Josep Sanahuja Blasco

Dr. Josep Sanahuja Blasco

H Clinic
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2023 in HPB
Verified
Journal Article
Closed access
JBJosep Sanahuja Blasco
Josep Sanahuja Blasco
EREnric Reverter
Enric Reverter
ÁRÁngel Ruiz
Ángel Ruiz
DSDenise Saenz
Denise Saenz
JMJulia Martínez-Ocón
Julia Martínez-Ocón
ABAnnabel Blasi
Annabel Blasi

8 June 2023 in Cancers
Verified
Journal Article
Open access
PDF file
AAAlejandra Garrido Atienza
Alejandra Garrido Atienza
MGMarta Guardiola
Marta Guardiola
LNLuz María Neira
Luz María Neira
RSRoberto Sont
Roberto Sont
HCHenry Córdova
Henry Córdova
GFGloria Fernández-Esparrach
Gloria Fernández-Esparrach
Background and Aims: Colonoscopy is currently the most effective way of detecting colorectal cancer and removing polyps, but it has some drawbacks and can miss up to 22% of polyps. Microwave imaging has the potential to provide a 360° view of the colon and addresses some of the limitations of conventional colonoscopy. This study evaluates the feasibility of a microwave-based colonoscopy in an in vivo porcine model. Methods: A prototype device with microwave antennas attached to a conventional endoscope was tested on four healthy pigs and three gene-targeted pigs with mutations in the adenomatous polyposis coli gene. The first four animals were used to evaluate safety and maneuverability and compatibility with endoscopic tools. The ability to detect polyps was tested in a series of three gene-targeted pigs. Results: the microwave-based device did not affect endoscopic vision or cause any adverse events such as deep mural injuries. The microwave system was stable during the procedures, and the detection algorithm showed a maximum detection signal for adenomas compared with healthy mucosa. Conclusions: Microwave-based colonoscopy is feasible and safe in a preclinical model, and it has the potential to improve polyp detection. Further investigations are required to assess the device’s efficacy in humans.

22 March 2025 in Cancers
Verified
Journal Article
Open access
PDF file
OOOswaldo Ortiz
Oswaldo Ortiz
OSOriol Sendino
Oriol Sendino
SRSilvia Rivadulla
Silvia Rivadulla
AAAlejandra Garrido Atienza
Alejandra Garrido Atienza
LNLuz María Neira
Luz María Neira
GFGloria Fernández-Esparrach
Gloria Fernández-Esparrach
Background/Objectives: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims to evaluate, for the first time, the feasibility, safety and performance of microwave-based colonoscopy for diagnosis of polyps in real-time explorations in humans. Methods: This was a single-center, prospective, observational study. Patients referred for diagnostic colonoscopy were explored with a device with microwave antennas which was attached to the tip of a standard colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for the detection of polyps. Secondary outcomes were the following: patients’ subjective feedback, procedural time and perception of difficulty according to the endoscopist. Results: Fifteen patients were enrolled. Cecal intubation rate was 100%, with a mean time of 12.7 ± 4.9 min (range 4–22). Use of the device did not affect the endoscopic image, and polypectomy was successfully performed in all cases. In on scale from zero (not difficult) to four (very difficult), the maneuverability during the insertion was considered ≤2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) reported no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential to detect polyps in real colonoscopies.

7 August 2021 in Cancers
Verified
Journal Article
Open access
PDF file
AHAmelia Hessheimer
Amelia Hessheimer
JLJordi Vengohechea Llorens
Jordi Vengohechea Llorens
LMLilia Martínez de la Maza
Lilia Martínez de la Maza
JLJavier Muñoz Luque
Javier Muñoz Luque
MVMarina Vendrell
Marina Vendrell
CFConstantino Fondevila
Constantino Fondevila
Liver resection treats primary and secondary liver tumors, though clinical applicability is limited by the remnant liver mass and quality. Herein, major hepatic resections were performed in pigs to define changes associated with sufficient and insufficient remnants and improve liver-specific outcomes with somatostatin therapy. Three experimental groups were performed: 75% hepatectomy (75H), 90% hepatectomy (90H), and 90% hepatectomy + somatostatin (90H + SST). Animals were followed for 24 h (N = 6) and 5 d (N = 6). After hepatectomy, portal pressure gradient was higher in 90H versus 75H and 90H + SST (8 (3–13) mmHg vs. 4 (2–6) mmHg and 4 (2–6) mmHg, respectively, p < 0.001). After 24 h, changes were observed in 90H associated with stellate cell activation and collapse of sinusoidal lumen. Collagen chain type 1 alpha 1 mRNA expression was higher, extracellular matrix width less, and percentage of collagen-staining areas greater at 24 h in 90H versus 75H and 90H + SST. After 5 d, remnant liver mass was higher in 75H and 90H + SST versus 90H, and Ki-67 immunostaining was higher in 90H + SST versus 75H and 90H. As well, more TUNEL-staining cells were observed in 90H versus 75H and 90H + SST at 5 d. Perioperative somatostatin modified portal pressure, injury, apoptosis, and stellate cell activation, stemming changes related to hepatic fibrogenesis seen in liver remnants not receiving treatment.

