Sangamanatha Ankmnal Veeranna

Dr. Sangamanatha Ankmnal Veeranna

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
SVSangamanatha Ankmnal Veeranna
Sangamanatha Ankmnal Veeranna
CAChris Allan
Chris Allan
PAPrudence Allen
Prudence Allen

13 December 2021 in Audiology Research
Verified
Journal Article
Open access
PDF file
JSJordana Costa Soares
Jordana Costa Soares
SVSangamanatha Ankmnal Veeranna
Sangamanatha Ankmnal Veeranna
VPVijay Parsa
Vijay Parsa
CAChris Allan
Chris Allan
WLWinnie Ly
Winnie Ly
PAPrudence Allen
Prudence Allen
Many hearing difficulties can be explained as a loss of audibility, a problem easily detected and treated using standard audiological procedures. Yet, hearing can be much poorer (or more impaired) than audibility predicts because of deficits in the suprathreshold mechanisms that encode the rapidly changing, spectral, temporal, and binaural aspects of the sound. The ability to evaluate these mechanisms requires well-defined stimuli and strict adherence to rigorous psychometric principles. This project reports on the comparison between a laboratory-based and a mobile system’s results for psychoacoustic assessment in adult listeners with normal hearing. A description of both systems employed is provided. Psychoacoustic tests include frequency discrimination, amplitude modulation detection, binaural encoding, and temporal gap detection. Results reported by the mobile system were not significantly different from those collected with the laboratory-based system for most of the tests and were consistent with those reported in the literature. The mobile system has the potential to be a feasible option for the assessment of suprathreshold auditory encoding abilities.

30 March 2025 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
HWHasitha Wimalarathna
Hasitha Wimalarathna
PYPatricia LeeAnn Youngblood
Patricia LeeAnn Youngblood
CPCaroline Parker
Caroline Parker
CMCharles G. Marx
Charles G. Marx
SVSangamanatha Ankmnal Veeranna
Sangamanatha Ankmnal Veeranna

1 March 2026 in Journal of the American Academy of Audiology
Verified
Journal Article
Closed access
JCJennifer Chapman
Jennifer Chapman
TWTyler Weaver
Tyler Weaver
SVSangamanatha Ankmnal Veeranna
Sangamanatha Ankmnal Veeranna
CMCharles Marx
Charles Marx
Background: The auditory brainstem response (ABR) test is used to estimate hearing thresholds and for neurodiagnostic purposes. ABRs can be recorded for traditional stimuli such as broadband clicks and frequency-specific tone bursts (0.5, 1, 2, and 4 kHz). Recently, chirp stimuli (broadband and narrowband chirps [0.5, 1, 2, and 4 kHz]) have been recommended to be used to record ABRs. Purpose: There is a lack of comparative studies of ABR latency, amplitude, and thresholds obtained from these systems for both traditional and chirp stimuli. Research Design: Repeated measure design. Study Sample: Fifteen adults whose hearing thresholds were ≤25 dB HL participated in this study. Data Collection and Analysis: The Interacoustics Eclipse-25 (EP-25), the Intelligent Hearing System (IHS), and the Vivosonic Integrity V500 systems were used. Peak-to-peak voltage was examined for traditional and chirp stimuli across all three systems. Behavioral and ABR thresholds were obtained for all stimuli. Also, peak V latencies and peak-to-peak amplitudes for all stimuli recorded at 80 dBnHL were examined. Results: Peak-to-peak voltage differed between systems, especially for chirp stimuli. The EP-25 and the IHS systems showed significantly lower behavioral thresholds for some chirp stimuli compared with traditional, comparable stimuli, whereas the Integrity V500 system showed significantly lower behavioral thresholds for broadband click and 4-kHz tone burst stimuli compared with comparable chirp stimuli. Significant differences in behavioral thresholds between systems were observed. The EP-25 (broadband chirp, 1-, 2-, and 4-kHz narrowband chirp) and the IHS (2-kHz narrowband chirp) showed significantly lower ABR thresholds for comparable stimuli, whereas the Integrity V500 system showed lower ABR thresholds for broadband click and 0.5-kHz tone burst stimuli compared with comparable chirp stimuli. ABR thresholds for 2-kHz tone burst and 0.5- and 2-kHz narrowband chirp stimuli were significantly different between systems. The peak V latencies of the IHS system were significantly longer for most of the stimuli compared with other systems. The Integrity V500 system showed significantly lower peak-to-peak amplitudes of peak V for most of the stimuli when compared with other systems. Conclusions: The ABR latencies, amplitudes, and thresholds may differ between ABR recording systems, and clinicians should be aware of these differences to avoid misdiagnosis. Clinical Relevance Statement: The differences in ABR latencies, amplitudes, and thresholds between systems may lead to inconsistencies in diagnostic accuracy. Audiologists should use system-specific normative data.

