Bo Wang

Prof. Dr. Bo Wang

Department of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha 410083, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
XLXiaofei Luo
Xiaofei Luo
YCYiqi Cai
Yiqi Cai
ZCZeyu Chen
Zeyu Chen
HSHan Shan
Han Shan
XSXin Sun
Xin Sun
BWBo Wang
Bo Wang
Current Photoacoustic tomography (PAT) approaches are based on a single-element transducer that exhibits compromised performance in clinical imaging applications. For example, vascular, tumors are likely to have complicated shapes and optical absorptions, covering relatively wide spectra in acoustic signals. The wide ultrasonic spectra make it difficult to set the detection bandwidth optimally in advance. In this work, we propose a stack-layer dual-element ultrasonic transducer for PAT. The central frequencies of the two piezoelectric elements are 3.06 MHz (99.3% bandwidth at –6 dB) and 11.07 MHz (85.2% bandwidth at –6 dB), respectively. This transducer bridges the sensitivity capability of ultrasound and the high contrast of optical methods in functional photoacoustic tomography. The dual-element transducer enabled multiscale analysis of the vascular network in rat brains. Using a multi-wavelength imaging scheme, the blood oxygen saturation was also detected. The preliminary results showed the great potential of broad-bandwidth functional PAT on vascular network visualization. The method can also be extended to whole-body imaging of small animals, breast cancer detection, and finger joint imaging.

27 August 2021 in Photonics
Verified
Journal Article
Open access
PDF file
XLXiaofei Luo
Xiaofei Luo
JXJiaying Xiao
Jiaying Xiao
CWCongcong Wang
Congcong Wang
BWBo Wang
Bo Wang
Photoacoustic computed tomography (PACT) is a fast-developing imaging technique, which can provide structural and functional information in biological tissues with high-resolution beyond the depth of the optical diffusion limit. However, the most current PACT reconstruction method generally employs a point detector assumption, whereas in most PAT systems with circular or spherical scanning modes, the transducer is mostly flat and with a finite size. This model mismatch leads to a notable deterioration in the lateral direction in regions far from the rotation center, which is known as the “finite aperture effect”. In this work, we propose to compensate a novel Back-projection (BP) method based on the transducer’s spatial impulse response (SIR) for fast correction of the “finite aperture effect”. The SIR accounts for the waveform change of the transducer for an arbitrary point source due to the geometry of the detection surface. Simulation results showed that the proposed SIR-BP method can effectively improve the lateral resolution and signal to noise ratio (SNR) in the off-center regions. For a target 4.5 mm far from the rotation center, this new method improved the lateral resolution about five times along with a 7 dB increase in the SNR. Experimental results also showed that this SIR-BP method can well restore the image angular blur to recover small structures, as demonstrated by the imaging of leaf veins. This new method offers a valuable alternative to the conventional BP method, and can guide the design of PAT systems based on circular/spherical scan.

18 September 2024 in Photonics
Verified
Journal Article
Open access
PDF file
NWningning wei
ningning wei
HCHuiting Chen
Huiting Chen
BLBin Li
Bin Li
XDXiaojun Dong
Xiaojun Dong
BWBo Wang
Bo Wang
The rapid progress in biomedical imaging technology has generated considerable interest in new non-invasive photoacoustic endoscopy imaging techniques. This emerging technology offers significant benefits, including high spectral specificity, strong tissue penetration, and real-time multidimensional high-resolution imaging capabilities, which enhance clinical diagnosis and treatment of prostate cancer. This paper delivers a thorough review of current prostate cancer screening techniques, the core principles of photoacoustic endoscopy imaging, and the latest research on its use in detecting prostate cancer. Additionally, the limitations of this technology in prostate cancer detection are discussed, and future development trends are anticipated.

17 October 2026 in Acta Physica Sinica
Verified
Journal Article
Open access
PDF file
HXHuang Xing
Huang Xing
LRLiu Runxiang
Liu Runxiang
ZZZhang Zhanjun
Zhang Zhanjun
BWBo Wang
Bo Wang
光声成像兼具光学成像的高分子对比度和超声成像的高深穿透优势,但其在复杂生物组织中易受血红蛋白等内源性吸收体的强背景干扰。为此,利用具有长寿命三重态的外源性探针,通过泵浦探测的方法来去除血液背景的影响,已成为光声成像的重要发展方向。本文建立了一套高灵敏的纳秒级瞬态吸收光谱检测方法,引入了参考光同步双通道监测机制,从而有效减少激光能量波动引起的测量误差,在420到900 nm的宽谱波段内,实现了光敏剂探针分子铂八乙基卟啉(PtOEP)三重态吸收光谱的精确表征。在此基础上,本文测试了PtOEP在不同探测光波长下的光声泵浦成像效果,证实了其在770 nm的三重态吸收峰值处具有最佳的图像信噪比。仿体成像结果表明,经探测光波长优化后的光声泵浦成像系统可以有效去除血红蛋白和墨水等强背景信号干扰,实现对PtOEP分子的高特异性去背景成像。另外,通过改变泵浦-探测光延时,拟合获得实验体系下PtOEP样品激发态寿命为1.87 μs,拟合优度R2达0.9879。本研究构建的从探针材料光物理机制表征到宏观成像系统优化的完整策略,有望推动光声泵浦成像在生物医学中的应用。


17 October 2026 in Acta Physica Sinica
Verified
Journal Article
Open access
PDF file
ZZZhang Zhanjun
Zhang Zhanjun
HXHuang Xing
Huang Xing
GJGuo Jianfeng
Guo Jianfeng
BWBo Wang
Bo Wang
相对于传统的光声成像,光声泵浦成像可以通过光敏剂分子的瞬态吸收效应,有效的排除组织中血液等强内源性吸收物质的影响,实现目标分子的有效探测。然而,现有的光声泵浦成像多基于亚甲基蓝(Methylene Blue,MB)等短三重态寿命光敏分子,只能采用相对较低的泵浦-探测延迟。由于泵浦光格鲁尼森效应的影响,强吸收背景组织也会产生微小的瞬态热弛豫差分信号,限制了其成像特异性的提高。为此,本文基于高分子刚性限域效应,通过固相聚乙烯醇的致密氢键网络有效抑制了MB分子的非辐射弛豫,成功延长了其三重态寿命,并在此基础上展开光声泵浦成像研究。结果表明,相比于传统的游离MB,经过该固相微环境调制的MB光敏剂分子可以使得光声泵浦成像的最优泵浦-探测延迟时间提高4.17倍,从而在相当的吸收水平条件下,使光声泵浦成像的特异性提高2.99倍。本研究揭示了光敏剂微环境刚性调控对光声泵浦成像的影响,对高特异性光声泵浦成像方法的开发具有重要的指导意义。