Dezhi Wu

Dr. Dezhi Wu

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
ZXZhenjin Xu
Zhenjin Xu
DWDezhi Wu
Dezhi Wu
ZCZhiwen Chen
Zhiwen Chen
ZWZhongbao Wang
Zhongbao Wang
CCCong Cao
Cong Cao
DSDaoheng Sun
Daoheng Sun
The tactile pressure sensor is of great significance in flexible electronics, but sensitivity customization over the required working range with high linearity still remains a critical challenge. Despite numerous efforts to achieve high sensitivity and a wide working range, most sensitive microstructures tend to be obtained only by inverting naturally existing templates without rational design based on fundamental contact principles or models for piezoresistive pressure sensors. Here, a positive design strategy with a hyperelastic model and a Hertzian contact model for comparison was proposed to develop a flexible pressure sensor with highly customizable linear sensitivity and linearity, in which the microstructure distribution was precalculated according to the desired requirement prior to fabrication. As a proof of concept, three flexible pressure sensors exhibited sensitivities of 0.7, 1.0, and 1.3 kPa−1 over a linear region of up to 200 kPa, with a low sensitivity error (<5%) and high linearity (~0.99), as expected. Based on the superior electromechanical performance of these sensors, potential applications in physiological signal recognition are demonstrated as well, and such a strategy could shed more light on demand-oriented scenarios, including designable working ranges and linear sensitivity for next-generation wearable devices.

4 May 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
DWDezhi Wu
Dezhi Wu
LDLei Deng
Lei Deng
YSYu Sun
Yu Sun
KTKwok Siong Teh
Kwok Siong Teh
CSChuan Shi
Chuan Shi
LLLiwei Lin
Liwei Lin
Composite membranes have been fabricated made of ultrafine PVDF fibersviaa tip-induced electrospinning (TIE) process and Al2O3nanoparticlesviaa dip-coating process.

29 April 2017 in Polymers
Verified
Journal Article
Open access
PDF file
CSChuan Shi
Chuan Shi
JDJianhui Dai
Jianhui Dai
CLChao Li
Chao Li
JZJinbao Zhao
Jinbao Zhao
LPLongqing Peng
Longqing Peng
JZJinbao Zhao
Jinbao Zhao
In this work, the ceramic coating separator (CCS-CS) prepared with polyethylene (PE) separator, Al2O3 inorganic particles, carboxymethyl cellulose sodium (CMC) and styrene-butadiene rubber (SBR) mix binders is further modified by coating with a thin polydopamine (PDA) layer through a simple chemical deposition method. Compared with the bare ceramic coating separator, the PDA-modified CCS-CS (CCS-CS-PDA) exhibits excellent thermal stability, which shows no thermal shrinkage after storing at 200 °C for 30 min. Compared with the PE separator, both the uptake and wettability with the electrolyte and water of CCS-CS-PDA are improved significantly. Meanwhile, when saturated with liquid electrolyte, the CCS-CS-PDA also shows enabled high ionic conductance. Furthermore, the test of the electrochemical impedances changing with the temperatures suggests that only the PE separator exhibits no thermal shutdown behaviors, and the CCS-CS separator only has a shutdown temperature range from 138 to 160 °C, while the CCS-CS-PDA shows a shutdown temperature range from 138 to more than 200 °C. The cells prepared with the CCS-CS-PDA also show stable repeated cycling performance and good rate capacity at room temperature.

1 April 2022 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
YZYang Zhao
Yang Zhao
ZMZiyang Mei
Ziyang Mei
XLXiaoxiao Luo
Xiaoxiao Luo
JMJingsong Mao
Jingsong Mao
QZQingliang Zhao
Qingliang Zhao
DWDezhi Wu
Dezhi Wu
Remote vascular interventional surgery robotics: a literature review Yang Zhao, Ziyang Mei, Xiaoxiao Luo, Jingsong Mao, Qingliang Zhao, Gang Liu, Dezhi Wu

20 April 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
ZCZhuo Chen
Zhuo Chen
YZYang Zhang
Yang Zhang
BZBin Zhu
Bin Zhu
YWYigen Wu
Yigen Wu
XDXiaohui Du
Xiaohui Du
DWDezhi Wu
Dezhi Wu

13 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
DWDezhi Wu
Dezhi Wu
QPQianqian Peng
Qianqian Peng
SWShan Wu
Shan Wu
GWGuangshun Wang
Guangshun Wang
LDLei Deng
Lei Deng
LLLiwei Lin
Liwei Lin
Ammonia gas sensors are very essential in many industries and everyday life. However, their complicated fabrication process, severe environmental fabrication requirements and desorption of residual ammonia molecules result in high cost and hinder their market acceptance. Here, laser direct writing is used to fabricate three parallel porous 3D graphene lines on a polyimide (PI) tape to simply construct an ammonia gas sensor. The middle one works as an ammonia sensing element and the other two on both sides work as heaters to improve the desorption performance of the sensing element to ammonia gas molecules. The graphene lines were characterized by scanning electron microscopy and Raman spectroscopy. The response and recovery time of the sensor without heating are 214 s and 222 s with a sensitivity of 0.087% ppm−1 for sensing 75 ppm ammonia gas, respectively. The experimental results prove that under the optimized heating temperature of about 70 °C the heaters successfully help implement complete desorption of residual NH3 showing a good sensitivity and cyclic stability.