Wei Tan

Mrs. Wei Tan

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Therapeutic Advances in Respiratory Disease
Verified
Journal Article
Open access
SLShige Li
Shige Li
BDBing Dai
Bing Dai
YHYusheng Hou
Yusheng Hou
LZLiang Zhang
Liang Zhang
JLJie Liu
Jie Liu
WTWei Tan
Wei Tan
Background: Pulmonary rehabilitation (PR) has demonstrated efficacy in managing long COVID-19, underscoring the need to refine and tailor PR strategies for optimal patient outcomes. Objectives: To evaluate the impact of PR on patients with long COVID-19 and to compare the efficacy of different types and durations of PR interventions. Design: Systematic review and meta-analysis. Data sources and methods: We systematically searched randomized controlled trials (RCTs) of the effectiveness of PR in long COVID-19 patients published before April 2024. The primary outcomes were physical capacity assessed by the 6-minute walking test (6MWT), lung function measured by forced expiratory volume in the first second (FEV1) and forced vital capacity (FVC), health-related quality of life (HRQoL), and fatigue. Secondary outcomes were thirty-second sit-to-stand test (30STST), handgrip strength tests, maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP), dyspnea, depression, anxiety, perceived effort, and adverse events. Results: A total of 37 studies with 3363 patients were included. Compared to controls, PR improved physical capacity (6MWT, 30STST, handgrip), lung function (FEV1, FVC, MIP, MEP), HRQoL, fatigue, dyspnea, and anxiety but did not reach statistical significance for depression. Subgroup analyses of PR duration indicated that programs of ⩽4 weeks improved 6MWT; those between 4 and 8 weeks significantly improved 6MWT, lung function (FEV1, FVC), HRQoL, and reduced fatigue; and programs over 8 weeks improved HRQoL and reduced fatigue. Exercise type analysis revealed that breathing exercises improved 6MWT, lung function (FEV1, FVC), and HRQoL; multicomponent exercises enhanced 6MWT performance and reduced fatigue; the combination of both types improved 6MWT, FEV1 (L), FVC (%pred), HRQoL, and reduced fatigue. Conclusion: PR improves physical capacity, lung function, and quality of life and alleviates dyspnea, fatigue, and anxiety in long COVID-19 patients. A 4- to 8-week PR program and a combination of both breath exercises and multicomponent training is most effective for managing long-term COVID-19 syndromes. Trial registration: PROSPERO ID: CRD42024455008.

1 January 2021 in Therapeutic Advances in Respiratory Disease
Verified
Journal Article
Open access
PDF file
WTWei Tan
Wei Tan
DXDong-Yang Xu
Dong-Yang Xu
MXMeng-Jiao Xu
Meng-Jiao Xu
ZWZan-Feng Wang
Zan-Feng Wang
BDBing Dai
Bing Dai
JKJian Kang
Jian Kang
Background and aims: The application of prone positioning with acute hypoxemic respiratory failure (AHRF) or acute respiratory distress syndrome (ARDS) in non-intubation patients is increasing gradually, applying prone positioning for more high-flow nasal oxygen therapy (HFNC) and non-invasive ventilation (NIV) patients. This meta-analysis evaluates the efficacy and tolerance of prone positioning combined with non-invasive respiratory support in patients with AHRF or ARDS. Methods: We searched randomized controlled trials (RCTs) (prospective or retrospective cohort studies, RCTs and case series) published in PubMed, EMBASE and the Cochrane Central Register of Controlled Trials from 1 January 2000 to 1 July 2020. We included studies that compared prone and supine positioning with non-invasive respiratory support in awake patients with AHRF or ARDS. The meta-analyses used random effects models. The methodological quality of the RCTs was evaluated using the Newcastle–Ottawa quality assessment scale. Results: A total of 16 studies fulfilled selection criteria and included 243 patients. The aggregated intubation rate and mortality rate were 33% [95% confidence interval (CI): 0.26–0.42, I2 = 25%], 4% (95% CI: 0.01–0.07, I2 = 0%), respectively, and the intolerance rate was 7% (95% CI: 0.01–0.12, I2 = 5%). Prone positioning increased PaO2/FiO2 [mean difference (MD) = 47.89, 95% CI: 28.12–67.66; p < 0.00001, I2 = 67%] and SpO2 (MD = 4.58, 95% CI: 1.35–7.80, p = 0.005, I2 = 97%), whereas it reduced respiratory rate (MD = −5.01, 95% CI: −8.49 to −1.52, p = 0.005, I2 = 85%). Subgroup analyses demonstrated that the intubation rate of shorter duration prone (⩽5 h/day) and longer duration prone (>5 h/day) were 34% and 21%, respectively; and the mortality rate of shorter duration prone (⩽5 h/day) and longer duration prone (>5 h/day) were 6% and 0%, respectively. PaO2/FiO2 and SpO2 were significantly improved in COVID-19 patients and non-COVID-19 patients. Conclusion: Prone positioning could improve the oxygenation and reduce respiratory rate in both COVID-19 patients and non-COVID-19 patients with non-intubated AHRF or ARDS. The reviews of this paper are available via the supplemental material section.