25 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
OOOswaldo Ortiz
Oswaldo Ortiz
OSOriol Sendino
Oriol Sendino
SRSilvia Rivadulla
Silvia Rivadulla
AAAlejandra Garrido Atienza
Alejandra Garrido Atienza
LNLuz María Neira
Luz María Neira
GFGloria Fernández-Esparrach
Gloria Fernández-Esparrach
Background/Objectives: Microwave imaging can obtain anatomical and functional images of the colon and has demonstrated to detect polyps based on their dielectric properties. This study aims to evaluate the feasibility, safety and performance of micro-wave-based colonoscopy for diagnosis of polyps in humans. Methods: single-center, prospective, observational study. Patients referred for elective outpatient diagnostic co-lonoscopy were included. A device provided with microwave antennas was attached to the tip of a conventional colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for detection of polyps. Secondary outcomes were: patients’ subjective feedback, procedural time and perception of difficulty by the endoscopist. Results: 15 patients were enrolled. Cecal intubation rate was 100% with a mean time of 12.7±4.9 min (range 4-22). Use of the device did not affect the endoscopic image and polypectomy was successfully performed in all cases. In a scale from 0 (not difficult) to 4 (very difficult), the maneuverability during the insertion was considered < 2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) referred no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential of detecting polyps.

5 March 2026 in JHEP Reports
Verified
Journal Article
Open access
JLJordi Vengohechea Llorens
Jordi Vengohechea Llorens
AHAmelia Hessheimer
Amelia Hessheimer
JMJavier Muñoz
Javier Muñoz
JAJoaquim Albiol
Joaquim Albiol
MVMarina Vendrell
Marina Vendrell
CFConstantino Fondevila
Constantino Fondevila
Performing ex situ normothermic machine perfusion (NMP) for ≥24 h represents an opportunity to evaluate and treat livers, but is limited by the lack of support from relevant extrahepatic organs. Incorporation of systems of renal replacement therapy, including hemodiafiltration (HDF), appears useful in this regard during prolonged ex situ liver NMP. This study aimed to demonstrate the impact and benefits associated with incorporation of continuous HDF during 24-h ex situ NMP in a relevant preclinical model, including transplantation and post-transplant follow-up. Porcine livers (n = 28) underwent 24-h ex situ NMP with either partial perfusate exchange at 12 h and no HDF (NHDF, n = 11) or HDF initiated 2 h after NMP start (n = 17). Biochemical, histological, endothelial, and metabolomic parameters were assessed. A subset of grafts undergoing NMP + HDF (n = 8) were transplanted into recipients. Incorporation of HDF during NMP maintained stable pH and electrolyte levels, effectively preventing hypernatremia, hypochloremia, and hypocalcemia developing without HDF. HDF cleared metabolic wastes (e.g. urea) and inflammatory cytokines (IL-1B, IL-2, IL-6, IL-8, and IL-18), resulting in reduced injury and oxidative stress markers after 24 h (Suzuki score 0.8 ± 0.4 HDF vs. 2.7 ± 1.3 NHDF, p <0.001). Vasoprotective endothelial response mechanisms, including KLF2 and eNOS gene and protein expression, were upregulated, whereas stellate cell activation and sinusoidal contraction were reduced among HDF-treated grafts. HDF reduced metabolomic alterations arising in livers during 24-h NMP, and adequate graft maintenance using NMP + HDF was demonstrated by full functional and metabolic recovery during post-transplant follow-up. Continuous HDF promotes a more physiological biochemical and metabolic environment, reduces inflammation and oxidative stress, and preserves homeostatic endothelial response mechanisms in livers undergoing 24-h ex situ NMP, facilitating successful transplantation in a complex preclinical model. In this preclinical study, livers were normothermically perfused for 24 h ex situ, both with and without continuous HDF. Incorporation of HDF offered relevant improvements in numerous on-device measures, including the maintenance of physiological biochemical parameters; removal of injurious metabolic wastes; and improvement of injury and stress responses in parenchymal and nonparenchymal cells. A subset of livers were successfully transplanted and demonstrated full functional and metabolic recovery during follow-up. These findings indicate that advanced renal replacement therapies, such as HDF, are a key aspect of improving and prolonging ex situ normothermic liver perfusion, although there is ongoing need to develop more physiological metabolic support protocols for livers while on such devices.