharge device generating the plasma in ambient air was used. To highlight the different plasma effects on the seed surface, saline and osmotic stresses were considered in the case of reference Col-0 seeds and two further seed coat mutants gl2 and gpat5 to better analyse the seed surface changes and their consequences on germination. The GL2 gene encode a transcription factor controlling the balance between the biosynthesis of fatty acids in the embryo and the production of mucilage and flavonoid pigments in the seed coat. The GPAT5 gene encode for an acyltransferase necessary for the accumulation of suberin in the seed coat which is essential for the embryo protection. The testa and endosperm ruptures are identified to note the germination stage. An increasing of germination rate, possibly due to the modification of mantle layers structure, is observed in most of cases, even in presence of saline or osmotic stress, after plasma treatment. Furthermore, we demonstrated that the germination rate of the gl2 mutant seeds is increased by at most 47% after plasma treatment, contrariwise, the germination of gpat5 mutant being initially lower is inhibited by the same plasma treatment. The scanning electron microscopy pictures and confocal microscopy fluorescence both showed changes of the exterior aspects of the seeds after plasma treatment. Considering these results, we assumed that lipid compounds can be found on the surface. To validate this hypothesis, permeability tests were performed, and it was clearly shown that a permeability decrease is induced by the low temperature plasma treatment.
8 November 2011 in Plasma Sources Science and Technology
This work is devoted to the characterization of type I collagen treated by a low-temperature plasma jet generated in ambient air to determine whether the resulting fibrous material is structurally preserved or reinforced. The physical structure of collagen is checked by differential scanning calorimetry (DSC), which is a well suited technique to analyze thermal transitions in proteins, such as denaturation. DSC is used to evaluate the thermal stability of collagen after the plasma treatments while Fourier transform infra red spectroscopy is used to check the integrity of triple helical domain and to investigate the effects of plasma treatments on the functional groups of collagen. It is more particularly shown that the plasma treatment can stabilize the collagen structure without altering the triple helical structure. This observation is supported by 1) the shift observed toward high-temperature range of the collagen denaturation and 2) the stiffening of the chains by a cross-linking action when compared to the control sample.