Patrick Simard

Dr. Patrick Simard

École d'Optométrie, Université de Montréal
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
SVStephen J. Vincent
Stephen J. Vincent
PCPauline Cho
Pauline Cho
KCKa Yin Chan
Ka Yin Chan
DFDaddi Fadel
Daddi Fadel
NGNeema Ghorbani-Mojarrad
Neema Ghorbani-Mojarrad
LJLyndon Jones
Lyndon Jones

1 September 2018 in Eye & Contact Lens: Science & Clinical Practice
Verified
Journal Article
Closed access
RMRémy O.D. Marcotte-Collard
Rémy O.D. Marcotte-Collard
Patrick SimardPatrick Simard
Patrick Simard
LMLangis Michaud
Langis Michaud
Purpose: This study aims to analyze two commercial orthokeratology lens designs and compare their optical effects at the corneal level. Methods: This is a retrospective study on subjects seeking an orthokeratology fitting for myopia management at the Université de Montréal clinic between January 2013 and August 2015. Group A included the first 64 subjects fitted with a 4-curve lens design (Paragon CRT; Paragon) who met the inclusion criteria, whereas group B included the same number of subjects fitted with a 5-curve lens design (Dreamlens; Polymer Technology, Rochester, NY). Topographic tangential maps were collected at baseline and 3 months after fitting. The differential map was generated for each patient and analyzed, which involved determining the radius of the central distance zone (CDZ) and the power and width of the high convex zone (HCZ). Results were compared between the two groups, taking baseline refraction into account. Finally, a correlation was estimated between topographic data and corneal parameters (flat and steep K, the corneal eccentricity of each principal meridian). Results: The CDZ for group A is significantly larger than the one generated for group B both horizontally (t(126)=12.12, P<0.01) and vertically (t(126)=15.690, P<0.01). However, there was no significant difference regarding the HCZ power generated. The only correlations found were a strong positive association between CDZ radius and HCZ power generated by lens A nasally (r=0.450; P=0.000) and temporally (r=0.558; P=0.000), and a weaker association between the baseline refractive error, along with the nasal (r=0.237; P=0.033) and temporal (r=0.288; P=0.028) HCZ power for lens B. Conclusion: The four- and five-curve orthokeratology lens designs generate significantly different optical modifications on the cornea. This can affect reports on orthokeratology efficacy for myopia management as well as the lens selection when used for myopia correction.

27 November 2002
Verified
Conference Paper
Closed access
PHP. Haffner
P. Haffner
LBL. Bottou
L. Bottou
PHP.G. Howard
P.G. Howard
Patrick SimardPatrick Simard
Patrick Simard
YBYoshua BENGIO
Yoshua BENGIO
YCY. Le Cun
Y. Le Cun

10 June 2004
Verified
Conference Paper
Closed access
Patrick SimardPatrick Simard
Patrick Simard
HMH.S. Malvar
H.S. Malvar
JRJ. Rinker
J. Rinker
ERE. Renshaw
E. Renshaw
Many bitmap documents are composed by the superposition of layers withpictures and text. These documents do not compress well using image compressionalgorithms such as JPEG-2000, because text introduces sharp edgeson top of the smooth surfaces typically found in natural images. Similarly,compression algorithms for text facsimiles, such as JBIG2, are not suited forcolor or gray level images. We propose the SLIm system for separating textand line drawing from background images, in order to compress both moreeffectively. This approach differ from previous ones such as DjVu, Tiff-FX,and MRC, by being extremely simple and fast, while yielding close to state-of-the-art compression performance. We present results that show that theSLIm compression performance is attractive for many applications.

6 December 2022 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
ÉLÉric Lortie-Milner
Éric Lortie-Milner
LBLaurence Boily
Laurence Boily
LMLangis Michaud
Langis Michaud
NQNadia-Marie Quesnel
Nadia-Marie Quesnel
Patrick SimardPatrick Simard
Patrick Simard
Patrick BoissyPatrick Boissy
Patrick Boissy

13 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LMLangis Michaud
Langis Michaud
Patrick SimardPatrick Simard
Patrick Simard
RMRémy Marcotte-Collard
Rémy Marcotte-Collard
Mhamed OuzzaniMhamed Ouzzani
Mhamed Ouzzani
LSLoraine T. Sinnott
Loraine T. Sinnott
CONTEXT: Authors have refined myopia control strategies (MCS) from their experience treating more than 800 children who were followed at the Montreal School of Optometry Clinic (CUV). They developed a treatment algorithm known as the Montreal Experience (ME). Contrary to many other MCS, treatment modalities are selected after careful evaluation of a patient’s parameters (rate of progression, age of myopia onset, corneal parameters, pupil area), the risk factors for ocular pathology (growth charts), and taking into account the patient’s lifestyle and potential compliance. This represents a customized approach for each patient. PURPOSE: To evaluate the efficacy of MCS used following ME algorithm; the primary outcome relates to axial length progression over 24 months. METHODS: This is a retrospective study, conducted after approval of University IRB. Data were extracted from the file of each patient who: (1) consulted CUV between January 2017 and December 2018 and (2) were kept under the same MCS (same design/concentration). Clinical population is composed of 298 patients (35% Caucasian; 45% Asian; 20% others), with a median age of 11 (range 5–18). The treatment options were orthokeratology (OK-4 designs; N = 140), multifocal soft contact lenses (SMCL; 5 designs; N = 128), and low-dose atropine (LDA 0.01% to 0.25%; N = 42). RESULTS: Results are analyzed through sophisticated statistical models, designed for this purpose. At the end of a stepwise selection process that sequentially removed model terms that were not statistically significant, nine model terms remained: month, modality, the interaction of month and modality, refraction (SEQ), the interaction of SEQ and modality, gender, age, the interaction of age and month, and the interaction of age and modality. A total of 298 files were kept for analysis. Participant age varied from 9.7 to 12.5 years old. Baseline AL varied from 24.9 to 25.3 mm and SE refraction was −3.7 + 1.7 D on average. This study population was divided between Caucasian (34%), Asian (44%), and other ethnic origins (22%). Overall results indicate that results vary according to modality and months only. There is no statistical difference based on age, gender, and SEQ. All methods used were effective to slow the natural AL growth. Evolution was the lowest when using smaller treatment zones OK lenses (0.249 mm) and the highest (0.376 mm) for those treated with LDA. This OK advantage was statistically significant versus other modalities at 1 and 2 years. CONCLUSION: The Montreal Experience reveals that personalized MCS may be effective to manage myopia efficiently. It shows AL evolution comparable to the documented natural evolution of emmetropes, especially when using customized or smaller treatment zone OK lens design. Future work on other populations will confirm this tendency.