Sleep apnea (SA) is associated with cardiovascular diseases and is highly prevalent in patients with pacemakers (PMs). To validate a transthoracic impedance sensor with an advanced algorithm (sleep apnea monitoring) for identifying severe SA. Patients with indications for PM (VVI/DDD) were enrolled regardless of symptoms suggesting SA. Severe SA diagnosis was acknowledged when the full polysomnography gave an apnea-hypopnea index (PSG-AHI) of ≥30 events/h. The PSG-AHI was compared with the respiratory disturbance index evaluated by the SAM algorithm (SAM-RDI) compiled from the device during the same diagnosis night, and the performance of the device and the SAM algorithm was calculated to identify patients with severe SA. The agreement between methods was assessed by using Bland and Altman statistics. Forty patients (mean age 73.8 ± 19.1 years; 67.5% men; body mass index 27.7 ± 4.4 kg/m(2)) were included. Severe SA was diagnosed by PSG in 56% of the patients. We did not retrieve SAM-RDI data in 14% of the patients. An optimal cutoff value for the SAM-RDI at 20 events/h was obtained by a receiver operator characteristic curve analysis, which yielded a sensitivity of 88.9% (95% confidence interval [CI] 65.3%-98.6%), a positive predictive value of 88.9% (95% CI 65.3%-98.6%), and a specificity of 84.6% (95% CI 54.6%-98.1%) (n = 31). The Bland-Altman limits of agreement for PSG-AHI (in events per hour) were [-14.1 to 32.4]. The results suggest that an advanced algorithm using PM transthoracic impedance could be used to identify SA in patients with PMs outside the clinic or at home.
The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions’ experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs.
Aims To assess the level of pre-operative haemoglobin (HB) as a risk marker for morbidity and mortality in the early post-operative period of patients who underwent elective valve replacement. Methods and results Between January 1998 and March 2004, clinical and outcomes data were collected for the 201 patients who had elective valve replacement. For each gender, the criterion to choose the best cut-off point was that which achieved the maximum likelihood after several General Additive Model models performed in a Bootstrap procedure. The best cut-off point obtained for pre-operative HB was 12 g/dL. Overall peri-operative mortality (deaths occurring during hospital period or within 30 days) was 9.5%. After adjusting well-known independent pre-operative risk factors for operative mortality, pre-operative HB <12 g/dL was identified as an independent predictor for in-hospital mortality (OR, 3.23; 95% CI, 1.09–9.55; P=0.03). Also adjusting for EuroScore, pre-operative HB remained significant (OR, 3.64; 95% CI, 1.32–10.06; P=0.01). The same model was applied to post-operative morbidity, and pre-operative HB <12 g/dL was identified as an independent predictor with and without EuroScore (OR, 4.67; 95% CI, 2.03–10.71; P<0.001), (OR, 5.18; 95% CI, 2.18–12.3; P<0.001), respectively. Conclusion In patients undergoing elective valve replacement pre-operative HB <12 g/dL is a risk marker of in-hospital mortality and serious adverse outcomes.
MicroRNAs (miRNAs) have emerged as promising biomarkers of disease. Their potential use in clinical practice requires standardized protocols with very low miRNA concentrations, particularly in plasma samples. Here we tested the most appropriate method for miRNA quantification and validated the performance of a hybridization platform using lower amounts of starting RNA. miRNAs isolated from human plasma and from a reference sample were quantified using four platforms and profiled with hybridization arrays and RNA sequencing (RNA-seq). Our results indicate that the Infinite® 200 PRO Nanoquant and Nanodrop 2000 spectrophotometers magnified the miRNA concentration by detecting contaminants, proteins, and other forms of RNA. The Agilent 2100 Bioanalyzer PicoChip and SmallChip gave valuable information on RNA profile but were not a reliable quantification method for plasma samples. The Qubit® 2.0 Fluorometer provided the most accurate quantification of miRNA content, although RNA-seq confirmed that only ~58% of small RNAs in plasma are true miRNAs. On the other hand, reducing the starting RNA to 70% of the recommended amount for miRNA profiling with arrays yielded results comparable to those obtained with the full amount, whereas a 50% reduction did not. These findings provide important clues for miRNA determination in human plasma samples.