Murineanu Rodica

Dr. Murineanu Rodica

Universitatea "Ovidius" din Constanta, Facultatea de Medicina Dentara
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2025 in Medicina
Verified
Journal Article
Open access
PDF file
LILIANA SACHELARIELILIANA SACHELARIE
LILIANA SACHELARIE
CȘCorina-Laura Ștefănescu
Corina-Laura Ștefănescu
MRMurineanu Rodica
Murineanu Rodica
MGMircea Grigorian
Mircea Grigorian
AZAgripina Zaharia
Agripina Zaharia
Loredana Liliana HurjuiLoredana Liliana Hurjui
Loredana Liliana Hurjui
Background: Periodontal disease is a chronic inflammatory condition affecting the supporting tissues of the teeth. Early diagnosis is crucial for preventing severe complications. This study investigates and compares the utility of two salivary biomarkers, interleukin-1 beta (IL-1β) and matrix metalloproteinase-8 (MMP-8), in the early detection and staging of periodontal disease. Methods: This study included 189 patients, all of whom were evaluated both clinically and biologically. Each participant provided unstimulated saliva samples, which were analyzed using ELISA methods to quantify IL-1β and MMP-8 levels. Clinical periodontal data, including probing depth (3.9 ± 0.6 mm), clinical attachment loss (3.4 ± 0.6 mm), and Plaque Index (2.35 ± 0.55), were collected for all subjects. Biomarker concentrations were then correlated with these clinical parameters and with disease severity, classified according to the 2018 EFP/AAP criteria. Results: IL-1β levels (210 ± 95 pg/mL) were strongly associated with early gingival inflammation, while MMP-8 levels (185 ± 140 ng/mL) correlated with periodontal tissue destruction (p < 0.01). MMP-8 showed a higher sensitivity for diagnosing advanced stages (p = 0.002), whereas IL-1β was more effective in detecting early inflammatory changes (p = 0.01). Logistic regression identified MMP-8 as a significant predictor of advanced disease (coefficient 0.85, p < 0.001) and IL-1β as an indicator of early inflammation (coefficient 0.25, p = 0.02). Conclusions: Both biomarkers are valuable tools for the diagnosis and staging of periodontal disease. MMP-8 is relevant for identifying advanced cases, while IL-1β supports early detection. Their combined use may enhance diagnostic accuracy and guide personalized periodontal care.

11 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CPCristina Gabriela Puşcaşu
Cristina Gabriela Puşcaşu
CȘCorina-Laura Ștefănescu
Corina-Laura Ștefănescu
MRMurineanu Rodica
Murineanu Rodica
MGMircea Grigorian
Mircea Grigorian
PCPetcu Lucian Cristian
Petcu Lucian Cristian
RPRadu Andrei Pușcașu
Radu Andrei Pușcașu
Background: The possible histological changes in dental pulp in teeth of diabetic patients are important to be understood, as the clinician will consider the best treatment choice for those teeth, especially if they are affected by decay. The aim of this paper is to assess if there are effects of diabetes-associated hyperglycemia on the nervous and vascular system of the dental pulp. Methods: Twenty-three dental pulp specimens of patients aged 36–70 years old were analyzed. All patients had been diagnosed with type 2 diabetes for at least 5 years. Results: Most of the patients had poorly controlled hyperglycemia, deep caries, but no clinical signs of pulpitis. The histological aspects of pulp specimens included frequently seen inflammatory infiltrate, degeneration of the nerves, thickened blood vessel walls, pulp sclerosis and frequent pulp calcifications, and even small necrotic areas. Conclusion: The analyzed dental pulp specimens of carious teeth of type 2 diabetic patients show fibrotic transformation of the dental pulp, with the presence of calcifications, arteriosclerosis and inflammatory infiltrate. In this situation, the attitude of the dentist in pulp vitality preservation in the case of carious teeth of diabetic patients should be limited.

11 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CȘCorina-Laura Ștefănescu
Corina-Laura Ștefănescu
AZAgripina Zaharia
Agripina Zaharia
MRMurineanu Rodica
Murineanu Rodica
CPCristina Gabriela Puşcaşu
Cristina Gabriela Puşcaşu
LILIANA SACHELARIELILIANA SACHELARIE
LILIANA SACHELARIE
MGMircea Grigorian
Mircea Grigorian
In the case of old mobile denture wearers, one of the main problems is related to the dentures’ retention and insufficient stability. Our goal was to improve support and stability using a different type of final impression, with different types of impression materials. In this study we chose a number of three complete edentulous patients who presented for complete oral rehabilitation. They were wearing full acrylic dentures with poor support and stability. Complete examination revealed the presence of the flabby ridge. The impression methods for the prosthetic fields with a flabby ridge differ from the classical method by using techniques that involve the use of at least two impression materials with fluid consistency to record all the details of the prosthetic fields in the final impression, this being done in two steps; the impression of the flabby ridge areas must be done without pressure, in its resting position. The impression methods we applied led to the expected results, and the dentures succeeded in offering the patient the desired functional comfort. Using fluid impression material for the flabby ridge in a resting position, and a fenestrated custom tray, offered a good quality in adaptation, maintenance and stability of the final dentures.

