Henrike Mueller-Werkmeister

Prof. Dr. Henrike Mueller-Werkmeister


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2019 in Science
Verified
Journal Article
Closed access
PDF file
PMPedram Mehrabi
Pedram Mehrabi
ESEike C. Schulz
Eike C. Schulz
RDRaison Dsouza
Raison Dsouza
HMHenrike Mueller-Werkmeister
Henrike Mueller-Werkmeister
FTFriedjof Tellkamp
Friedjof Tellkamp
Emil F. PaiEmil F. Pai
Emil F. Pai
Active sites that move together: Enzymes often form dimers or higher-order oligomers, even when each active site is isolated and the reactions are simple. But the effect of a neighbor can be profound. Mehrabi et al. used a photolabile compound to initiate a reaction in the enzyme fluoroacetate dehalogenase, which they could follow by time-resolved serial synchrotron crystallography. Snapshots of the reaction revealed coupled allosteric motions between the two active sites of the dimeric enzyme. Each active site traded the ability to bind substrate and catalyze the reaction, such that only one was engaged at a time. This behavior is common in enzymes but is rarely visualized and still poorly understood. Science , this issue p. 1167

31 March 2017 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
RORobin L. Owen
Robin L. Owen
DADanny Axford
Danny Axford
DSDarren A. Sherrell
Darren A. Sherrell
AKAnling Kuo
Anling Kuo
OEOliver P. Ernst
Oliver P. Ernst
HMHenrike Mueller-Werkmeister
Henrike Mueller-Werkmeister
The development of serial crystallography has been driven by the sample requirements imposed by X-ray free-electron lasers. Serial techniques are now being exploited at synchrotrons. Using a fixed-target approach to high-throughput serial sampling, it is demonstrated that high-quality data can be collected from myoglobin crystals, allowing room-temperature, low-dose structure determination. The combination of fixed-target arrays and a fast, accurate translation system allows high-throughput serial data collection at high hit rates and with low sample consumption.

1 February 2019 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
IMIsabelle Martiel
Isabelle Martiel
HMHenrike Mueller-Werkmeister
Henrike Mueller-Werkmeister
ACAina E. Cohen
Aina E. Cohen
Highly efficient data-collection methods are required for successful macromolecular crystallography (MX) experiments at X-ray free-electron lasers (XFELs). XFEL beamtime is scarce, and the high peak brightness of each XFEL pulse destroys the exposed crystal volume. It is therefore necessary to combine diffraction images from a large number of crystals (hundreds to hundreds of thousands) to obtain a final data set, bringing about sample-refreshment challenges that have previously been unknown to the MX synchrotron community. In view of this experimental complexity, a number of sample delivery methods have emerged, each with specific requirements, drawbacks and advantages. To provide useful selection criteria for future experiments, this review summarizes the currently available sample delivery methods, emphasising the basic principles and the specific sample requirements. Two main approaches to sample delivery are first covered: (i) injector methods with liquid or viscous media and (ii) fixed-target methods using large crystals or using microcrystals inside multi-crystal holders or chips. Additionally, hybrid methods such as acoustic droplet ejection and crystal extraction are covered, which combine the advantages of both fixed-target and injector approaches.

1 August 2014 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
LWLuuk J. G. W. van Wilderen
Luuk J. G. W. van Wilderen
DKDaniela Kern-Michler
Daniela Kern-Michler
HMHenrike Mueller-Werkmeister
Henrike Mueller-Werkmeister
JBJens Bredenbeck
Jens Bredenbeck
We investigated the characteristics of the thiocyanate (SCN) functional group as a probe of local structural dynamics for 2D-IR spectroscopy of proteins, exploiting the dependence of vibrational frequency on the environment of the label. Steady-state and time-resolved infrared spectroscopy are performed on the model compound methylthiocyanate (MeSCN) in solvents of different polarity, and compared to data obtained on SCN as a local probe introduced as cyanylated cysteine in the protein bovine hemoglobin. The vibrational lifetime of the protein label is determined to be 37 ps, and its anharmonicity is observed to be lower than that of the model compound (which itself exhibits solvent-independent anharmonicity). The vibrational lifetime of MeSCN generally correlates with the solvent polarity, i.e. longer lifetimes in less polar solvents, with the longest lifetime being 158 ps. However, the capacity of the solvent to form hydrogen bonds complicates this simplified picture. The long lifetime of the SCN vibration is in contrast to commonly used azide labels or isotopically-labeled amide I and better suited to monitor structural rearrangements by 2D-IR spectroscopy. We present time-dependent 2D-IR data on the labeled protein which reveal an initially inhomogeneous structure around the CN oscillator. The distribution becomes homogeneous after 5 picoseconds so that spectral diffusion has effectively erased the ‘memory’ of the CN stretching frequency. Therefore, the 2D-IR data of the label incorporated in hemoglobin demonstrate how SCN can be utilized to sense rearrangements in the local structure on a picosecond timescale.

30 October 2018 in Nature Methods
Verified
Journal Article
Closed access
PDF file
ESEike C. Schulz
Eike C. Schulz
PMPedram Mehrabi
Pedram Mehrabi
HMHenrike Mueller-Werkmeister
Henrike Mueller-Werkmeister
FTFriedjof Tellkamp
Friedjof Tellkamp
AJAjay Jha
Ajay Jha
RMR. J. Dwayne Miller
R. J. Dwayne Miller

27 July 2016 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
SOSaeed Oghbaey
Saeed Oghbaey
ASAntoine Sarracini
Antoine Sarracini
HGHelen M. Ginn
Helen M. Ginn
OPOlivier Pare-Labrosse
Olivier Pare-Labrosse
AKAnling Kuo
Anling Kuo
RMR. J. Dwayne Miller
R. J. Dwayne Miller
The advent of ultrafast highly brilliant coherent X-ray free-electron laser sources has driven the development of novel structure-determination approaches for proteins, and promises visualization of protein dynamics on sub-picosecond timescales with full atomic resolution. Significant efforts are being applied to the development of sample-delivery systems that allow these unique sources to be most efficiently exploited for high-throughput serial femtosecond crystallography. Here, the next iteration of a fixed-target crystallography chip designed for rapid and reliable delivery of up to 11 259 protein crystals with high spatial precision is presented. An experimental scheme for predetermining the positions of crystals in the chip by means ofin situspectroscopy using a fiducial system for rapid, precise alignment and registration of the crystal positions is presented. This delivers unprecedented performance in serial crystallography experiments at room temperature under atmospheric pressure, giving a raw hit rate approaching 100% with an effective indexing rate of approximately 50%, increasing the efficiency of beam usage and allowing the method to be applied to systems where the number of crystals is limited.