Purpose: The current standard in reconstructing defects of the orbital floor, by using the concept of mirroring, is time‐consuming and ignores the natural asymmetry of the skull. By using a statistical shape model (SSM), the reconstruction can be automatized and improved in accuracy. The present study aims to show the possibilities of the virtual reconstruction of artificial defects of the orbital floor using an SSM and its potentials for clinical implementation.Methods: Based on 131 unaffected CT scans of the midface, an SSM was created which contained the shape variability of the orbital floor. Nineteen midface CT scans, that were not included in the SSM, were manually segmented to establish ground truth (control group). Then artificial defects of larger and smaller sizes were created and reconstructed using SSM (Group I) and the gold standard of mirroring (Group II). Eventually, a comparison to the surface of the manual segmentation (control group) was performed.Results: The proposed method of reconstruction using an SSM leads to more precise reconstruction results, compared with the conventional method of mirroring. Whereas mirroring led to the reconstruction errors of 0.7 mm for small defects and 0.73 mm for large defects, reconstruction using SSM led to deviations of 0.26 mm (small defect) and, respectively, 0.34 mm (large defect).Conclusions: The presented approach is an effective and accurate method for reconstructing the orbital floor. In connection with modern computer‐aided design and manufacturing, individual patient‐specific implants could be produced according to SSM‐based reconstructions and could replace current methods using manual bending techniques. By acknowledging the natural asymmetry of the human skull, the SSM‐based approach achieves higher accuracy in reconstructing injured orbits.
22 April 2021 in Archives of orthopaedic and trauma surgery
Introduction: Currently there is no consensus how hindfoot alignment (HA) should be assessed in CBCT scans. The aim of this study is to investigate how the reliability is affected by the anatomical structures chosen for the measurement. Materials and methods: Datasets consisting of a Saltzman View (SV) and a CBCT of the same foot were acquired prospectively and independently assessed by five raters regarding HA. In SVs the HA was estimated as follows: transversal shift between tibial shaft axis and heel contact point (1); angle between tibial shaft axis and a tangent at the medial (2) or lateral (3) calcaneal wall. In CBCT the HA was estimated as follows: transversal shift between the centre of the talus and the heel contact point (4); angle between a perpendicular line and a tangent at the medial (5) or lateral (6) calcaneal wall; angle between the distal tibial surface and a tangent at the medial calcaneal wall (7). Intraclass correlation coefficients (ICC) were calculated to assess inter-rater reliability. A linear regression was performed to compare the different measurement regarding their correlation. Results: 32 patients were included in the study. The ICCs for the measurements 1–7 were as follows: (1) 0.924 [95% CI 0.876–0.959] (2) 0.533 [95% CI 0.377–0.692], (3) 0.553 [95% CI 0.399–0.708], (4) 0.930 [95% CI 0.866–0.962], (5) 0.00 [95% CI − 0.111 to 0.096], (6) 0.00 [95% CI − 0.103 to 0.111], (7) 0.152 [95% CI 0.027–0.330]. A linear regression between measurement 1 and 4 showed a correlation of 0.272 (p = 0.036). Conclusions: It could be shown that reliability of measuring HA depends on the investigated anatomical structure. Placing a tangent along the calcaneus (2, 3, 5, 6, 7) was shown to be unreliable, whereas determining the weight-bearing heel point (1, 4) appeared to be a reliable approach. The correlation of the measurement workflows is significant (p = 0.036), but too weak (0.272) to be used clinically.
