Louisa O'Neill

Dr. Louisa O'Neill


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
OROrod Razeghi
Orod Razeghi
ISIain Sim
Iain Sim
CRCaroline H. Roney
Caroline H. Roney
RKRashed Karim
Rashed Karim
HCHenry Chubb
Henry Chubb
SNSteven Niederer
Steven Niederer
Background: Pathological atrial fibrosis is a major contributor to sustained atrial fibrillation. Currently, late gadolinium enhancement (LGE) scans provide the only noninvasive estimate of atrial fibrosis. However, widespread adoption of atrial LGE has been hindered partly by nonstandardized image processing techniques, which can be operator and algorithm dependent. Minimal validation and limited access to transparent software platforms have also exacerbated the problem. This study aims to estimate atrial fibrosis from cardiac magnetic resonance scans using a reproducible operator-independent fully automatic open-source end-to-end pipeline. Methods: A multilabel convolutional neural network was designed to accurately delineate atrial structures including the blood pool, pulmonary veins, and mitral valve. The output from the network removed the operator dependent steps in a reproducible pipeline and allowed for automated estimation of atrial fibrosis from LGE-cardiac magnetic resonance scans. The pipeline results were compared against manual fibrosis burdens, calculated using published thresholds: image intensity ratio 0.97, image intensity ratio 1.61, and mean blood pool signal +3.3 SD. Results: We validated our methods on a large 3-dimensional LGE-cardiac magnetic resonance data set from 207 labeled scans. Automatic atrial segmentation achieved a 91% Dice score, compared with the mutual agreement of 85% in Dice seen in the interobserver analysis of operators. Intraclass correlation coefficients of the automatic pipeline with manually generated results were excellent and better than or equal to interobserver correlations for all 3 thresholds: 0.94 versus 0.88, 0.99 versus 0.99, 0.99 versus 0.96 for image intensity ratio 0.97, image intensity ratio 1.61, and +3.3 SD thresholds, respectively. Automatic analysis required 3 minutes per case on a standard workstation. The network and the analysis software are publicly available. Conclusions: Our pipeline provides a fully automatic estimation of fibrosis burden from LGE-cardiac magnetic resonance scans that is comparable to manual analysis. This removes one key source of variability in the measurement of atrial fibrosis.

5 September 2019 in EP Europace
Verified
Journal Article
Open access
PDF file
LOLouisa O'Neill
Louisa O'Neill
RKRashed Karim
Rashed Karim
RMRahul K Mukherjee
Rahul K Mukherjee
JWJohn Whitaker
John Whitaker
ISIain Sim
Iain Sim
SWSteven E Williams
Steven E Williams
A point-by-point workflow for pulmonary vein isolation (PVI) targeting pre-defined Ablation Index values (a composite of contact force, time, and power) and minimizing interlesion distance may optimize the creation of contiguous ablation lesions whilst minimizing scar formation. We aimed to compare ablation scar formation in patients undergoing PVI using this workflow to patients undergoing a continuous catheter drag workflow. Post-ablation cardiovascular magnetic resonance imaging was performed in patients undergoing 1st-time PVI using a parameter-guided point-by-point workflow (n = 26). Total left atrial scar burden and the width and continuity of the pulmonary vein encirclement were determined on analysis of atrial late gadolinium enhancement sequences. Comparison was made with a cohort of patients (n = 20) undergoing PVI using continuous drag lesions. Mean post-ablation scar burden and scar width were significantly lower in the point-by-point group than in the control group (6.6 ± 6.8% vs. 9.6 ± 5.0%, P = 0.03 and 7.9 ± 3.6 mm vs. 10.7 ± 2.3 mm, P = 0.003). More complete bilateral pulmonary vein encirclements were seen in the point-by-point group (P = 0.038). All patients achieved acute PVI. Pulmonary vein isolation using a point-by-point workflow is feasible and results in a lower scar burden and scar width with more complete pulmonary vein encirclements than a conventional drag lesion approach.

26 September 2021 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
LOLouisa O'Neill
Louisa O'Neill
ISIain Sim
Iain Sim
DODaniel O’hare
Daniel O’hare
JWJohn Whitaker
John Whitaker
RMRahul K Mukherjee
Rahul K Mukherjee
SWSteven E Williams
Steven E Williams
Atrial septal defects (ASD) are associated with atrial arrhythmias, but the arrhythmia substrate in these patients is poorly defined. We hypothesized that bi-atrial fibrosis is present and that right atrial fibrosis is associated with atrial arrhythmias in ASD patients. We aimed to evaluate the extent of bi-atrial fibrosis in ASD patients and to investigate the relationships between bi-atrial fibrosis, atrial arrhythmias, shunt fraction, and age. Patients with uncorrected secundum ASDs (n = 36; 50.4 ± 13.6 years) underwent cardiac magnetic resonance imaging with atrial late gadolinium enhancement. Comparison was made to non-congenital heart disease patients (n = 36; 60.3 ± 10.5 years) with paroxysmal atrial fibrillation (AF). Cardiac magnetic resonance parameters associated with atrial arrhythmias were identified and the relationship between bi-atrial structure, age, and shunt fraction studied. Bi-atrial fibrosis burden was greater in ASD patients than paroxysmal AF patients (20.7 ± 14% vs. 10.1 ± 8.6% and 14.8 ± 8.5% vs. 8.6 ± 6.1% for right and left atria respectively, P = 0.001 for both). In ASD patients, right atrial fibrosis burden was greater in those with than without atrial arrhythmias (33.4 ± 18.7% vs. 16.8 ± 10.3%, P = 0.034). On receiver operating characteristic analysis, a right atrial fibrosis burden of 32% had a 92% specificity and 71% sensitivity for predicting the presence of atrial arrhythmias. Neither age nor shunt fraction was associated with bi-atrial fibrosis burden. Bi-atrial fibrosis burden is greater in ASD patients than non-congenital heart disease patients with paroxysmal AF. Right atrial fibrosis is associated with the presence of atrial arrhythmias in ASD patients. These findings highlight the importance of right atrial fibrosis to atrial arrhythmogenesis in ASD patients.