30 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CȘCorina-Laura Ștefănescu
Corina-Laura Ștefănescu
LNLavinia Neculai-Cândea
Lavinia Neculai-Cândea
MPMarius Florentin Popa
Marius Florentin Popa
AZAgripina Zaharia
Agripina Zaharia
MRMurineanu Rodica
Murineanu Rodica
VDVlad Danila
Vlad Danila
(1) Background: the present study continues previous research on new marking techniques by using intelligent materials, NFC-tags (Near Field Communication tags) and Aerogel. They prevent the loss of information over time for cadavers of unknown identities in various stages of destruction or unknown living victims, as well as missing persons who have lost or are concealing their identity. (2) Methods: this study consisted of a technological and an experimental stage. In the technological stage, two different sizes were used: round (Ø 1 cm, 0.1 mm thickness, 0.1 g weight) and square (5/5/0.1 mm), both with a 140 byte memory and high-temperature resistance (at max. 200 °C), (by the classical producing technology). After loading the identification information on the NFC-tags, they were embedded (either alone or protected by Aerogel) in the sample dentures using a new “sandwich technique” method, before the polymerization process. In the experimental stage, the sample dentures with the new materials were exposed to various damaging environments such as liquid media (sea water, fresh water, alcohol 40%, and HCl 0.2%) in order to test the time resistance of the identification elements. The samples were monitored and tested over four years. (3) Results: the information stored on the NFC tags was retrieved unaltered at the end of the monitoring period, regardless of the damage caused by the liquid media to the sample denture material and will provide an innovative solution as compared to other labeling methods. (4) Conclusion: the use of intelligent materials for labeling acrylic dentures provides additional reliability by preserving the identification information over time.

9 May 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
MAMaria Claudia Albu
Maria Claudia Albu
CȘCorina-Laura Ștefănescu
Corina-Laura Ștefănescu
MRMurineanu Rodica
Murineanu Rodica
MGMircea Grigorian
Mircea Grigorian
LILIANA SACHELARIELILIANA SACHELARIE
LILIANA SACHELARIE
ACAureliana Caraiane
Aureliana Caraiane
(1) Background: The development of advanced dental biomaterials has significantly improved restorative dentistry, shifting the focus from purely mechanical restoration toward materials capable of interacting biologically with oral tissues. Modern restorative materials are expected to demonstrate high biocompatibility, adequate mechanical properties, and potential bioactivity that may support tissue preservation and long-term clinical performance. This review aims to analyze recent advances in next-generation dental restorative materials and to evaluate their biological compatibility and potential clinical relevance. (2) Methods: A narrative literature review was conducted using major scientific databases, including PubMed, Scopus, and Web of Science, focusing on studies addressing advanced polymer-based composites, bioactive restorative materials, dental ceramics, computer-aided design and computer-aided manufacturing (CAD–CAM) restorative systems, and nanostructured biomaterials used in restorative dentistry. Relevant studies published in recent years were analyzed with respect to material composition, biological response, and reported clinical performance. (3) Results: The reviewed literature indicates that modern dental biomaterials, including nanocomposites, bioactive glass-containing materials, calcium silicate–based systems, and hybrid ceramic materials, show improved mechanical stability, enhanced remineralization potential, and reduced bacterial adhesion compared with traditional restorative materials. Advances in nanotechnology and material engineering have also contributed to the development of antimicrobial and bioactive restorative systems. (4) Conclusions: Next-generation dental restorative materials demonstrate promising characteristics that may improve clinical outcomes and biological integration in restorative dentistry; however, further long-term clinical investigations are required to fully confirm their safety, durability, and long-term effectiveness.

3 March 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
LILIANA SACHELARIELILIANA SACHELARIE
LILIANA SACHELARIE
RFRamona Diana Feier
Ramona Diana Feier
CȘCorina-Laura Ștefănescu
Corina-Laura Ștefănescu
MGMircea Grigorian
Mircea Grigorian
MRMurineanu Rodica
Murineanu Rodica
Loredana Liliana HurjuiLoredana Liliana Hurjui
Loredana Liliana Hurjui
(1) Background: Dental implant instability represents a dynamic biomechanical process influenced by functional loading, peri-implant bone stiffness, and systemic conditions affecting bone metabolism. In patients with systemic bone disorders, altered material properties and impaired remodeling may reduce effective implant–bone interface stiffness, potentially increasing micromotion beyond what is detectable by conventional clinical indicators. The aim of this study was to develop and evaluate a predictive bioengineering model of implant instability based on Periotest-derived dynamic measurements. (2) Methods: A retrospective analysis was performed on 79 dental implants placed in patients with and without systemic bone disorders. Implant micromotion was quantified using Periotest values (PTVs). Linear and logistic regression analyses were applied to model the relationship between systemic bone status, implant location, and biomechanical instability (defined as PTV > +2.0). A load–stiffness–micromotion framework was used to provide mechanical interpretation of the findings. (3) Results: Implants placed in patients with systemic bone disorders exhibited significantly higher Periotest values compared to controls (+2.1 ± 1.3 vs. −0.4 ± 1.1; mean difference 2.5 PTV units, 95% CI 1.97–3.04; p < 0.001). High-risk biomechanical instability (PTV > +2.0) was observed in 46% of implants in the systemic group compared to 9% in controls. Multivariable logistic regression demonstrated that systemic bone disorders were independently associated with a 2.6-fold increase in the odds of high-risk instability after adjustment for implant location. The observed instability pattern was consistent with reduced effective peri-implant stiffness in systemically compromised bone. (4) Conclusions: Dental implant instability in systemically compromised patients can be interpreted as a load–stiffness imbalance at the implant–bone interface. The proposed predictive bioengineering framework links dynamic Periotest measurements with mechanical modeling and systemic bone status, enabling quantitative risk stratification beyond static stability assessments.