Saba Gheni

Prof. Saba Gheni


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2015 in Applied Petrochemical Research
Verified
Journal Article
Open access
PDF file
SESameer A. Esmaeel
Sameer A. Esmaeel
SGSaba Gheni
Saba Gheni
AJAysar T. Jarullah
Aysar T. Jarullah
This research aims at developing a discrete kinetic model of the hydrotreating process of a crude oil residue based on experiments. Thus, various experiments were conducted in a continuous flow trickle bed reactor over a temperature range of 653–693 K, liquid hourly space velocity of 0.3–1.0 h−1, and hydrogen pressure of 6.0–10.0 MPas at a constant hydrogen to oil ratio of 1000 L L−1. The reduced crude residue had been assumed to have five lumps: naphtha, kerosene, light gas oil, heavy gas oil and vacuum residue. An optimization technique based on the minimization of the sum of the squared error between the experimental and predicted compositions of the distillate fractions was used to calculate the optimal value of kinetic parameters. The predicted product composition showed good agreement with the experimental data for a wide range of operating conditions with a sum of square errors of less than 5 %.

6 August 2018 in Environmental Processes
Verified
Journal Article
Closed access
PDF file
SGSaba Gheni
Saba Gheni
SASafaa M. R. Ahmed
Safaa M. R. Ahmed
AAAhmed N. Abdulla
Ahmed N. Abdulla
WMWadood T. Mohammed
Wadood T. Mohammed

20 February 2016 in International Journal of Chemical Reactor Engineering
Verified
Journal Article
Closed access
SGSaba Gheni
Saba Gheni
YAYasser I. Abdulaziz
Yasser I. Abdulaziz
Muthanna Al-DahhanMuthanna Al-Dahhan
Muthanna Al-Dahhan
In this investigation, time average local gas holdup and bubble dynamic data were achieved for three L/D ratios of slurry bubble column. The examined ratios were 3, 4 and 5 in 18″ diameter slurry bubble column. Air-water-glass bead system was used with superficial gas velocity up to 0.24 m/s. The gas holdup was measured using four tips optical fiber probe technique. The results showed that the gas holdup increases almost linearly with the superficial gas velocity in 0.08 m/s and levels off with a further increase of velocity. A comparison of the present data with those reported for other slurry bubble column having diameters greater than 18″ and L/D higher than 5 was made. The results indicated a little effect of diameter on the gas holdup. A local, section-averaged gas holdup increases with increasing superficial gas velocity, while the effect of solid loading are less significant than that of the superficial gas velocity. Chaos analysis was used to analyze the slurry system.

13 April 2016 in International Journal of Chemical Reactor Engineering
Verified
Journal Article
Closed access
PDF file
HAHiba A. Abdulkareem
Hiba A. Abdulkareem
SGSaba Gheni
Saba Gheni
RYRafi’ J. Yacoup
Rafi’ J. Yacoup
Bubble columns are widely used for contacting gas–liquid and gas–liquid–solid mass transfer/chemical reactions. Gas distributor is the most important accessory because it decides the bubble size/rise velocity and gas distribution. In this study, the effect of distributor design on hydrodynamics and mass transfer coefficient are studied at different operating conditions of height to diameter ratio, solid loading, and superficial gas velocity The overall gas holdup, is studied experimentally using a rectangular slurry bubble column operating at ambient temperature and pressure, using liquid paraffin (C 9 –C 11 ), three heights to diameter ratios (6, 7.5 and 10) and silica as a solid phase (0 %, 9 % and 25 %) with oxygen as gas phase. Two types of distributor were used, perforated plate and ring type. The results showed that the overall gas holdup increased by increasing gas velocity and decreased by increasing height to diameter ratio and solid loading. Also, it is found that the perforated plate distributor gave a higher gas hold up than ring distributor at gas velocity higher than 0.03 m/sec. The following correlations are obtained: Plate distributor at presence of silica particles: ε g = 1.343 U g 0.0612 − 0.00891 ε s − 0.374 − 0.702 L D 0.041 4.904 − 0.0251 $$\eqalign{{{\rm{\varepsilon}}_{\rm{g}}} =& {\left({1.343{\rm{U}}_{\rm{g}}^{0.0612} - 0.00891{\rm{\varepsilon}}_{\rm{s}}^{- 0.374} - 0.702{{\left({{{\rm{L}} \over {\rm{D}}}} \right)}^{0.041}}} \right)^{4.904}}\cr& - 0.0251}$$ Ring distributor at presence and absence of silica particles: ε g = 0.216 U g 0.297 − 0.354 ε s 1.4671 − 0.127 L D 0.147 1.1206 + 0.058 $$\eqalign{{{\rm{\varepsilon}}_{\rm{g}}} = &{\left({0.216{\rm{U}}_{\rm{g}}^{0.297} - 0.354{\rm{\varepsilon}}_{\rm{s}}^{1.4671} - 0.127{{\left({{{\rm{L}} \over {\rm{D}}}} \right)}^{0.147}}} \right)^{1.1206}} \cr&+ 0.058}$$ There is a good agreement between experimental and predicted values with a percent of error less than 2 %. It has been found that the mass transfer coefficient is higher for ring distributor than the perforated plate and growing higher for heterogeneous flow regime and higher solid loading.

23 October 2018 in Oil & Gas Science and Technology – Revue d’IFP Energies nouvelles
Verified
Journal Article
Open access
SGSaba Gheni
Saba Gheni
MAMohammed F. Abed
Mohammed F. Abed
EHEssam K. Halabia
Essam K. Halabia
SASaad R. Ahmed
Saad R. Ahmed
In this work, mathematical models of carbon dioxide (CO2) absorption by monoethanolamine amine (MEA) in a falling film contactor are developed. The proposed models aim to predict conversion of the gas liquid reaction along the contactor, gas liquid interface temperature profile (axial and radial), liquid film thickness along the contactor length, axial and radial concentration profiles of reactants in liquid film, and axial and radial profiles of velocity in the liquid film. A code written in MatLab was used to obtain these profiles based on multi grid method through programming of kinetic and thermodynamic equations and physical properties of the absorption system. The mathematical model is validated by an experimental measurement based on absorption of CO2 gas by MEA solution. Four parameters are studied as independent variables namely, mole fraction of carbon dioxide in gaseous mixture, molar concentration of absorbent (MEA, volumetric flow rate of MEA, and its temperature. It is found that the entrance effect of the falling film contactor is related to axial distance from the contactor entrance exponentially: E = B(0)exp(-B(1)y) An optimization technique based on minimization of the sum of the squared error between the experimental and predicted composition of absorption process is used to obtain B-0 and B-1. It is found that reaction between carbon dioxide and MEA is instantaneous, and the axial conversion of carbon dioxide in the gas phase varies exponentially with the contactor length.