Joey Roosen

Mr. Joey Roosen

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2019 in EJNMMI Radiopharmacy and Chemistry
Verified
Journal Article
Open access
PDF file
NKNienke J. M. Klaassen
Nienke J. M. Klaassen
MAMark Arntz
Mark Arntz
AAAlexandra Gil Arranja
Alexandra Gil Arranja
JRJoey Roosen
Joey Roosen
JNJohannes Frank Wilhelmus Nijsen
Johannes Frank Wilhelmus Nijsen
Over the years, a broad spectrum of applications of the radionuclide holmium-166 as a medical isotope has been established. The isotope holmium-166 is attractive as it emits high-energy beta radiation which can be used for a therapeutic effect and gamma radiation which can be used for nuclear imaging purposes. Furthermore, holmium-165 can be visualized by MRI because of its paramagnetic properties and by CT because of its high density. Since holmium-165 has a natural abundance of 100%, the only by-product is metastable holmium-166 and no costly chemical purification steps are necessary for production of nuclear reactor derived holmium-166. Several compounds labelled with holmium-166 are now used in patients, such Ho166-labelled microspheres for liver malignancies, Ho166-labelled chitosan for hepatocellular carcinoma (HCC) and [166Ho]Ho DOTMP for bone metastases. The outcomes in patients are very promising, making this isotope more and more interesting for applications in interventional oncology. Both drugs as well as medical devices labelled with radioactive holmium are used for internal radiotherapy. One of the treatment possibilities is direct intratumoural treatment, in which the radioactive compound is injected with a needle directly into the tumour. Numerous other applications have been developed, like patches for treatment of skin cancer and holmium labelled antibodies and peptides. The second major application that is currently clinically applied is selective internal radiation therapy (SIRT, also called radioembolization), a novel treatment option for liver malignancies. This review discusses medical drugs and medical devices based on the therapeutic radionuclide holmium-166.

10 April 2021 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
JRJoey Roosen
Joey Roosen
NKNienke J. M. Klaassen
Nienke J. M. Klaassen
LGLovisa Westlund Gotby
Lovisa Westlund Gotby
COChristiaan Overduin
Christiaan Overduin
MVMarcel Verheij
Marcel Verheij
JNJohannes Frank Wilhelmus Nijsen
Johannes Frank Wilhelmus Nijsen
Purpose: To systematically review all current evidence into the dose-response relation of yttrium-90 and holmium-166 selective internal radiation therapy (SIRT) in primary and secondary liver cancer. Methods: A standardized search was performed in PubMed (MEDLINE), Embase, and the Cochrane Library in order to identify all published articles on dose-response evaluation in SIRT. In order to limit the results, all articles that investigated SIRT in combination with other therapy modalities (such as chemotherapy) were excluded. Results: A total of 3038 records were identified of which 487 were screened based on the full text. Ultimately, 37 studies were included for narrative analysis. Meta-analysis could not be performed due to the large heterogeneity in study and reporting designs. Out of 37 studies, 30 reported a ‘mean dose threshold’ that needs to be achieved in order to expect a response. This threshold appears to be higher for hepatocellular carcinoma (HCC, 100–250 Gy) than for colorectal cancer metastases (CRC, 40–60 Gy). Reported thresholds tend to be lower for resin microspheres than when glass microspheres are used. Conclusion: Although the existing evidence demonstrates a dose-response relationship in SIRT for both primary liver tumours and liver metastases, many pieces of the puzzle are still missing, hampering the definition of standardized dose thresholds. Nonetheless, most current evidence points towards a target mean dose of 100–250 Gy for HCC and 40–60 Gy for CRC. The field would greatly benefit from a reporting standard and prospective studies designed to elucidate the dose-response relation in different tumour types.