Background: Computer Assisted Design and Computer Assisted Manufacturing (CAD/CAM) have revolutionized oncologic surgery of the head and neck. A multitude of benefits of this technique has been described, but there are only few reports of donor site comorbidity following CAD/CAM surgery. Methods: This study investigated comorbidity of the hip following deep circumflex iliac artery (DCIA) graft raising using CAD/CAM techniques. A cross-sectional examination was performed to determine range of motion, muscle strength and nerve disturbances. Furthermore, correlations between graft volume and skin incision length with postoperative donor site morbidity were assessed using Spearman's rank correlation, linear regression and analysis of variance (ANOVA). Results: Fifteen patients with a mean graft volume of 21.2 ± 5.7 cm3 and a mean incision length of 228.0 ± 30.0 mm were included. Patients reported of noticeable physical limitations in daily life activities (12.3 ± 11.9 weeks) and athletic activities (38.4 ± 40.0 weeks in mean) following surgery. Graft volume significantly correlated with the duration of the use of walking aids (R = 0.57; p = 0.033) and impairment in daily life activities (R = 0.65; p = 0.012). The length of the scar of the donor-site showed a statistically significant association with postoperative iliohypogastric nerve deficits (F = 4.4, p = 0.037). Patients with anaesthaesia of a peripheral cutaneous nerve had a larger mean scar length (280 ± 30.0 mm) than subjects with hypaesthesia (245 ± 10.1 mm) or no complaints (216 ± 27.7 mm). Conclusions: Despite sophisticated planning options in modern CAD/CAM surgery, comorbidity of the donor site following iliac graft harvesting is still a problem. This study is the first to investigate comorbidity after DCIA graft raising in a patient group treated exclusively with CAD/CAM techniques. The results indicate that a minimal invasive approach in terms of small graft volumes and small skin incisions could help to reduce postoperative symptomatology. Trial registration Retrospectively registered at the German Clinical Trials Register (DRKS-ID: DRKS00029066); registration date: 23/05/2022
Background: Complex bilateral midface fractures necessitate a surgically challenging procedure to preserve or restore the occlusion and the sensitive eye area. In this case control study, we aim to show the potential of a statistical shape model (SSM) for measuring the quality of the midface reconstruction, compared to the estimated preoperative situation. Methods: An individualized SSM was postoperatively registered on 19 reconstructed complex bilateral midface fractures. Using this SSM, the distances from the simulated preoperative situation to the postoperative positions of the fracture segments were calculated. The fracture lines for Le Fort II, Le Fort III, and NOE fractures were chosen as reference points for the distance measurements. Results: The SSM could be registered on all 19 complex bilateral midface fractures. All analyzed fractures showed a dorsal impaction (negative values) of the midface. Le Fort II fractures showed deviation values of –0.98 ± 4.6 mm, Le Fort III fractures showed values of –3.68 ± 3.6 mm, NOE type 2 fractures showed values of –0.25 ± 4.6 mm, and NOE type 1 fractures showed values of –0.25 ± 4.6 mm. Conclusions: The SSM can be used to measure the quality of the achieved reduction of complex bilateral midface fractures based on the estimated preoperative situation. Trial registration: DRKS00009719.
Background: This study evaluated the accuracy of computer‐assisted surgery (CAS)–drivenDCIA(deep circumflex iliac artery) flap mandibular reconstruction by traditional morphometric methods and geometric morphometric methods (GMM).Methods: Reconstruction accuracy was evaluated by measuring distances and angles between bilateral anatomical landmarks. Additionally, the average length of displacements vectors between landmarks was computed to evaluate factors assumed to influence reconstruction accuracy. Principal component analysis (PCA) was applied to unveil main modes of dislocation.Results: High reconstruction accuracy could be demonstrated for a sample consisting of 26 patients. The effect of the number of segments and length of defect on reconstruction accuracy were close to the commonly used significance threshold (p = 0.062/0.060). PCA demonstrated displacement to result mainly from sagittal and transversal shifts.Conclusions: CAS is a viable approach to achieve high accuracy in mandibular reconstruction and GMM can facilitate the evaluation of factors influencing reconstruction accuracy and unveil main modes of dislocation in this context.
Objectives/Hypothesis: The prevalence of tympanostomy tube surgery (TTS) in patients with a cleft deformity was investigated, in relation to cleft width and cleft type.Study Design: Retrospective review of medical health records.Methods: Retrospective review of medical health records. Seventy‐eight patients with non‐syndromic cleft deformity of the palate and/or alveolus and lip between 2003 and 2017 were investigated. All available medical documents were analyzed. The study group was divided into subgroups: 1) patients with isolated cleft palate (CP) and patients with a cleft palate with cleft lip and alveolus (CLP). 2) According to Veau's classification (I–IV), further subgroups were defined. Cleft width was measured using plaster cast models.Results: TTS was performed in 55% of the patients (n = 43). Considering Veau's classification, TTS was conducted as follows: Veau I 65.2% (n = 15/23), Veau II 55.0% (n = 11/20), Veau III 47.6% (n = 10/21), and Veau IV 50.0% (n = 7/14). Cleft classifications, maxillary arch width, and absolute/relative cleft width had no statistical impact on TTS occurrence. Although no significant correlation could be found, patients in our study group with CP (Veau I and II) underwent TTS more often (60.5%, n = 26/43) than patients with CPL (Veau III and IV; 48.6%, n = 17/35) during a three‐year follow‐up.Conclusion: None of the cleft characteristics examined had a significant impact on the proportion of patients who received TTS. Nevertheless, patients with lower Veau classification and CP received tympanostomy tubes more often. Therefore, otolaryngologists and pediatricians treating children with cleft palate should maintain a high level of suspicion for chronic middle ear effusion, even in patients with small clefts.Level of Evidence: 3 Laryngoscope, 131:E2764–E2769, 2021