Iolanda Aquila

Dr. Iolanda Aquila

University Magna Graecia of Catanzaro

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
QCQuirino Ciampi
Quirino Ciampi
FAFrancesco Antonini-Canterin
Francesco Antonini-Canterin
ABAndrea Barbieri
Andrea Barbieri
ABAgata Barchitta
Agata Barchitta
FBFrank Benedetto
Frank Benedetto
S(SIECoVId Study Group, on Behalf of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
SIECoVId Study Group, on Behalf of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
Background: Cardiology divisions reshaped their activities during the coronavirus disease 2019 (COVID-19) pandemic. This study aimed to analyze the organization of echocardiographic laboratories and echocardiography practice during the second wave of the COVID-19 pandemic in Italy, and the expectations for the post-COVID era. Methods: We analyzed two different time periods: the month of November during the second wave of the COVID-19 pandemic (2020) and the identical month during 2019 (November 2019). Results: During the second wave of the COVID-19 pandemic, the hospital activity was partially reduced in 42 (60%) and wholly interrupted in 3 (4%) echocardiographic laboratories, whereas outpatient echocardiographic activity was partially reduced in 41 (59%) and completely interrupted in 7 (10%) laboratories. We observed an important change in the organization of activities in the echocardiography laboratory which reduced the operator-risk and improved self-protection of operators by using appropriate personal protection equipment. Operators wore FFP2 in 58 centers (83%) during trans-thoracic echocardiography (TTE), in 65 centers (93%) during transesophageal echocardiography (TEE) and 63 centers (90%) during stress echocardiography. The second wave caused a significant reduction in number of echocardiographic exams, compared to November 2019 (from 513 ± 539 to 341 ± 299 exams per center, −34%, p < 0.001). On average, there was a significant increase in the outpatient waiting list for elective echocardiographic exams (from 32.0 ± 28.1 to 45.5 ± 44.9 days, +41%, p < 0.001), with a reduction of in-hospital waiting list (2.9 ± 2.4 to 2.4 ± 2.0 days, −17%, p < 0.001). We observed a large diffusion of point-of-care cardiac ultrasound (88%), with a significant increase of lung ultrasound usage in 30 centers (43%) during 2019, extended to all centers in 2020. Carbon dioxide production by examination is an indicator of the environmental impact of technology (100-fold less with echocardiography compared to other cardiac imaging techniques). It was ignored in 2019 by 100% of centers, and currently it is considered potentially crucial for decision-making in cardiac imaging by 65 centers (93%). Conclusions: In one year, major changes occurred in echocardiography practice and culture. The examination structure changed with extensive usage of point-of-care cardiac ultrasound and with lung ultrasound embedded by default in the TTE examination, as well as the COVID-19 testing.

1 December 2015 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
IAIolanda Aquila
Iolanda Aquila
AGAriana González
Ariana González
CFCovadonga Fernández-Golfín
Covadonga Fernández-Golfín
LRLuis Miguel Rincón
Luis Miguel Rincón
ECEduardo Casas
Eduardo Casas
JZJosé Luis Zamorano
José Luis Zamorano
3D transesophageal echocardiography (TEE) is superior to 2D TEE in quantitative anatomic evaluation of the mitral valve (MV) but it shows limitations regarding automatic quantification. Here, we tested the inter-/intra-observer reproducibility of a novel full-automated software in the evaluation of MV anatomy compared to manual 3D assessment. Thirty-six out of 61 screened patients referred to our Cardiac Imaging Unit for TEE were retrospectively included. 3D TEE analysis was performed both manually and with the automated software by two independent operators. Mitral annular area, intercommissural distance, anterior leaflet length and posterior leaflet length were assessed. A significant correlation between both methods was found for all variables: intercommissural diameter (r = 0.84, p < 0.01), mitral annular area (r = 0.94, p > 0, 01), anterior leaflet length (r = 0.83, p < 0.01) and posterior leaflet length (r = 0.67, p < 0.01). Interobserver variability assessed by the intraclass correlation coefficient was superior for the automatic software: intercommisural distance 0.997 vs. 0.76; mitral annular area 0.957 vs. 0.858; anterior leaflet length 0.963 vs. 0.734 and posterior leaflet length 0.936 vs. 0.838. Intraobserver variability was good for both methods with a better level of agreement with the automatic software. The novel 3D automated software is reproducible in MV anatomy assessment. The incorporation of this new tool in clinical MV assessment may improve patient selection and outcomes for MV interventions as well as patient diagnosis and prognosis stratification. Yet, high-quality 3D images are indispensable.