21 July 2022 in Therapeutic Advances in Respiratory Disease
Verified
Journal Article
Open access
YPYun Peng
Yun Peng
BDBing Dai
Bing Dai
HZHong-Wen Zhao
Hong-Wen Zhao
WWWei Wang
Wei Wang
JKJian Kang
Jian Kang
WTWei Tan
Wei Tan
Background: High-flow nasal cannula (HFNC) and noninvasive ventilation (NIV) are important treatment approaches for acute hypoxemic respiratory failure (AHRF) in coronavirus disease 2019 (COVID-19) patients. However, the differential impact of HFNC versus NIV on clinical outcomes of COVID-19 is uncertain. Objectives: We assessed the effects of HFNC versus NIV (interface or mode) on clinical outcomes of COVID-19. Methods: We searched PubMed, EMBASE, Web of Science, Scopus, MedRxiv, and BioRxiv for randomized controlled trials (RCTs) and observational studies (with a control group) of HFNC and NIV in patients with COVID-19-related AHRF published in English before February 2022. The primary outcome of interest was the mortality rate, and the secondary outcomes were intubation rate, PaO2/FiO2, intensive care unit (ICU) length of stay (LOS), hospital LOS, and days free from invasive mechanical ventilation [ventilator-free day (VFD)]. Results: In all, 23 studies fulfilled the selection criteria, and 5354 patients were included. The mortality rate was higher in the NIV group than the HFNC group [odds ratio (OR) = 0.66, 95% confidence interval (CI): 0.51–0.84, p = 0.0008, I2 = 60%]; however, in this subgroup, no significant difference in mortality was observed in the NIV-helmet group (OR = 1.21, 95% CI: 0.63–2.32, p = 0.57, I2 = 0%) or NIV-continuous positive airway pressure (CPAP) group (OR = 0.77, 95% CI: 0.51–1.17, p = 0.23, I2 = 65%) relative to the HFNC group. There were no differences in intubation rate, PaO2/FiO2, ICU LOS, hospital LOS, or days free from invasive mechanical ventilation (VFD) between the HFNC and NIV groups. Conclusion: Although mortality was lower with HFNC than NIV, there was no difference in mortality between HFNC and NIV on a subgroup of helmet or CPAP group. Future large sample RCTs are necessary to prove our findings. Registration: This systematic review and meta-analysis protocol was prospectively registered with PROSPERO (no. CRD42022321997).

26 April 2024 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
XLXin-Yu Li
Xin-Yu Li
BDBing Dai
Bing Dai
HHHai-Jia Hou
Hai-Jia Hou
HZHong-Wen Zhao
Hong-Wen Zhao
WWWei Wang
Wei Wang
WTWei Tan
Wei Tan
It remains unclear whether conservative oxygen therapy (COT) or liberal oxygen therapy (LOT) is more beneficial to the clinical outcomes of intensive care unit (ICU) patients. We systematically reviewed the efficacy and safety of conservative versus liberal oxygen therapy for ICU patients. We systematically searched PubMed, Embase, Web of Science, Scopus, Cochrane Central Register of Controlled Trials, ClinicalTrials.gov, MedRxiv, and BioRxiv for reports on randomized controlled trials (RCTs) that compared the effects of COT versus LOT on the clinical outcomes of ICU patients published in English before April 2024. The primary outcome was the mortality rate, secondary outcomes included ICU and hospital length of stay, days free from mechanical ventilation support (MVF), vasopressor-free time (VFT), and adverse events. In all, 13 RCTs involving 10,632 patients were included in analyses. Meta-analysis showed COT did not reduce mortality at 30-day (risk ratio [RR] = 1.01, 95% confidence interval [CI] 0.94 to 1.09, I2 = 42%, P = 0.78), 90-day (RR = 1.01, 95% CI 0.95 to 1.08, I2 = 9%, P = 0.69), or longest follow-up (RR = 1.00, 95% CI 0.95 to 1.06, I2 = 22%, P = 0.95) compared to LOT in ICU patients. In subgroup analyses, no significant difference was observed between the two groups in terms of the different ICU, baseline P/F, and actual PaO2. In addition, COT did not affect ICU length of stay, hospital length of stay, or VFT, it only affected MVF days. COT did not reduce all-cause mortality in ICU patients. Further RCTs are urgently needed to confirm the impact of COT strategy on specific populations.

