In this work, the azoxystrobin removal in water by using a micro-size discharge array was investigated, and the removal efficiency can reach as high as 98.1% after 9 min plasma treatment as well as the energy utilization being only 0.73 g/(kW·h). Based on the relationship between the generation of gas bubbles and parameters of gas-liquid discharge, it was found that the variation of applied voltage, gas flow rate and initial solution temperature could cause particle number change, mass transfer rate change and the mass transfer time change, which significantly affected the practical applications at last. The experimental results indicated that when gas flow rate was 0.7 SLM (Standard Liter per Minute) and the initial solution temperature was 297 K with the applied voltage of 8 kV and discharge frequency of 6 kHz, the removal efficiency of azoxystrobin achieved maximum. Based on the analysis results of liquid mass spectrometry, the removal pathways of azoxystrobin were supposed by the decomposed by-products. Toxicity tests indicated that the decomposed products were safe and non-toxic. So, this study may reveal an azoxystrobin degradation mechanism and provide a safe, reliable and effective way for azoxystrobin degradation.
In this paper, the hybrid gas–liquid discharge plasma can efficiently degrade pesticide residues in water driven by nanosecond pulse power, which can achieve the simultaneous discharge process in the liquid and gas phases. The relevant factors are systematically investigated, including the waveforms of discharge current and pulse voltage, discharge images, and optical emission spectra during the discharge process. The Stark broadening of Hα calculates the electron density. The effects of the pulse peak voltage and discharge time on the emission intensities of OH (A2∑ → X2∏), N2 (C3∏u → B3∏g), Hα, and O (3p5P → 3s5S0) are discussed in-depth by the optical emission spectra. The gas–liquid discharge plasma with an electron density of 7.14 × 1017 cm−3 was found. The emission intensities of OH (A2∑ → X2∏), N2 (C3∏u → B3∏g), Hα, and O (3p5P → 3s5S0) present the rising trend by increasing the pulse peak voltage and discharge time. In addition, pyraclostrobin is adopted as the research object to study the removal efficiency of pollutants. The results confirm that pyraclostrobin can be completely degraded after 10 min of plasma treatment with the pulse peak voltage of 28 kV, and the degradation rate and energy yield was 0.323 min−1, and 1.91 g/kWh, respectively. The intermediate products and the possible degradation mechanism of pyraclostrobin are further explored by combining the results of high-performance liquid chromatography–mass spectrometry (HPLC-MS/MS) and density functional theory (DFT), the developmental toxicity of the intermediate products was analyzed, which provided a scheme for the treatment of pesticide wastewater by gas–liquid discharge plasma technology.