Verified
Journal Article
Open access
PDF file
LRLetizia Rosa Romano
Letizia Rosa Romano
GSGiuseppe Scalzi
Giuseppe Scalzi
BMBiagio Malizia
Biagio Malizia
IAIolanda Aquila
Iolanda Aquila
APAlberto Polimeni
Alberto Polimeni
ACAntonio Curcio
Antonio Curcio
Transcatheter edge-to-edge repair (TEER) currently represents a valuable therapeutic option for patients with severe mitral regurgitation (MR) considered at high surgical risk. Besides symptoms and left ventricular (LV) echocardiographic improvements upon TEER, it has been postulated that left atrial (LA) function plays a prognostic role. The aims of our study were to evaluate LA changes after TEER, measured by two-dimensional speckle-tracking echocardiography analysis (2D-STE), their association with atrial fibrillation (AF) occurrence, and relative arrhythmic burden. We considered in a single-center study 109 patients affected by symptomatic severe MR undergoing TEER from February 2015 to April 2022. By 2D-STE, LA reservoir (R_s), conduct (D_s), and contractile (C_s) strains were assessed along with four-chamber emptying fraction (LAEF-4CH) before, 1, 6, and 12 months following TEER. Statistical analysis for comparison among baseline, and follow-ups after TEER was carried out by ANOVA, MANOVA, and linear regression. Successful TEER significantly improved LV dimensions and LA performances, as indicated by all strain components, and LAEF-4CH after 1 year. Strikingly, a significant reduction in arrhythmic burden was observed, since only one case of subclinical AF detected by a previously implanted cardiac electronic device was found in the cohort of sinus rhythm patients (n = 48) undergone TEER; in addition, ventricular rate was reduced in the AF cohort (n = 61) compared to baseline, together with few episodes of nonsustained ventricular tachycardias (5/61, 8.2%) after MR improvement. Overall, TEER was associated with improved cardiac performance, LA function amelioration, and reduced arrhythmic burden.

1 December 2016 in Medicine
Verified
Journal Article
Open access
IAIolanda Aquila
Iolanda Aquila
CGCovadonga Fernández Golfín
Covadonga Fernández Golfín
LRLuis Miguel Rincón
Luis Miguel Rincón
AGAriana González
Ariana González
AMAna García Martín
Ana García Martín
JZJose Luis Zamorano
Jose Luis Zamorano
Three-dimensional (3D) transesophageal echocardiography (TEE) is the gold standard for mitral valve (MV) anatomic and functional evaluation. Currently, dedicated MV analysis software has limitations for its use in clinical practice. Thus, we tested here a complete and reproducible evaluation of a new fully automatic software to characterize MV anatomy in different forms of mitral regurgitation (MR) by 3D TEE.Sixty patients were included: 45 with more than moderate MR (28 organic MR [OMR] and 17 functional MR [FMR]) and 15 controls. All patients underwent TEE. 3D MV images obtained using 3D zoom were imported into the new software for automatic analysis. Different MV parameters were obtained and compared. Anatomic and dynamic differences between FMR and OMR were detected. A significant increase in systolic (859.75 vs 801.83 vs 607.78 mm; P = 0.002) and diastolic (1040.60 vs. 1217.83 and 859.74 mm; P < 0.001) annular sizes was observed in both OMR and FMR compared to that in controls. FMR had a reduced mitral annular contraction compared to degenerative cases of OMR and to controls (17.14% vs 32.78% and 29.89%; P = 0.007). Good reproducibility was demonstrated along with a short analysis time (mean 4.30 minutes).Annular characteristics and dynamics are abnormal in both FMR and OMR. Full 3D software analysis automatically calculates several significant parameters that provide a correct and complete assessment of anatomy and dynamic mitral annulus geometry and displacement in the 3D space. This analysis allows a better characterization of MR pathophysiology and could be useful in designing new devices for MR repair or replacement.