Sangchul Lee

Dr. Sangchul Lee


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SBSungje Bock
Sungje Bock
HKHyung-Mo Kim
Hyung-Mo Kim
JKJaehi Kim
Jaehi Kim
JAJaehyun An
Jaehyun An
YCYun-Sik Choi
Yun-Sik Choi
Bong-Hyun JunBong-Hyun Jun
Bong-Hyun Jun
Prostate cancer can be detected early by testing the presence of prostate-specific antigen (PSA) in the blood. Lateral flow immunoassay (LFIA) has been used because it is cost effective and easy to use and also has a rapid sample-to-answer process. Quantum dots (QDs) with very bright fluorescence have been previously used to improve the detection sensitivity of LFIAs. In the current study, a highly sensitive LFIA kit was devised using QD-embedded silica nanoparticles. In the present study, only a smartphone and a computer software program, ImageJ, were used, because the developed system had high sensitivity by using very bright nanoprobes. The limit of PSA detection of the developed LFIA system was 0.138 ng/mL. The area under the curve of this system was calculated as 0.852. The system did not show any false-negative result when 47 human serum samples were analyzed; it only detected PSA and did not detect alpha-fetoprotein and newborn calf serum in the samples. Additionally, fluorescence was maintained on the strip for 10 d after the test. With its high sensitivity and convenience, the devised LFIA kit can be used for the diagnosis of prostate cancer.

12 March 2021 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
HKHyung-Mo Kim
Hyung-Mo Kim
JKJaehi Kim
Jaehi Kim
JAJaehyun An
Jaehyun An
SBSungje Bock
Sungje Bock
XPXuan-Hung Pham
Xuan-Hung Pham
Bong-Hyun JunBong-Hyun Jun
Bong-Hyun Jun
Background: Blood prostate-specific antigen (PSA) levels are widely used as diagnostic biomarkers for prostate cancer. Lateral-flow immunoassay (LFIA)-based PSA detection can overcome the limitations associated with other methods. LFIAbased PSA detection in clinical samples enables prognosis and early diagnosis owing to the use of high-performance signal reporters. Results: Here, a semiquantitative LFIA platform for PSA detection in blood was developed using Au–Ag nanoparticles (NPs) assembled on silica NPs (SiO2@Au–Ag NPs) that served as signal reporters. Synthesized SiO2@Au–Ag NPs exhibited a high absorbance at a wide wavelength range (400–800 nm), with a high scattering on nitrocellulose membrane test strips. In LFIA, the color intensity of the test line on the test strip differed depending on the PSA concentration (0.30–10.00 ng/mL), and bands for the test line on the test strip could be used as a standard. When clinical samples were assessed using this LFIA, a visual test line with particular color intensity observed on the test strip enabled the early diagnosis and prognosis of patients with prostate cancer based on PSA detection. In addition, the relative standard deviation of reproducibility was 1.41%, indicating high reproducibility, and the signal reporter showed good stability for 10 days. Conclusion: These characteristics of the signal reporter demonstrated the reliability of the LFIA platform for PSA detection, suggesting potential applications in clinical sample analysis.


30 June 2021 in International Neurourology Journal
Verified
Journal Article
Open access
PDF file
YLYoung Ju Lee
Young Ju Lee
MKMichelle M. Kim
Michelle M. Kim
SSSang Hoon Song
Sang Hoon Song
SLSangchul Lee
Sangchul Lee
Purpose: This study aimed to evaluate the accuracy and reliability of a new smartphone-based acoustic uroflowmetry compared to conventional uroflowmetry.Methods: This was a prospective validation study enrolling 128 subjects from September 2017 to April 2018 comparing a novel acoustic uroflowmetry to conventional uroflowmetry in an outpatient urologic clinic at Seoul National University Bundang Hospital. Visual comparison of flow patterns and uroflow parameters such as maximum flow rate (Qmax), average flow rate (Qavg), and voided volume were compared between the 2 techniques. Reliability and accuracy of the uroflowmetry results were compared using Pearson correlation coefficient (PCC) and Student t-test, respectively.Results: One hundred twelve participants were included in the study. Of these, 77 had baseline urologic comorbidities while 35 were normal participants. Flow patterns between the 2 uroflowmetry techniques demonstrated strong visual correlation. When compared to conventional uroflowmetry, all 3 parameters of voiding in male participants showed a very robust correlation with PCC of 0.88, 0.91, and 0.95 for Qmax, Qavg, and voided volume, respectively. Among female participants, we observed a PCC of 0.78, 0.93, and 0.96 for Qmax, Qavg, and voided volume, respectively. The Qmax showed a statistically significant difference in both sexes between the 2 methods, although the absolute value was small.Conclusions: Uroflowmetry using acoustic analysis demonstrates comparable findings to conventional uroflowmetry. This provides an opportunity to perform uroflowmetry in the clinic or at home in a reliable, inexpensive manner. Future large-scale prospective studies are required to further validate our results.

15 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HKHyung-Mo Kim
Hyung-Mo Kim
JKJaehi Kim
Jaehi Kim
SBSungje Bock
Sungje Bock
JAJaehyun An
Jaehyun An
YCYun-Sik Choi
Yun-Sik Choi
Bong-Hyun JunBong-Hyun Jun
Bong-Hyun Jun
Prostate-specific antigen (PSA) is the best-known biomarker for early diagnosis of prostate cancer. For prostate cancer in particular, the threshold level of PSA <4.0 ng/mL in clinical samples is an important indicator. Quick and easy visual detection of the PSA level greatly helps in early detection and treatment of prostate cancer and reducing mortality. In this study, we developed optimized silica-coated silver-assembled silica nanoparticles (SiO2@Ag@SiO2 NPs) that were applied to a visual lateral flow immunoassay (LFIA) platform for PSA detection. During synthesis, the ratio of silica NPs to silver nitrate changed, and as the synthesized NPs exhibited distinct UV spectra and colors, most optimized SiO2@Ag@SiO2 NPs showed the potential for early prostate cancer diagnosis. The PSA detection limit of our LFIA platform was 1.1 ng/mL. By applying each SiO2@Ag@SiO2 NP to the visual LFIA platform, optimized SiO2@Ag@SiO2 NPs were selected in the test strip, and clinical samples from prostate cancer patients were successfully detected as the boundaries of non-specific binding were clearly seen and the level of PSA was <4 ng/mL, thus providing an avenue for quick prostate cancer diagnosis and early treatment.

21 February 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
SHSeong-Hye Hwang
Seong-Hye Hwang
SLSangchul Lee
Sangchul Lee
JPJee Yoon Park
Jee Yoon Park
JJJessie Jeon
Jessie Jeon
YCYoung-Jae Cho
Young-Jae Cho
Sejoong KimSejoong Kim
Sejoong Kim
Organ-on-a-chip (OoC) is an exponential technology with the potential to revolutionize disease, toxicology research, and drug discovery. Recent advances in OoC could be utilized for drug screening in disease models to evaluate the efficacy of new therapies and support new tools for the understanding of disease mechanisms. Rigorous validation of this technology is required to determine whether OoC models may represent human-relevant physiology and predict clinical outcomes in target disease models. Achievements in the OoC field could reveal exciting new avenues for drug development and discovery. This review attempts to highlight the benefits of OoC as per our understanding of the cellular and molecular pathways in lung and kidney cancer models, and discusses the challenges in evaluating drug efficacy.