10 June 2025 in Perspectives of the Asha Special Interest Groups
Verified
Journal Article
Closed access
JCJennifer Candace-Ann Chapman
Jennifer Candace-Ann Chapman
SVSangamanatha Ankmnal Veeranna
Sangamanatha Ankmnal Veeranna
CMCharles Gordon Marx
Charles Gordon Marx
Purpose: The goal of this study is to examine auditory brainstem responses (ABRs) recorded for click and 8-kHz tone bursts (TBs) from normal-hearing infants and adults using a clinical auditory-evoked potential system. Method: Infants ( n = 34) and adults ( n = 10) with normal hearing participated in this study. ABRs for click stimuli and 8-kHz TBs were recorded at 70 dB nHL. ABR thresholds for 8-kHz TBs were obtained from both groups. In addition, behavioral thresholds for the 8-kHz TB stimulus were obtained from adults. Given that adults can participate in traditional behavioral testing, their data were included to demonstrate a correlation between behavioral thresholds for 8-kHz TB and electrophysiological thresholds for the same stimulus. Results: Peak I latency of the ABR for both click and 8-kHz TBs at 70 dB nHL were similar between adults and infants. Latencies of Peaks III and V of the ABR for both click and 8-kHz TBs were significantly prolonged in infants when compared to adults. Infants' ABR thresholds for 8 kHz were significantly elevated when compared to adults. Conclusion: The ABR for 8-kHz TB stimuli is not adultlike in newborn infants and this could be due to immature synaptic and axonal processing.

25 May 2026 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Open access
SVSangamanatha Ankmnal Veeranna
Sangamanatha Ankmnal Veeranna
CMCharles Gordon Marx
Charles Gordon Marx
Recent studies have reported that COVID-19 and its complications during pregnancy are not a risk for hearing loss. However, there is limited research on examining auditory brainstem response (ABR) latencies in infants whose mothers had COVID-19 during pregnancy. Hence, in this study, ABRs were recorded using condensation and rarefaction click polarities, as well as for CE-Chirp® stimuli, in infants whose mothers had COVID-19 during pregnancy and those whose mothers did not. In total, 27 infants whose mothers had COVID-19 during pregnancy and 32 infants whose mothers did not report COVID-19 during pregnancy participated in this study. Distortion product otoacoustic emissions (DPOAEs) were recorded. ABRs (at 70 dB nHL) for the click stimulus were recorded using condensation and rarefaction polarities. Whereas the ABRs for the CE-Chirp® stimuli were recorded only for rarefaction polarity. Absolute peak latencies (I, III, and V), I-V interpeak intervals, peak-to-peak amplitudes (I and V), and amplitude ratios (V/I) were examined. DPOAEs were similar between groups. ABR analyses showed no differences in peak I latencies between groups, but absolute latencies of peak III and V and I-V interpeak intervals for both condensation and rarefaction click polarities were significantly different between groups. Peak I amplitudes for both click polarities were similar between groups, but peak V amplitudes were significantly smaller in infants of mothers with COVID-19 during pregnancy. Peak I latencies of CE-Chirp® evoked ABRs were similar between groups, but latencies of III and V and I-V interpeak intervals were significantly prolonged in infants of mothers with COVID-19 during pregnancy, compared to those without. ABRs were atypical, regardless of the stimulus polarities or type in infants whose mothers had COVID-19 during pregnancy. Along with threshold assessment, the audiologist should prioritize evaluating ABRs recorded at higher intensity levels.