Guided wave inspection has proven to be a very effective method for the rapid inspection of large structures. The fundamental shear horizontal (SH) wave mode in plates and the torsional mode in pipe-like structures are especially useful because of their non-dispersive character. Guided waves can be generated by either piezoelectric transducers or electro- magnetic acoustic transducers (EMATs), and EMATs can be based on either the Lorentz force or magnetostriction. Several EMAT configurations can be used to produce SH waves, the most common being Lorentz-force periodic permanent magnet and magnetostrictive EMATs, the latter being directly applied on the sample or with a bonded strip of highly magnetostrictive material on the plate. This paper compares the performance of these solutions on steel structures. To quantitatively assess the wave amplitude produced by different probes, a finite element model of the elementary transducers has been developed. The results of the model are experimentally validated and the simulations are further used to study the dependence of ultrasonic wave amplitude on key design parameters. The analysis shows that magnetostrictive EMATs directly applied on mild steel plates have comparatively poor performance that is dependent on the precise magneto-mechanical properties of the test object. Periodic permanent magnet EMATs generate intermediate wave amplitudes and are noncontact and insensitive to the variations in properties seen across typical steels. Large signal amplitudes can be achieved with magnetostrictive EMATs with a layer of highly magnetostrictive material attached between the transducer and the plate, but this compromises the noncontact nature of the transducer.
17 January 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Conventional ultrasonic transducers cannot withstand high temperatures for two main reasons: the piezoelectric elements within them depolarize, and differential thermal expansion of the different materials within a transducer causes them to fail. In this paper, the design of a high-temperature ultrasonic thickness gauge that bypasses these problems is described. The system uses a waveguide to isolate the vulnerable transducer and piezoelectric elements from the high-temperature measurement zone. Use of thin and long waveguides of rectangular cross section allows large temperature gradients to be sustained over short distances without the need for additional cooling equipment. The main problems that had to be addressed were the transmission and reception of ultrasonic waves into and from the testpiece that the waveguides are coupled to, and optimization of the wave propagation along the waveguide itself. It was found that anti-plane shear loading performs best at transmitting and receiving from the surface of a component that is to be inspected. Therefore, a nondispersive guided wave mode in large-aspect-ratio rectangular strips was employed to transmit the anti-plane shear loading from the transducer to the measurement zone. Different joining methods to attach the waveguides to the component were investigated and experiments showed that clamping the waveguides to the component surface gave the best results. The thickness of different plate samples was consistently measured to within less than 0.1 mm. Performance at high temperatures was tested in a furnace at 730°C for 4 weeks without signal degradation. Thicknesses in the range of 3 to 25 mm could be monitored using Hanning windowed tonebursts with 2 MHz center frequency.
In the food industry and other industries, rheological measurements and determination of particle sizes in suspensions and emulsions is of great importance for process and quality control. Current test cell based ultrasonic methods exist but are often inconvenient. An attractive alternative could be to insert a simple measurement “dipstick” into the fluid; this paper presents an initial study of the feasibility of using measurements of the velocity and attenuation of the quasi-Scholte mode on a plate to obtain the longitudinal velocity and attenuation of an embedding medium. The attenuation of the quasi-Scholte mode is caused by two mechanisms: shear leakage and attenuation due to the bulk longitudinal attenuation of the embedding material. In a calibration test the bulk longitudinal velocity and viscosity of glycerol were determined experimentally. Measurements agreed well with results from conventional methods and literature data. Quantitative results and an independent validation for honey, a very viscous fluid, are also presented. For Newtonian liquids like glycerol and honey, the shear leakage and longitudinal bulk attenuation are both related to viscosity. To demonstrate the sensitivity to nonviscous attenuation mechanisms, qualitative measurement results on fluids that mainly exhibit attenuation due to scattering are presented.
13 December 2010 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
The noncontact nature of electromagnetic acoustic transducers (EMATs) offers a series of advantages over traditional piezoelectric transducers, but these features are counter-balanced by their relatively low signal-to-noise ratio and their strong dependence on material properties such as electric conductivity, magnetic permeability, and magnetostriction. The implication is that full exploitation of EMATs needs detailed modeling of their operation. A finite element model, accounting for the main transduction mechanisms, has been developed to allow the optimization of the transducers. Magnetostriction is included and described through an analogy with piezoelectricity. The model is used to predict the performance of a simple EMAT: a single current-carrying wire, parallel to a bias magnetic field generating shear horizontal waves in a nickel plate close to it. The results are validated against experiments. The model is able to successfully predict the wave amplitude dependence on significant parameters: the static bias field, the driving current amplitude, and the excitation frequency. The comparison does not employ any arbitrary adjustable parameter; for the first time an absolute validation of a magnetostrictive EMAT model has been achieved. The results are satisfactory: the discrepancy between the numerical predictions and the measured values of wave amplitude per unit current is less than 20% over a 200 kHz frequency range. The study has also shown that magnetostrictive EMAT sensitivity is not only a function of the magnetostrictive properties, because the magnetic permeability also plays a significant role in the transduction mechanism, partly counterbalancing the magnetostrictive effects.
27 April 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
The main advantage of electromagnetic acoustic transducers (EMATs) over piezoelectric transducers is that no direct contact with the specimen under test is required. Therefore, EMATs can be used to test through coating layers. However, they produce weaker signals, and hence, their design has to be optimized. This paper focuses on the design of a Lorentz force shear wave EMAT and its application in thickness gaging; special emphasis is placed on the optimization of the design elements that correspond to the bias magnetic field of the EMAT. A configuration that consists of several magnets axisymmetrically arranged around a ferromagnetic core with like poles facing the core was found to give the best results. By using this configuration, magnetic flux densities in excess of 3 T were obtained in the surface of a specimen; the maximum value achieved by a single magnet under similar conditions is roughly 1.2 T. If the diameter of an EMAT ultrasonic aperture is 10 mm, the proposed configuration produces signals roughly 20 dB greater than a single magnet, while for a given overall EMAT volume, signals were greater than 3-6 dB. Linear and radial shear wave polarizations were also compared; a higher mode purity and signal intensity were obtained with the linear polarization.