1 January 2019 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
JWJohn Whitaker
John Whitaker
RNRadhouene Neji
Radhouene Neji
NBNicholas Byrne
Nicholas Byrne
EPEsther Puyol-Antón
Esther Puyol-Antón
RMRahul K. Mukherjee
Rahul K. Mukherjee
SRSébastien Roujol
Sébastien Roujol
Ex-vivo cardiovascular magnetic resonance (CMR) imaging has played an important role in the validation of in-vivo CMR characterization of pathological processes. However, comparison between in-vivo and ex-vivo imaging remains challenging due to shape changes occurring between the two states, which may be non-uniform across the diseased heart. A novel two-step process to facilitate registration between ex-vivo and in-vivo CMR was developed and evaluated in a porcine model of chronic myocardial infarction (MI). Seven weeks after ischemia-reperfusion MI, 12 swine underwent in-vivo CMR imaging with late gadolinium enhancement followed by ex-vivo CMR 1 week later. Five animals comprised the control group, in which ex-vivo imaging was undertaken without any support in the LV cavity, 7 animals comprised the experimental group, in which a two-step registration optimization process was undertaken. The first step involved a heart specific flexible 3D printed scaffold generated from in-vivo CMR, which was used to maintain left ventricular (LV) shape during ex-vivo imaging. In the second step, a non-rigid co-registration algorithm was applied to align in-vivo and ex-vivo data. Tissue dimension changes between in-vivo and ex-vivo imaging were compared between the experimental and control group. In the experimental group, tissue compartment volumes and thickness were compared between in-vivo and ex-vivo data before and after non-rigid registration. The effectiveness of the alignment was assessed quantitatively using the DICE similarity coefficient. LV cavity volume changed more in the control group (ratio of cavity volume between ex-vivo and in-vivo imaging in control and experimental group 0.14 vs 0.56, p < 0.0001) and there was a significantly greater change in the short axis dimensions in the control group (ratio of short axis dimensions in control and experimental group 0.38 vs 0.79, p < 0.001). In the experimental group, prior to non-rigid co-registration the LV cavity contracted isotropically in the ex-vivo condition by less than 20% in each dimension. There was a significant proportional change in tissue thickness in the healthy myocardium (change = 29 ± 21%), but not in dense scar (change = − 2 ± 2%, p = 0.034). Following the non-rigid co-registration step of the process, the DICE similarity coefficients for the myocardium, LV cavity and scar were 0.93 (±0.02), 0.89 (±0.01) and 0.77 (±0.07) respectively and the myocardial tissue and LV cavity volumes had a ratio of 1.03 and 1.00 respectively. The pattern of the morphological changes seen between the in-vivo and the ex-vivo LV differs between scar and healthy myocardium. A 3D printed flexible scaffold based on the in-vivo shape of the LV cavity is an effective strategy to minimize morphological changes in the ex-vivo LV. The subsequent non-rigid registration step further improved the co-registration and local comparison between in-vivo and ex-vivo data.

2 August 2023 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
LOLouisa O'Neill
Louisa O'Neill
AAAlexandre Almorad
Alexandre Almorad
MHMilad El Haddad
Milad El Haddad
JWJean-Yves Wielandts
Jean-Yves Wielandts
KGKris Gillis
Kris Gillis
SKSebastien Knecht
Sebastien Knecht

22 April 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LOLouisa O'Neill
Louisa O'Neill
BBBenjamin De Becker
Benjamin De Becker
MSMaarten De Smet
Maarten De Smet
CFClara Francois
Clara Francois
RTRene Tavernier
Rene Tavernier
SKSebastien Knecht
Sebastien Knecht
The outcomes of persistent atrial fibrillation (AF) ablation are modest with various adjunctive strategies beyond pulmonary vein isolation (PVI) yielding largely disappointing results in randomised controlled trials. Linear ablation is a commonly employed adjunct strategy but is limited by difficulty in achieving durable bidirectional block, particularly at the mitral isthmus. Epicardial connections play a role in AF initiation and perpetuation. The ligament of Marshall has been implicated as a source of AF triggers and is known to harbour sympathetic and parasympathetic nerve fibres that contribute to AF perpetuation. Ethanol infusion into the Vein of Marshall, a remnant of the superior vena cava and key component of the ligament of Marshall, may eliminate these AF triggers and can facilitate the ease of obtaining durable mitral isthmus block. While early trials have demonstrated the potential of Vein of Marshall ‘ethanolisation’ to reduce arrhythmia recurrence after persistent AF ablation, further randomised trials are needed to fully determine the potential long-term outcome benefits afforded by this technique.