13 July 2022 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
JRJoey Roosen
Joey Roosen
LGLovisa Westlund Gotby
Lovisa Westlund Gotby
MAMark Arntz
Mark Arntz
JFJurgen Fütterer
Jurgen Fütterer
MJMarcel J. R. Janssen
Marcel J. R. Janssen
JNJohannes Frank Wilhelmus Nijsen
Johannes Frank Wilhelmus Nijsen
Purpose: Transarterial radioembolization (TARE) is a treatment for liver tumours based on injection of radioactive microspheres in the hepatic arterial system. It is crucial to achieve a maximum tumour dose for an optimal treatment response, while minimizing healthy liver dose to prevent toxicity. There is, however, no intraprocedural feedback on the dose distribution, as nuclear imaging can only be performed after treatment. As holmium-166 (166Ho) microspheres can be quantified with MRI, we investigate the feasibility and safety of performing 166Ho TARE within an MRI scanner and explore the potential of intraprocedural MRI-based dosimetry. Methods: Six patients were treated with 166Ho TARE in a hybrid operating room. Per injection position, a microcatheter was placed under angiography guidance, after which patients were transported to an adjacent 3-T MRI system. After MRI confirmation of unchanged catheter location, 166Ho microspheres were injected in four fractions, consisting of 10%, 30%, 30% and 30% of the planned activity, alternated with holmium-sensitive MRI acquisition to assess the microsphere distribution. After the procedures, MRI-based dose maps were calculated from each intraprocedural image series using a dedicated dosimetry software package for 166Ho TARE. Results: Administration of 166Ho microspheres within the MRI scanner was feasible in 9/11 (82%) injection positions. Intraprocedural holmium-sensitive MRI allowed for tumour dosimetry in 18/19 (95%) of treated tumours. Two CTCAE grade 3–4 toxicities were observed, and no adverse events were attributed to treatment in the MRI. Towards the last fraction, 4/18 tumours exhibited signs of saturation, while in 14/18 tumours, the microsphere uptake patterns did not deviate from the linear trend. Conclusion: This study demonstrated feasibility and preliminary safety of a first in-human application of TARE within a clinical MRI system. Intraprocedural MRI-based dosimetry enabled dynamic insight in the microsphere distribution during TARE. This proof of concept yields unique possibilities to better understand microsphere distribution in vivo and to potentially optimize treatment efficacy through treatment personalization. Registration: Clinicaltrials.gov, identifier NCT04269499, registered on February 13, 2020 (retrospectively registered).

21 June 2023 in Drug Delivery
Verified
Journal Article
Open access
TST. J. Snoeijink
T. J. Snoeijink
TVT. G. Vlogman
T. G. Vlogman
JRJoey Roosen
Joey Roosen
EJE. Groot Jebbink
E. Groot Jebbink
KJKartik Jain
Kartik Jain
JNJohannes Frank Wilhelmus Nijsen
Johannes Frank Wilhelmus Nijsen
[Purpose] Transarterial radioembolization (TARE) is an established treatment modality for patients with unresectable liver cancer. However, a better understanding of treatment parameters that influence microsphere distribution could further improve the therapy. This systematic review examines and summarizes the available evidence on intraprocedural parameters that influence the microsphere distribution during TARE as investigated by in vivo, ex vivo, in vitro and in silico studies. [Methods] A standardized search was performed in Medline, Embase and Web of Science to identify all published articles investigating microsphere distribution or dynamics during TARE. Studies presenting original research on parameters influencing the microsphere distribution during TARE were included. [Results] A total of 42 studies reporting a total of 11 different parameters were included for narrative analysis. The investigated studies suggest that flow distribution is not a perfect predictor of microsphere distribution. Increasing the injection velocity may help increase the similarity between flow and microsphere distributions. Furthermore, the microsphere distributions are very sensitive to the radial and axial catheter position. [Conclusion] The most promising parameters for future research which can be controlled in the clinic appear to be microsphere injection velocity as well as the axial catheter position. Up to now, many of the included studies do not take clinical feasibility into account, limiting the translation of results to clinical settings. Future research should therefore focus on the applicability of in vivo, in vitro, or in silico research to patient specific scenarios to improve the efficacy of radioembolization as treatment for liver cancer.