1 January 2022 in Therapeutic Advances in Respiratory Disease
Verified
Journal Article
Open access
DXDong-Yang Xu
Dong-Yang Xu
BDBing Dai
Bing Dai
WTWei Tan
Wei Tan
HZHong-Wen Zhao
Hong-Wen Zhao
WWWei Wang
Wei Wang
JKJian Kang
Jian Kang
Background: Coronavirus disease 2019 (COVID-19) has spread globally, and many patients with severe cases have received oxygen therapy through a high-flow nasal cannula (HFNC). Objectives: We assessed the efficacy of HFNC for treating patients with COVID-19 and risk factors for HFNC failure. Methods: We searched PubMed, Embase, and the Cochrane Central Register of randomized controlled trials (RCTs) and observational studies of HFNC in patients with COVID-19 published in English from January 1st, 2020 to August 15th, 2021. The primary aim was to assess intubation, mortality, and failure rates in COVID-19 patients supported by HFNC. Secondary aims were to compare HFNC success and failure groups and to describe the risk factors for HFNC failure. Results: A total of 25 studies fulfilled selection criteria and included 2851 patients. The intubation, mortality, and failure rates were 0.44 (95% confidence interval (CI): 0.38–0.51, I2 = 84%), 0.23 (95% CI: 0.19–0.29, I2 = 88%), and 0.47 (95% CI: 0.42–0.51, I2 = 56%), respectively. Compared to the success group, age, body mass index (BMI), Sequential Organ Failure Assessment (SOFA) score, Acute Physiology and Chronic Health Evaluation (APACHE) II score, D-dimer, lactate, heart rate, and respiratory rate were higher and PaO2, PaO2/FiO2, ROX index (the ratio of SpO2/FiO2 to respiratory rate), ROX index after the initiation of HFNC, and duration of HFNC were lower in the failure group (all Ps < 0.05). There were also more smokers and more comorbidities in the failure group (all Ps < 0.05). Pooled odds ratios (ORs) revealed that older age (OR: 1.04, 95% CI: 1.01–1.07, P = 0.02, I2 = 88%), a higher white blood cell (WBC) count (OR: 1.06, 95% CI: 1.01–1.12, P = 0.02, I2 = 0%), a higher heart rate (OR: 1.42, 95% CI: 1.15–1.76, P < 0.01, I2 = 0%), and a lower ROX index(OR: 0.61, 95% CI: 0.39–0.95, P = 0.03, I2 = 93%) after the initiation of HFNC were all significant risk factors for HFNC failure. Conclusions: HFNC is an effective way of providing respiratory support in the treatment of COVID-19 patients. Older age, a higher WBC count, a higher heart rate, and a lower ROX index after the initiation of HFNC are associated with an increased risk of HFNC failure.

10 October 2022 in Frontiers in Medicine
Verified
Journal Article
Open access
HHHaijia Hou
Haijia Hou
DXDongyang Xu
Dongyang Xu
BDBing Dai
Bing Dai
HZHongwen Zhao
Hongwen Zhao
WWWei Wang
Wei Wang
WTWei Tan
Wei Tan
Background: The optimal positions of different types of nebulizer for aerosol delivery remain unclear.Methods: Three ICU ventilators employing three types of nebulizer were separately connected to a simulated lung to simulate nebulization during invasive ventilation. Assist/control-pressure control (A/C-PC) mode was utilized, with inspiratory pressure (Pi) set to 12 cmH2O and positive end expiratory pressure (PEEP) set to 5 cmH2O, and with a target Vt of 500 ml. The bias flow of all the ventilators was set to 2 L/min. The three nebulizers were the continuous jet nebulizer (c-JN), the inspiratory synchronized jet nebulizer (i-JN), and the vibrating mesh nebulizer (VMN). The five nebulizer positions were as follows: at the Y-piece (position 1) and 15 cm from the Y-piece (position 2) between the endotracheal tube and the Y-piece, at the Y-piece (position 3) and 15 cm from the Y-piece (position 4) in the inspiratory limb; and at the humidifier inlet (position 5). Aerosols were collected with a disposable filter placed at the simulated lung outlet (n = 3) and were measured by UV spectrophotometry (276 nm). The measurements were compared under different experimental conditions.Results: The aerosol delivery of c-JN, i-JN, and VMN was 5.33 ± 0.49~11.12 ± 0.36%, 7.73 ± 0.76~13.75 ± 0.46% and 11.13 ± 56–30.2 ± 1.63%, respectively. The higher aerosol delivery: for c-JN~Positions 2 (10.95 ± 0.15%), fori-JN~Positions 1 or 2 (12.91 ± 0.88% or 13.45 ± 0.42%), for VMN~Positions 4(29.03 ± 1.08%); the lower aerosol delivery: for c-JN~Positions 1, 3 or 5, fori-JN~Positions 4 or 5, for VMN~Positions 5.The highest aerosol delivery:For c-JN at Position 2 (10.95 ± .15%), for i-JN at Position 1 or 2 (12.91 ± .88% or 13.45 ± .42%), for VMN at Positions 4 (29. 03 ± 1.08%); the lower aerosol delivery: for c-JN at Positions 1, 3 or 5, for i-JN at Positions 4 or 5, for VMN at Positions 5. The highest aerosol deliveryof c-JN was lower than that of i-JN while the VMN was the highest (all P < .05). However, no differences were observed between the highest aerosol delivery with c-JN and the lowest aerosol delivery with i-JN. Similar results were found between the lowest aerosol delivery with VMN and the highest aerosol delivery with c-JN /i-JN in the Avea ventilator. There were no differences in the highest aerosol delivery of each nebulizer among the different ventilators (all p > 0.05).Conclusion: During adult mechanical ventilation, the type and position of nebulizer influences aerosol delivery efficiency, with no differences between ventilators.