Volume-filling ratio of the working fluid has a predominant effect on the system performance of a closed two-phase solar water-heating (SWH) system. To study this effect, a prototype of a loop thermosyphon SWH system, which uses remolded flat-plate solar collector as the evaporator and the coil pipe in the water tank as the condenser, was set up. A set of long-term outdoor experiments under 10%, 20%, 30%, 50%, and 70% volume-filling ratios were conducted in this paper. R600a was used as working fluid. Loop thermosyphon solar collector thermal performance and system thermal performance under different volume-filling ratios, including the temperature distribution of loop thermosyphon evaporator, were presented. It is shown that the loop thermosyphon solar collector and the system had a better thermal performance than the conventional ones under 30% and 50% volume-filling ratio, and the loop thermosyphon evaporator had an even temperature distribution when the volume-filling ratio was higher than 30%. The optimum volume filing ratio lies in between 30% and 50% of the whole system volume.
Based on the typical meteorological year data of Shanghai city, annual performances of solar water heating (SWH) system and photovoltaic/thermal (PV/T) system are comparatively analyzed under three different cases. The results show that when only solar energy is used, the effective day number of SWH system is more than PV/T system under the same case every month; for the PV/T system, heat loss at the nighttime dissipates most of the absorbed solar energy under the continuous heating mode considering the nighttime heat loss case; initial water temperature determines system electric efficiency. On the whole, PV/T system offers competitive performance only under the auxiliary heating mode, no matter from the points of primary efficiency and static payback period.
27 February 2017 in International Journal of Low-Carbon Technologies
Wickless loop thermosyphon solar water heating (LT-SWH) systems, which working under the passive and active cycle modes, were designed and experimental setup, systems’ performance were comparative studied. The results showed that pump made the active cycle system overcharged, a small hydraulic head was observed most of time; because of that, there was a worse photothermal performance under the active cycle mode, no matter in the comparison of the instantaneous photothermal efficiency or the collector and system performance linear fitting; at the same time, there was also a worse isothermality of the solar evaporator under the active cycle mode.