30 October 2021 in Cancers
Verified
Journal Article
Open access
PDF file
JRJoey Roosen
Joey Roosen
MAMark Arntz
Mark Arntz
MJMarcel J. R. Janssen
Marcel J. R. Janssen
SJSytse de Jong
Sytse de Jong
JFJurgen Fütterer
Jurgen Fütterer
JNJohannes Frank Wilhelmus Nijsen
Johannes Frank Wilhelmus Nijsen
Selective internal radiation therapy (SIRT) is a treatment modality for liver tumours during which radioactive microspheres are injected into the hepatic arterial tree. Holmium-166 (166Ho) microspheres used for SIRT can be visualized and quantified with MRI, potentially allowing for MRI guidance during SIRT. The purpose of this study was to investigate the MRI compatibility of two angiography catheters and a microcatheter typically used for SIRT, and to explore the detectability of 166Ho microspheres in a flow phantom using near real-time MRI. MR safety tests were performed at a 3 T MRI system according to American Society for Testing of Materials standard test methods. To assess the near real-time detectability of 166Ho microspheres, a flow phantom was placed in the MRI bore and perfused using a peristaltic pump, simulating the flow in the hepatic artery. Dynamic MR imaging was performed using a 2D FLASH sequence during injection of different concentrations of 166Ho microspheres. In the safety assessment, no significant heating (ΔTmax 0.7 °C) was found in any catheter, and no magnetic interaction was found in two out of three of the used catheters. Near real-time MRI visualization of 166Ho microsphere administration was feasible and depended on holmium concentration and vascular flow speed. Finally, we demonstrate preliminary imaging examples on the in vivo catheter visibility and near real-time imaging during 166Ho microsphere administration in an initial patient case treated with SIRT in a clinical 3 T MRI. These results support additional research to establish the feasibility and safety of this procedure in vivo and enable the further development of a personalized MRI-guided approach to SIRT.

8 February 2024 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
PHPim Hendriks
Pim Hendriks
DRDaphne D. D. Rietbergen
Daphne D. D. Rietbergen
AEArian R. van Erkel
Arian R. van Erkel
MCMinneke J. Coenraad
Minneke J. Coenraad
MAMark Arntz
Mark Arntz
DGDutch Hepatocellular and Cholangiocarcinoma Group
Dutch Hepatocellular and Cholangiocarcinoma Group
Purpose: The aim of this study was to investigate the biodistribution of (super-)selective trans-arterial radioembolization (TARE) with holmium-166 microspheres (166Ho-MS), when administered as adjuvant therapy after RFA of HCC 2–5 cm. The objective was to establish a treatment volume absorbed dose that results in an absorbed dose of ≥ 120 Gy on the hyperemic zone around the ablation necrosis (i.e., target volume). Methods: In this multicenter, prospective dose-escalation study in BCLC early stage HCC patients with lesions 2–5 cm, RFA was followed by (super-)selective infusion of 166Ho-MS on day 5–10 after RFA. Dose distribution within the treatment volume was based on SPECT-CT. Cohorts of up to 10 patients were treated with an incremental dose (60 Gy, 90 Gy, 120 Gy) of 166Ho-MS to the treatment volume. The primary endpoint was to obtain a target volume dose of ≥ 120 Gy in 9/10 patients within a cohort. Results: Twelve patients were treated (male 10; median age, 66.5 years (IQR, [64.3–71.7])) with a median tumor diameter of 2.7 cm (IQR, [2.1–4.0]). At a treatment volume absorbed dose of 90 Gy, the primary endpoint was met with a median absorbed target volume dose of 138 Gy (IQR, [127–145]). No local recurrences were found within 1-year follow-up. Conclusion: Adjuvant (super-)selective infusion of 166Ho-MS after RFA for the treatment of HCC can be administered safely at a dose of 90 Gy to the treatment volume while reaching a dose of ≥ 120 Gy to the target volume and may be a favorable adjuvant therapy for HCC lesions 2–5 cm. Trial registration: Clinicaltrials.gov NCT03437382. (registered: 19-02-2018)